Description | Free your ICP-MS analysis with the Agilent 7850 ICP mass spectrometer from common time traps. It’s the smart way to reduce wasted time so busy staff can focus on tasks that deliver value. The 7850 ICP-MS is an ICP mass spectrometer that can handle samples with up to 25% solids, reducing the dilutionFree your ICP-MS analysis with the Agilent 7850 ICP mass spectrometer from common time traps. It’s the smart way to reduce wasted time so busy staff can focus on tasks that deliver value. The 7850 ICP-MS is an ICP mass spectrometer that can handle samples with up to 25% solids, reducing the dilution time trap. The instrument features a helium mode collision cell and half mass correction that removes both polyatomic and doubly charged ion interferences, simplifying method development and addressing a common cause of time-wasting sample remeasurement.
Check out how the Agilent 7850 ICP mass spectrometer boosts lab efficiency and helps reclaim wasted time throughout your ICP-MS analysis.
Features- Standard operating procedures and fully developed methods for regulated and routine methods save you weeks of method development and documentation time.
- Ultra High Matrix Introduction (UHMI) reduces sample preparation time by allowing you to directly analyze samples containing up to 25% total dissolved solids without dilution.
- Helium collision cell and half-mass correction remove troublesome polyatomic and doubly-charged interferences that can reduce data quality and increase the need for costly sample remeasurements.
- Robust hardware allows you to measure high matrix samples without having to matrix-match calibration standards.
- IntelliQuant gives you a complete elemental profile of each sample, helping you to easily identify unusual sample matrices.
- Outlier Conditional Formatting (OCF) reduces data review times for busy or inexperienced ICP-MS operators by highlighting results that are outside a nominated range or have failed a test requirement.
- Early Maintenance Feedback (EMF) uses sensors and counters to determine when maintenance is needed. Traffic light, color-coded alerts means maintenance tasks are never missed but are also not performed more frequently than necessary.
- ICP Go is an optional, browser-based user-interface for mobile devices offering simplified set up and control of routine sample batches and is great for ICP-MS operators on the move.
- Method-specific Analyzer packages containing ICP-MS hardware, software, consumables, professional services and documentation ensure you’ll be running samples in weeks, instead of the months it can take to develop, optimize, verify and document a regulated method.
... Read More | The Agilent 7900 ICP-MS is a flexible single quadrupole ICP mass spec instrument that provides the industry’s best matrix tolerance, most effective helium collision mode, lowest detection limits, and widest dynamic range. As a result, you can be confident you are reporting accurate data every time, The Agilent 7900 ICP-MS is a flexible single quadrupole ICP mass spec instrument that provides the industry’s best matrix tolerance, most effective helium collision mode, lowest detection limits, and widest dynamic range. As a result, you can be confident you are reporting accurate data every time, even at trace levels, whatever your sample types.
The 7900 ICP Mass Spec provides the highest performance for demanding commercial and industrial applications, with the high sensitivity and fast acquisition of transient signals – necessary for the analysis of single nanoparticles (spICP-MS), single cells, and for laser ablation. In addition, having the flexibility needed for research and advanced analysis, such as speciation, is sure to give you an edge over the competition.
Features- The industry’s most robust (low CeO/Ce) plasma delivers unprecedented matrix tolerance
- Ultra High Matrix Introduction (UHMI) technology enables you to run samples with 25% total dissolved solids (TDS)
- Helium (He) cell gas mode improves accuracy by providing reliable control of polyatomic interferences
- Off-axis lens provides high sensitivity and low detection limits across the mass range
- Wide dynamic range detector allows you to measure majors and trace in one run
- Fast integration (0.1 ms dwell time) supports analysis of fast transient signals such as single nanoparticles (spICP-MS)
- ICP-MS MassHunter Method Wizard builds your methods automatically
- Flexible configuration easily connects to optional accessories and peripherals for advanced applications
... Read More | The Agilent 8900 triple quadrupole ICP-MS (ICP-QQQ) is the world’s most successful and widely used tandem ICP mass spectrometer. Available in a range of configurations to cover applications from routine contract analysis to advanced research and high-purity materials analysis, the Agilent 8900 ICP-The Agilent 8900 triple quadrupole ICP-MS (ICP-QQQ) is the world’s most successful and widely used tandem ICP mass spectrometer. Available in a range of configurations to cover applications from routine contract analysis to advanced research and high-purity materials analysis, the Agilent 8900 ICP-QQQ redefines ICP-MS performance, delivering results you can trust.
The 8900 offers the same matrix tolerance and robustness as Agilent’s market-leading single quadrupole ICP-MS systems, combined with the industry’s most effective helium (He) collision mode. But the 8900 adds tandem mass spec operation (ICP-MS/MS) for unmatched control of reaction chemistry in the collision reaction cell (CRC), making it the world’s most powerful and flexible multi-element analyzer. Let the 8900 ICP-QQQ take control of your interferences and put your results beyond doubt.
Features- MS/MS controls the reaction chemistry ensuring consistent, reliable results, even for previously difficult elements like Si, P, and S
- Reaction chemistry resolves isobaric overlaps, which are beyond the capability of high-resolution ICP-MS
- Four-channel cell gas control provides fast, flexible, multi-mode operation
- A suite of pre-set methods simplifies method setup for routine analysis
- Helium mode provides simple, effective control of common polyatomic interferences
- Robust (low CeO/Ce) plasma for unmatched matrix tolerance
- Ultra High Matrix Introduction (UHMI) technology tolerates samples with up to 25% total dissolved solids (TDS)
- High sensitivity and low background provide the lowest detection limits for ultra trace analytes
- Versatility and high performance combine to support advanced research and demanding applications
- Flexible modes of operation (precursor/product ion scan) support research into reaction chemistry modes
... Read More |
Applications | Inquire | Multielement analysis in practically all industries from food safety, environmental monitoring, and pharmaceutical testing, to semiconductor manufacturing, geochemical analysis, and life science research | Demanding applications that cannot be run well enough using single quadrupole ICP-MS. These applications may require extremely low detection limits, for example measuring ultra-trace contaminants in semiconductor process chemicals and high-purity materials or detecting the smallest nanoparticles. To resolve isobaric, doubly charged, and adjacent mass overlaps as well as intense polyatomic interferences. This capability allows low-level analysis of unusual analytes such as Si, P, S, Cl, and even F. |