| Ionization Method(s) | ESI, APCI, Dual Ionization | ESI, APCI, Dual Ionization, Micro-ESI | ESI, APCI (optional) | ESI, APCI, Dual Ionization |
| Description | Utilizing patented ultrafast (UF) technology, the LCMS-2020 mass spectrometer offers fast measurements and outstanding detection sensitivity for quicker and more accurate detection of trace impurities in a variety of applications.
Features - Ultrafast scanning speed of 15,000 u/sec, without
Utilizing patented ultrafast (UF) technology, the LCMS-2020 mass spectrometer offers fast measurements and outstanding detection sensitivity for quicker and more accurate detection of trace impurities in a variety of applications.
Features - Ultrafast scanning speed of 15,000 u/sec, without sacrificing sensitivity or resolution
- Unsurpassed 15 msec polarity switching speed, for the most data without peak deterioration in a single injection
- Multiple Ionization options – ESI, APCI, and DUIS
- Dual Ion Source – truly enables simultaneous ESI and APCI analysis
- Easy system maintenance – enables greater uptime and usability
- Innovative ion optics—provide greater sensitivity than any other single quadrupole analyzer
- Backwards compatible – no need to upgrade your HPLC
The ESI method typically used for LCMS can be replaced with APCI, which is suitable for neutral compounds, or with a dual ionization source (DUIS) for simultaneous operation of both ionization modes, quickly and without tools. Selection of the DUIS ionization mode (ESI or APCI) can be performed via the computer. In addition, the desolvation line, where the ions enter the MS unit, can be replaced without breaking vacuum.... Read More | The triple quad LCMS-8060RX utilizes proprietary technologies and more efficient ion transfer to achieve outstanding speed and sensitivity.
A heat-assisted electrospray ionization probe delivers a highly efficient desolvation process that promotes the ionization of a wide range of target compounds The triple quad LCMS-8060RX utilizes proprietary technologies and more efficient ion transfer to achieve outstanding speed and sensitivity.
A heat-assisted electrospray ionization probe delivers a highly efficient desolvation process that promotes the ionization of a wide range of target compounds while the systems unique IonFocus™ electrode efficiently delivers ions into the mass spectrometer, resulting in lower noise levels, superior data quality and reduced maintenance needs.
Additional features include:
- CoreSpray™ gas delivery system – enhances reliability by increasing gas flow and improving nebulizer coaxiality.
- Ultrafast high-voltage power supply – enables sensitive and stable signal detection
- UFsweeper Collision Cell – delivers fast and accurate MRM quantitation; high-speed and high-efficiency CID occurs as ions are accelerated through the cell, enabling multi-component analysis with little signal degradation or crosstalk
- Scan speed of 30,000 u/s
- 5 ms polarity switching time
- Ultra-fast MRM measurements up to 555 ch/sec
- IonFocus™ electrode – effectively removes matrix contaminants, resulting in lower noise levels, superior data quality and reduced maintenance needs
- Easy maintenance – Consumable parts like the ESI spray needle and the inlet desolvation line (DL) can be changed quickly and easily without breaking vacuum.
- Performance Concierge – Automatically monitors system performance, provides proactive maintenance alerts, and reduces instrument downtime through predictive diagnostics.
LabSolutions LCMS workstation software offers total operator support, from analysis to data processing.
The LabSolutions Connect/LabSolutions Insight platform supports the entire analysis workflow, including:
- Project file management
- Optimization of MRM and interface parameters
- Efficient verification of quantitative results
- Simple method and batch creation
- Verification of quantitative results
... Read More | The LCMS-8065XE introduces innovative technologies that deliver exceptional performance with evolved, efficient and exact capabilities.
The instrument incorporates Shimadzu’s complete Ultra Fast Mass Spectrometry (UFMS) technology suite:
- World-class 5 msec positive/negative ion switching with
The LCMS-8065XE introduces innovative technologies that deliver exceptional performance with evolved, efficient and exact capabilities.
The instrument incorporates Shimadzu’s complete Ultra Fast Mass Spectrometry (UFMS) technology suite:
- World-class 5 msec positive/negative ion switching with zero signal loss
- Ultra-fast MRM acquisition up to 555 channels/sec
- Scanning up to 30,000 u/sec with maximum ion transmittance
- Advanced UF-Qarray™II & UF-Lens™ II ion guides for maximum transmission efficiency
New advancements include:
- StreamFocus Ionization Technology – The LCMS-8065XE features a low-dispersion nebulizer nozzle that dramatically reduces liquid droplet dispersion while maximizing ion intake efficiency. This breakthrough reduces nebulizer gas consumption by up to 7-fold compared to conventional ESI sources and achieves exceptional sensitivity improvements, particularly in negative mode.
- Enhanced IonFocus Performance – The evolved IonFocus unit utilizes a focusing electrode to selectively guide ions into the intake port while excluding neutral matrix components. This ensures sensitivity even when the ion spray is positioned further from the intake port, delivering superior robustness for long-term analysis.
- UFsweeper™ IV Collision Cell – The next-generation collision cell features a larger inlet lens diameter and an increased number of lenses for improved ion throughput, enhanced ion transmission, and dramatically improved sensitivity and quantitative precision.
- Performance Concierge – Automatically monitors system performance, provides proactive maintenance alerts, and reduces instrument downtime through predictive diagnostics. Peakintelligence for LCMS delivers revolutionary AI-driven peak detection with up to 67% reduction in manual review time and superior reproducibility across complex analyses.
The LCMS-8065XE excels across environmental monitoring, food safety, pharmaceutical analysis, clinical research, and industrial quality control applications.
It particularly excels for analysis of PFAS.
The LCMS-8065XE demonstrates remarkable capabilities with sub-ng/L detection limits for PFAS compounds in drinking water using direct injection.
The system delivers 3–48 fold sensitivity enhancement compared to previous generation instruments while maintaining exceptional stability – over 85% of initial response retained after more than 10,000 consecutive injections of complex wastewater samples (RSD <7%)
LabSolutions LCMS workstation software offers total operator support, from analysis to data processing.
The LabSolutions Connect/LabSolutions Insight platform supports the entire analysis workflow:
- Project file management
- Optimization of MRM and interface parameters
- Efficient verification of quantitative results
- Simple method and batch creation
- Verification of quantitative results
... Read More | The Nexera QX Multiplex LC-MS/MS System uses multiple, alternating sample introduction streams for continuous operation of the mass spectrometer to significantly increase laboratory throughput and profitability.
- Multiple stream technology eliminates waiting for column equilibration and system
The Nexera QX Multiplex LC-MS/MS System uses multiple, alternating sample introduction streams for continuous operation of the mass spectrometer to significantly increase laboratory throughput and profitability.
- Multiple stream technology eliminates waiting for column equilibration and system flushing
-
UHPLC autosamplers, stream-dedicated injection valves and washing pumps deliver ultra-fast performance with ultra-low carryover
-
Automates flow line rinsing of each analytical stream to mitigate carryover from extreme samples
-
Online sample cleanup – Automated online sample preparation avoids errors caused by manual handling and maximizes throughput.
-
Multiple configurations available
-
Utilizes the LCMS-8060NX triple quadrupole mass spectrometer, which delivers industry-leading robustness, sensitivity and detection speeds.
Dedicated QX Solution software offers a single point of control for multiple UHPLC streams and the mass spectrometer. By incorporating Analytical Intelligence, such as automatic carryover detection and evaluation, automatic rinsing, and high-concentration automatic detection, QX software ensures robust operation for prolonged unattended analysis.... Read More |