| Company | Nu Instruments | Nu Instruments |
| Item | Nu Plasma 1700 HR-MC-ICP-MS | Nu Sapphire MC-ICP-MS |
| Price | Inquire | Inquire |
| Description | Nu Plasma 1700 is a large-geometry, double-focusing HR-MC-ICP-MS with ~1,700 mm mass dispersion. The large geometry raises the base resolving power to >800 (10% valley definition) at full sensitivity, and edge resolving power reaches >30,000 (5–95% edge definition) by narrowing the continuously Nu Plasma 1700 is a large-geometry, double-focusing HR-MC-ICP-MS with ~1,700 mm mass dispersion. The large geometry raises the base resolving power to >800 (10% valley definition) at full sensitivity, and edge resolving power reaches >30,000 (5–95% edge definition) by narrowing the continuously adjustable source entrance slit. Each of the 16 Faraday detectors and up to 5 ion-counting detectors carries an independently adjustable high-resolution collector slit, enabling simultaneous true high-resolution operation across the entire array.... Read More | Nu Sapphire is a dual-path MC-ICP-MS that combines a double-focusing magnetic sector mass analyser with a hexapole collision/reaction cell on a separate low-energy ion path (patented GB 2535826). The high-energy path provides classical MC-ICP-MS operation; the low-energy path decelerates ions into Nu Sapphire is a dual-path MC-ICP-MS that combines a double-focusing magnetic sector mass analyser with a hexapole collision/reaction cell on a separate low-energy ion path (patented GB 2535826). The high-energy path provides classical MC-ICP-MS operation; the low-energy path decelerates ions into the hexapole CRC for removal of Ar-based and polyatomic interferences. Variable-dispersion Zoom Optics allow instantaneous switching between collector configurations.... Read More |
| Optical System | Double-focusing large-geometry MC-ICP-MS; ~1,700 mm mass dispersion; continuously adjustable source entrance slit; independently adjustable high-resolution collector slit per detector; base resolving power >800 (10% valley); peak-flat resolving power >5,000; edge resolving power >30,000 (5–95% edge); Enhanced Sensitivity Interface as standard; variable-dispersion Zoom Optics; optional EATO; optional hexapole collision/reaction cell (Sapphire 1700 variant) with dual-path transfer optics | Double-focusing magnetic sector; dual-path transfer optics (high-energy path for classical MC-ICP-MS; low-energy path with hexapole collision/reaction cell, patented GB 2535826); variable-dispersion Zoom Optics; Enhanced Sensitivity Interface as standard; up to 4 independently controlled reaction gas inlets |
| Mass Analyzer | Multi-collector double-focusing magnetic sector; 16 Faraday cups + up to 5 ion-counting detectors (SEM or Daly); mass range lithium to actinide series | Multi-collector double-focusing magnetic sector; 16 Faraday cups + up to 6 ion-counting detectors (SEM or Daly); high-resolution and pseudo-high-resolution modes |
| Applications | High-resolution isotope ratio analysis, non-traditional stable isotopes (Mg, Si, S, K, Ca, Ti, V, Cr, Fe, Ni, Se), geochronology, geochemistry, cosmochemistry, nuclear research, life sciences | Non-traditional stable isotope analysis (Mg, Si, S, K, Ca, Ti, V, Cr, Fe, Ni, Se), geochemistry, cosmochemistry, life sciences, nuclear research |
| Get Quote | Inquire | Inquire |