LC MS Instrument

Comprising two components, a liquid-phase separation system and a mass spectrometer, liquid chromatograph mass spectrometers (LC MS instruments) couple sample fractionation and analysis. The separation can be accomplished via standard liquid chromatography, HPLC, UPLC, or even nano-LC. Any liquid-phase separation will do, so long as its output can be directed into the mass analyzer (for instance, via an electrospray ionization source). The mass spectrometer is similarly flexible, ranging from the simplest single quadrupole to a Fourier transform ion cyclotron resonance instrument. Just remember, in a liquid chromatograph mass spectrometer the column flow is continuous, meaning the mass analyzer must be fast enough to thoroughly analyze one peak before the next one comes off the column. And, unlike with MALDI MS, once a peak is analyzed, it’s gone.
CompanySCIEXSCIEXSCIEXSCIEXSCIEX
ItemSCIEX Triple Quad 7500 systemEcho® MS systemIntabio ZT systemSelexION Differential Mobility SpectrometryZenoTOF 7600 system
Citations
(1)
(7)
Catalog NumberSCIEX Triple Quad 7500Echo MSIntabio ZTSelexIONZenoTOF 7600
Price
Ionization Method(s)OptiFlow® Pro Ion SourceElectrospray IonizationInquireInquireAPCI and ESI modes
Mass AnalyzerTriple quadrupoleInquireInquireInquireTOF
Scanning Speed20,000 Da/sUp to 3 samples per secondInquireInquireup to 25 Hz (25 spectra per second)
ResolutionUp to 3100 for mass 922 in LIT mode 1000 Da/s (0.3 Da)
Tune to a peak width of 0.5 Da for TQ mode
InquireInquireInquireEqual to or greater than 42,000 (FWHM) measured on the [M+6H]6+ charge isotope cluster for bovine insulin at m/z 956
DescriptionIncomparable: Experience extraordinary sensitivity gains from the SCIEX 7500 system. Start detecting the previously undetectable, and quantify at lower levels with impressive precision.

Ingenious: Expand your laboratory capabilities to test dirty and complex samples. The new D Jet ion guide will
... Read More
This ultra-high sample throughput system for Acoustic Ejection Mass Spectrometry (AEMS) delivers speed, scale and reproducibility with unyielding data quality. The Echo® MS System leverages industry leading quantitative MS technology from SCIEX to deliver a highly sensitive solution that can ... Read MoreThe Intabio ZT system couples icIEF separation and UV detection with high-resolution mass spectrometry on the ZenoTOF 7600 system. Experience one integrated workflow with a single, accessible dataset containing the required information to make the right decisions, fast.

Features
  • Comprehensive
... Read More
LC-MS/MS assay development can be challenging, particularly for analytes that coelute with contaminants or become buried within background noise. The SCIEX SelexION Differential Mobility Separation device (DMS) provides an extra level of selectivity so you can resolve difficult analytes and achieve ... Read MoreA powerful leap in proprietary innovation, this high-resolution accurate mass system combines the power of Zeno trap pulsing with EAD fragmentation technology (electron activated dissociation) to uncover structural information, previously inaccessible, and drive the limits of quantification ... Read More
QuantityEAEAEAInquireEA
TypeLC-MS/MSInquireInquireInquireInquire
Get Quote

Articles