Material and petrochemical research utilizes a wide range of lubricant testing equipment to test lubricant flashpoint, viscosity, purity, volatility, cold properties, Noack as well as other oxidation tests. Essential to modern machinery, lubricant testing equipment is necessary to ensure predetermined standards are met and utilize methods like FTIR. Key considerations are primarily directed by application parameters, measurement time, sample volume and footprint.
|  |  |  |  |  |
| Company | eralytics GmbH | eralytics GmbH | eralytics GmbH | eralytics GmbH | eralytics GmbH |
| Item | ERASPEC Oil Lubricant Monitor | ERACHECK ECO Oil-in-Water Tester | ERACOUNT XS Laser Particle Counter | ERAFLASH LT Flash Point Tester | ERAVAP Vapor Pressure Tester |
| Catalog Number | EO10 | ECO01 | ERACOUNT XS | EF02 | EV10 |
| Price | | | | | |
| Description | The Latest Trend in Oil Condition Monitoring
ERASPEC OIL is a portable, stand-alone infrared analyzer for high-speed lubricant analysis and condition monitoring in full compliance with ASTM, DIN and JOAP methods. Its patented interferometer design delivers laboratory-grade results directly on site.The Latest Trend in Oil Condition Monitoring
ERASPEC OIL is a portable, stand-alone infrared analyzer for high-speed lubricant analysis and condition monitoring in full compliance with ASTM, DIN and JOAP methods. Its patented interferometer design delivers laboratory-grade results directly on site.
Features
- Monitoring of degradation, additive depletion and contaminants within seconds
- Direct trending and spectral substraction analysis method
- ASTM, DIN and JOAP methods
- Option: Diesel fuel analysis
- ASTM D5845, D6277, D7806, E2412, D4052, etc
... Read More | Eco-Efficient Oil-in-Water Testing
The CFC-free oil-in-water tester ERACHECK ECO easily measures the concentration of total oil and grease (TOG) and total petroleum hydrocarbons (TPH) in water and soil with sub-ppm precision. They deliver consistent results over a wide range of crude types using Eco-Efficient Oil-in-Water Testing
The CFC-free oil-in-water tester ERACHECK ECO easily measures the concentration of total oil and grease (TOG) and total petroleum hydrocarbons (TPH) in water and soil with sub-ppm precision. They deliver consistent results over a wide range of crude types using the CFC-free solvent cyclohexane for the extraction.
Features
- Measurement based on a non-dispersive IR transmission technology (D8193)
- MDL of 0.5 mg/L
- No loss of light ends of samples
- Easy creation of user calibrations
- ASTM D8193, D7678, D7066, ISO9377, EPA 1664
... Read More | The Fastest ISO 4406 Laser Particle Counter RACOUNT XS is the smallest and fastest field particle counter. At the push of a button, the laser-based analyzer measures and displays the ISO 4406 particle size channels ≥ 4 µm(c), ≥ 6 µm(c) and ≥ 14 µm(c) – all within 60 seconds using The Fastest ISO 4406 Laser Particle Counter RACOUNT XS is the smallest and fastest field particle counter. At the push of a button, the laser-based analyzer measures and displays the ISO 4406 particle size channels ≥ 4 µm(c), ≥ 6 µm(c) and ≥ 14 µm(c) – all within 60 seconds using only 10 mL of sample.
Your features at a glance:
- 10mL sample volume
-
Measurement up to 8 different size channels when connected to one of eralytics’ other OCM analyzers.
-
Flow rate 10 ml/min
-
Robust, full-metal device with only 3 kg of weight
-
Ideal for many applications: hydraulic & lube oils, fuels
... Read More | The cool side of flash point testing
ERAFLASH LT is based on the unrivaled high performance of the other ERAFLASH flash point testers. However, it offers new benefits for fast low temperature flash point testing. Its enhanced cooling system allows decreasing the measurement temperature down to 35 °C The cool side of flash point testing
ERAFLASH LT is based on the unrivaled high performance of the other ERAFLASH flash point testers. However, it offers new benefits for fast low temperature flash point testing. Its enhanced cooling system allows decreasing the measurement temperature down to 35 °C below the ambient temperature without any external cooling. In addition it is the first flash point tester on the market that allows to use ASTM D7094 down to -40 °C (-40 °F) oven temperature with external cooling.
Features: - Maximum safety – no flame, no glowing wires, no fire hazard
- Cost efficient measurement by using just 1 or 2 mL sample
- Low temperature flash point testing between -40 and 120 °C (-40°F – 248°F) oven temperature
- High-speed measurements at low temperatures using a stacked Peltier design
- Compact and easy-to-use stand-alone analyzer with easy LIMS integration
... Read More | Vapor Pressure Testing at its Best
The versatile ERAVAP is the most accurate and reliable vapor pressure testers on the market, always compliant with the latest international standards. With the optional ultra-light temperature-controlled U-tube density meter module DENS4052 (patent pending) Vapor Pressure Testing at its Best
The versatile ERAVAP is the most accurate and reliable vapor pressure testers on the market, always compliant with the latest international standards. With the optional ultra-light temperature-controlled U-tube density meter module DENS4052 (patent pending) ERAVAP offers simultaneous measurement of vapor pressure and density in a single, portable analyzer.
Features
- Unmatched precision & accuracy (r=0.15 kPa / R=0.5 kPa)
- Widest temperature range of - 20 °C to 120 °C (-4 °F to 248 °F)
- Built-in high precision D4052 density meter
- Pressure range from 0 kPa to 2 000 kPa (0 psi to 290 psi)
- True portability for field use
- ASTM D5191, D6378, D5188, D6377, D4052, etc
... Read More |
| Method | FTIR | Inquire | Inquire | Inquire | Inquire |
| Dimensions | (WxDxH) 29 x 35 x 34 cm (or 11.4 x 13.8 x 13.4 in) | Inquire | Inquire | Inquire | (WxDxH) 29 x 35 x 34 cm (or 11.4 x 13.8 x 13.4 in) |
| Type | Portable lubricant monitor for analysis of degradation, contamination and various calculated properties | Inquire | Laser Particle Counter | (Modified) Continuously Closed Cup | Mini Method |
| Measuring Time | 60 to 120 seconds | Inquire | Inquire | Inquire | Inquire |
| Sample Volume | 10 ml | Typically 900 mL water and 50 mL cyclohexane (min. 10 mL solvent required per measurement) | 5 ml at 10 ml/min, 12.5 ml at 25 ml/min | Inquire | Inquire |
| Get Quote | | | | | |