Material and petrochemical research utilizes a wide range of lubricant testing equipment to test lubricant flashpoint, viscosity, purity, volatility, cold properties, Noack as well as other oxidation tests. Essential to modern machinery, lubricant testing equipment is necessary to ensure predetermined standards are met and utilize methods like FTIR. Key considerations are primarily directed by application parameters, measurement time, sample volume and footprint.
|  |  |  |  |  |
| Company | eralytics GmbH | eralytics GmbH | eralytics GmbH | eralytics GmbH | eralytics GmbH |
| Item | ERASPEC Oil Lubricant Monitor | ERACHECK ECO Oil-in-Water Tester | ERADENS X High-precision Density Meter | ERAFLASH Flash Point Tester | ERAVAP Vapor Pressure Tester |
| Reviews | | | | | |
| Catalog Number | EO10 | ECO01 | ERADENS X | EF10 | EV10 |
| Price | | | | | |
| Description | The Latest Trend in Oil Condition Monitoring
ERASPEC OIL is a portable, stand-alone infrared analyzer for high-speed lubricant analysis and condition monitoring in full compliance with ASTM, DIN and JOAP methods. Its patented interferometer design delivers laboratory-grade results directly on site.The Latest Trend in Oil Condition Monitoring
ERASPEC OIL is a portable, stand-alone infrared analyzer for high-speed lubricant analysis and condition monitoring in full compliance with ASTM, DIN and JOAP methods. Its patented interferometer design delivers laboratory-grade results directly on site.
Features
- Monitoring of degradation, additive depletion and contaminants within seconds
- Direct trending and spectral substraction analysis method
- ASTM, DIN and JOAP methods
- Option: Diesel fuel analysis
- ASTM D5845, D6277, D7806, E2412, D4052, etc
... Read More | Eco-Efficient Oil-in-Water Testing
The CFC-free oil-in-water tester ERACHECK ECO easily measures the concentration of total oil and grease (TOG) and total petroleum hydrocarbons (TPH) in water and soil with sub-ppm precision. They deliver consistent results over a wide range of crude types using Eco-Efficient Oil-in-Water Testing
The CFC-free oil-in-water tester ERACHECK ECO easily measures the concentration of total oil and grease (TOG) and total petroleum hydrocarbons (TPH) in water and soil with sub-ppm precision. They deliver consistent results over a wide range of crude types using the CFC-free solvent cyclohexane for the extraction.
Features
- Measurement based on a non-dispersive IR transmission technology (D8193)
- MDL of 0.5 mg/L
- No loss of light ends of samples
- Easy creation of user calibrations
- ASTM D8193, D7678, D7066, ISO9377, EPA 1664
... Read More | ERADENS X is the world’s smallest and lightest high-precision density meter measuring in full compliance with ASTM D4052 and ISO 12185. Its revolutionary vertically aligned x-oscillating metal U-tube design is extremely reliable and insensitive to toughest ambient conditions, making ERADENS X the ERADENS X is the world’s smallest and lightest high-precision density meter measuring in full compliance with ASTM D4052 and ISO 12185. Its revolutionary vertically aligned x-oscillating metal U-tube design is extremely reliable and insensitive to toughest ambient conditions, making ERADENS X the perfect solution for density testing in stationary as well as in mobile laboratories.
Features:
- Large industry-proven color touchscreen
- Unique sample introduction from the top, equally easy to operate for right-handed and left-handed persons
- Corrosion-resistant, extremely robust aluminum housing
- Compact dimensions and lightweight instrument design
- The x-oscillating metal U-tube technology inside, provides density results with 5-digit precision
- Full range viscosity correction ensures highest possible accuracy over the wide temperature range of 0 – 100 °C.
- Patented FillingProof™ Technology for the verification of the bubble-free filling
... Read More | The Safe Side of Flash Point Testing
ERAFLASH with the inherently safe Continuously Closed Cup method guarantees maximum safety and speed. The small volume of 1-2 mL makes ERAFLASH ideal for various applications like fuels, lube oils, paints, flavors & fragrances and many more. ERAFLASH covers The Safe Side of Flash Point Testing
ERAFLASH with the inherently safe Continuously Closed Cup method guarantees maximum safety and speed. The small volume of 1-2 mL makes ERAFLASH ideal for various applications like fuels, lube oils, paints, flavors & fragrances and many more. ERAFLASH covers an unprecedented temperature range from -25 °C to 420 °C (-13 °F to 788 °F).
- No open ignition source
- Only 1-2 mL sample needed
- PBT - Peltier Boost TechnologyTM for maximum speed & range
- Built-in Quality Control Mode
- Heat-insulated cup holder
- ASTM D7094, D6450, D93c, D56c, IP620, etc.
... Read More | Vapor Pressure Testing at its Best
The versatile ERAVAP is the most accurate and reliable vapor pressure testers on the market, always compliant with the latest international standards. With the optional ultra-light temperature-controlled U-tube density meter module DENS4052 (patent pending) Vapor Pressure Testing at its Best
The versatile ERAVAP is the most accurate and reliable vapor pressure testers on the market, always compliant with the latest international standards. With the optional ultra-light temperature-controlled U-tube density meter module DENS4052 (patent pending) ERAVAP offers simultaneous measurement of vapor pressure and density in a single, portable analyzer.
Features
- Unmatched precision & accuracy (r=0.15 kPa / R=0.5 kPa)
- Widest temperature range of - 20 °C to 120 °C (-4 °F to 248 °F)
- Built-in high precision D4052 density meter
- Pressure range from 0 kPa to 2 000 kPa (0 psi to 290 psi)
- True portability for field use
- ASTM D5191, D6378, D5188, D6377, D4052, etc
... Read More |
| Method | FTIR | Inquire | Inquire | Inquire | Inquire |
| Temperature Range | Inquire | Inquire | Inquire | Inquire | Inquire |
| Dimensions | (WxDxH) 29 x 35 x 34 cm (or 11.4 x 13.8 x 13.4 in) | Inquire | Inquire | Inquire | (WxDxH) 29 x 35 x 34 cm (or 11.4 x 13.8 x 13.4 in) |
| Type | Portable lubricant monitor for analysis of degradation, contamination and various calculated properties | Inquire | Density Meter | (Modified) Continuously Closed Cup | Mini Method |
| Measuring Time | 60 to 120 seconds | Inquire | Inquire | Inquire | Inquire |
| Sample Volume | 10 ml | Typically 900 mL water and 50 mL cyclohexane (min. 10 mL solvent required per measurement) | 2 mL | Inquire | Inquire |
| Get Quote | | | | | |