The Orbitrap, also known as the Kingdon trap, is a type of ion trap mass analyzer employed by certain lines of mass spectrometers. Compared to its other ion trap mass analyzers, the way the orbitrap works is based upon the ion trajectories as they move through the electrode, which follow an orbital path. Ionization can vary by the system, but commonly includes atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI).
Search and compare Orbitrap Mass Spectrometers
|  |  |  |  |  |
| Company | Thermo Fisher Scientific | Thermo Fisher Scientific | Thermo Fisher Scientific | Thermo Fisher Scientific | Thermo Fisher Scientific |
| Item | Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer | Orbitrap Exploris™ GC 240 Mass Spectrometer | Orbitrap IQ-X™ Tribrid™ Mass Spectrometer | Orbitrap™ Astral™ Mass Spectrometer | Thermo Scientific™ Orbitrap Exploris™ MX mass detector |
| Citations | | | | | |
| Catalog Number | IQLAAEGAAPFADBMBHQ | IQLAAAGABPFARJMBLY | IQLAAEGAAPFADBMBMA | IQLAAEGAAPFARYMBOB | IQLAAEGAAPFARBMBMS |
| Price | | | | | |
| Ionization Method(s) | HESI | EI/PCI/NCI | ESI | Adjustable heated electrospray ionization (HESI) probe | Inquire |
| Mass Analyzer | Orbitrap | High-field Orbitrap mass analyzer | Orbitrap | Orbitrap mass analyzer ranging from 7,500 to 480,000 resolution at m/z 200
Astral mass analyzer is operated at a single resolution setting of 80,000 at m/z 524 | Inquire |
| Scanning Speed | Inquire | Up to 40 Hz at resolution setting 7,500 at m/z 200 | Inquire | Up to 200 Hz | Inquire |
| Mass Range | m/z 50–2,000
m/z 200–4,000
up to m/z 6,000 without precursor ion selection (OTMS only) | m/z 30 to 3,000 | 50 to 2000 m/z | Maximum Astral mass analyzer resolution up to 80,000 FWHM at m/z 524
Maximum Orbitrap mass analyzer resolution of up to 480,000 FWHM at m/z 200 | Inquire |
| Description | Excel at the most challenging of applications, including low level PTM analysis, multiplexed relative quantitation using isobaric tags, intact protein characterization, as well as MSn analysis of small molecules with the new Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer. ThisExcel at the most challenging of applications, including low level PTM analysis, multiplexed relative quantitation using isobaric tags, intact protein characterization, as well as MSn analysis of small molecules with the new Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer. This system incorporates the brightest ion source, a segmented quadrupole mass filter with improved selectivity and ion transmission, Advanced Vacuum Technology for improved ion transmission to the Thermo Scientific™ Orbitrap™ mass analyzer, and ETD HD, a higher-capacity ETD fragmentation. Latest innovations include the Advanced Peak Determination (APD) algorithm for improved data-dependent experiments and two new hardware options: UVPD, a new fragmentation technique achieved with a 213 nm UV laser and 1M, which provides 1,000,000 FWHM ultra-high resolution for improved structural elucidation and quantitation of isobaric compounds.... Read More | The Orbitrap Exploris GC 240 takes research capability to a new and unprecedented level of performance to accelerate scientific discovery. With a unique ability to deliver the very highest data quality, the most complex analytical challenges are simplified. By delivering uncompromising qualitative The Orbitrap Exploris GC 240 takes research capability to a new and unprecedented level of performance to accelerate scientific discovery. With a unique ability to deliver the very highest data quality, the most complex analytical challenges are simplified. By delivering uncompromising qualitative and quantitative performance, the system provides the flexibility to address the demands of scientific research laboratories for compound identification and quantitation. From discovery profiling, metabolomics and applied quantification, scientists gain unparalleled access to information rich data and results with ease.... Read More | Built for small-molecule analyses, the Thermo Scientific™ Orbitrap IQ-X™ Tribrid™ mass spectrometer reveals your most complex chemical structures? with ultimate confidence, ease, and experimental versatility. | Inquire | Accelerate biopharmaceutical late-stage development, commercialization, manufacturing, and quality control (QC) by easily and reliably obtaining compliance-ready, high-quality mass information.
The Thermo Scientific Orbitrap Exploris MX mass detector is the perfect fit for deploying routine mass Accelerate biopharmaceutical late-stage development, commercialization, manufacturing, and quality control (QC) by easily and reliably obtaining compliance-ready, high-quality mass information.
The Thermo Scientific Orbitrap Exploris MX mass detector is the perfect fit for deploying routine mass monitoring.
In addition to high-resolution mass detection provided by Thermo Scientific Orbitrap mass analyzers, this fit for purpose system is simple to operate and compliance ready with Thermo Scientific Chromeleon chromatography data system (CDS) software. Consistent performance between the Thermo Scientific Orbitrap Exploris 240 mass spectrometer and Orbitrap Exploris MX detector ensures seamless method transfer from development to QC.... Read More |
| Get Quote | | | | | |