Spectrophotometers are used to measure the concentration of a known substance in a solution. They do this by passing a light through the substance and measuring light intensity as a function of wavelength. Either single beam or double beam spectrophotometers can be purchased. In a single beam spectrophotometer, a reference standard is used to measure light intensity before and after the sample is loaded. For double beam spectrophotometers the beam is split with one beam passing through the standard and the other through the sample to compare intensities. While single beam spectrophotometers are typically less expensive and have higher sensitivity, double beam spectrophotometers tend to be more stable and easier to use. Spectrophotometers are important pieces of equipment in chemistry, physics, biochemistry, clinical, and materials testing labs.
Find, compare, and request a quote for spectrophotometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |  |  |
| Company | Thermo Fisher Scientific | Thermo Fisher Scientific | Thermo Fisher Scientific | Thermo Fisher Scientific | Thermo Fisher Scientific |
| Item | BioMate 160 UV-Vis Spectrophotometer | GENESYS™ 140 Vis Spectrophotometer | GENESYS™ 50 UV-Vis Spectrophotometer | NanoDrop™ Eight Spectrophotometer | Nicolet™ Summit™ X FTIR Spectrometer |
| Citations | | | | | |
| Catalog Number | 840-301000 | 840-308000 | 840-298000 | NDE-GL / NDEIGHT-LAPTOP / NDEIGHT-E1PIP / NDEIGHT-PIP | IQLAADGAAGFAQXMBNM |
| Price | | | | | |
| Type | UV-Visible | Visible | UV-Visible | UV VIS Spectrophotometer | Inquire |
| Wavelength Range | 190 nm to 1100 nm | 325 nm to 1100 nm | 190 nm to 1100 nm | 190 to 850 nm | 8000 to 350 cm-1 |
| Wavelength Accuracy | ± 0.5 nm | ± 0.5 nm | ±0.5 nm | ± 1 nm | Inquire |
| Scanning Speed | Slow, medium and fast - up to 1600 nm/min | Automatic – up to 1800 nm/min | Slow, medium and fast - up to 1600 nm/min | 8 samples in < 20 sec | Inquire |
| Spectral Bandwidth | 2 nm | 5 nm | 2 nm | < 1.8 nm | Inquire |
| Optical System | Dual Beam | Dual Beam | Dual Beam | 2048-element CMOS linear image sensor | Inquire |
| Light Source | Xenon Flash Lamp >5 years typical, 3 years guaranteed) | Tungsten-Halogen (>1000 hours) | Xenon Flash Lamp (>5 years typical, 3 years guaranteed) | Xenon flash lamp | Inquire |
| Resolution | Inquire | Inquire | Inquire | ≤ 1.8 nm (FWHM at Hg 254 nm) | Better than 0.6 cm-1 |
| Description | Perform quantitative measurements in life science laboratories with the automated and network-ready Thermo Scientific™ BioMate™ 160 UV-Visible Spectrophotometer. The BioMate 160 Spectrophotometer offers pre-programmed assay methods for nucleic acid and protein concentration as well as cell culture Perform quantitative measurements in life science laboratories with the automated and network-ready Thermo Scientific™ BioMate™ 160 UV-Visible Spectrophotometer. The BioMate 160 Spectrophotometer offers pre-programmed assay methods for nucleic acid and protein concentration as well as cell culture measurements. Optimized for usability and performance, this platform features a high-resolution color touchscreen, Wi-Fi networking, and a rugged design.... Read More | Perform quantitative measurements in routine industrial QA/QC or university chemistry labs with the automated and network-ready Thermo Scientific™ GENESYS 140 Vis Spectrophotometers. Optimized for usability and performance, this platform features a high-resolution color touchscreen, Wi-Fi Perform quantitative measurements in routine industrial QA/QC or university chemistry labs with the automated and network-ready Thermo Scientific™ GENESYS 140 Vis Spectrophotometers. Optimized for usability and performance, this platform features a high-resolution color touchscreen, Wi-Fi networking, and a rugged design built for repetitive, heavy use environments. Regarded worldwide for reliability, accuracy and reproducibility, GENESYS spectrophotometers meet today’s expectations for advanced technology in a compact, robust package.... Read More | Perform routine measurements for quality control or teaching in the chemistry classroom with the rugged Thermo Scientific™ GENESYS™ 50 UV-Visible Spectrophotometer. Offered in a single cell configuration, this instrument is designed with a sloping surface to shed spills and a washable sampling Perform routine measurements for quality control or teaching in the chemistry classroom with the rugged Thermo Scientific™ GENESYS™ 50 UV-Visible Spectrophotometer. Offered in a single cell configuration, this instrument is designed with a sloping surface to shed spills and a washable sampling compartment for easy clean up. A 7-inch touchscreen interface, local control software (no PC needed) and Wi-Fi-ready networking make the GENESYS 50 UV-Vis Spectrophotometer the ideal choice for daily sampling purposes.... Read More | Increase the chances of success in your analyses with efficient analysis of your sample quantity and quality using the Thermo Scientific™ NanoDrop™ Eight UV-Vis spectrophotometer. Ideal for pharma/biotech and academic researchers measuring larger number of nucleic acid and protein samples. NanoDrop Increase the chances of success in your analyses with efficient analysis of your sample quantity and quality using the Thermo Scientific™ NanoDrop™ Eight UV-Vis spectrophotometer. Ideal for pharma/biotech and academic researchers measuring larger number of nucleic acid and protein samples. NanoDrop Eight measures 8 samples at a time in less than 20 seconds. Software identifies sample contaminants and reports true sample concentration with the built-in Thermo Scientific™ Acclaro™ Sample Intelligence technology. Optional software allows you to more easily comply with 21 CFR Part 11 regulation.... Read More | Inquire |
| Quantity | EA | EA | EA | EA | Inquire |