Spectrophotometers are used to measure the concentration of a known substance in a solution. They do this by passing a light through the substance and measuring light intensity as a function of wavelength. Either single beam or double beam spectrophotometers can be purchased. In a single beam spectrophotometer, a reference standard is used to measure light intensity before and after the sample is loaded. For double beam spectrophotometers the beam is split with one beam passing through the standard and the other through the sample to compare intensities. While single beam spectrophotometers are typically less expensive and have higher sensitivity, double beam spectrophotometers tend to be more stable and easier to use. Spectrophotometers are important pieces of equipment in chemistry, physics, biochemistry, clinical, and materials testing labs.
Find, compare, and request a quote for spectrophotometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
| | |
Company | JASCO | JASCO |
Item | V-750 UV-Visible Spectrophotometer | CPL-300 Circularly Polarized Luminescence Spectrophotometer |
Citations | | |
Figures | | |
Catalog Number | V-750 | CPL-300 |
Price | | |
Type | UV-Visible | Circularly Polarized Luminescence |
Wavelength Range | 190 to 900 nm | 250 to 850 nm (Optional: 400 to 1,100 nm with PMT detector) |
Wavelength Accuracy | ±0.2 nm (at 656.1 nm) | Inquire |
Scanning Speed | 10 to 4,000 nm/min (8,000 nm/min in preview mode) | up to 10,000 nm/min |
Spectral Bandwidth | 0.1, 0.2, 0.5, 1, 2, 5, 10 nm L2, L5, L10 nm (low stray light mode) M1, M2 nm (micro cell mode) | Inquire |
Optical System | Czerny-Turner mount Double monochromator Fully symmetrical double beam type | Double prism monochromators for both excitation and emission optics / Piezoelastic modulator / Lock-in amplifier |
Light Source | Halogen lamp, Deuterium lamp | 150W Ozone-free air-cooled Xe lamp (Option: 150W air-cooled HgXe lamp) |
Resolution | =BS9 | Wavelength Resolution: 0.025 nm CPL Resolution: 0.00001 mdeg |
Description | The V-750 UV-Visible Spectrophotometer optical design uses precision double-beam optics with variable spectral bandwidth. A high sensitivity PMT detector provides accurate and reproducible measurements for low to high concentration samples. By controlling the high voltage applied to the PMT, the The V-750 UV-Visible Spectrophotometer optical design uses precision double-beam optics with variable spectral bandwidth. A high sensitivity PMT detector provides accurate and reproducible measurements for low to high concentration samples. By controlling the high voltage applied to the PMT, the dynode feedback offers a wider dynamic range than is generally found on uv-visible spectrophotometers. For high resolution measurements, such as gas and vapor phase spectroscopy, the spectral bandwidth can be set as narrow as 0.1 nm. Special low stray light slit settings which optimize the light image on the monochromator provide increased linearity to up to 5 absorbance units.... Read More | The CPL-300 Circularly Polarized Luminescence Spectrophotometer supplements the information obtained from other chiroptical techniques such as electronic or vibrational circular dichroism. Circular dichroism (CD) spectroscopy is widely used in the study of optically active substances. CD The CPL-300 Circularly Polarized Luminescence Spectrophotometer supplements the information obtained from other chiroptical techniques such as electronic or vibrational circular dichroism. Circular dichroism (CD) spectroscopy is widely used in the study of optically active substances. CD spectroscopy provides information about the structure of optically active substances in the electronic ground state, however, CPL spectroscopy provides information about excited states. The two techniques are therefore complimentary. The CPL-300 uses the original 180° fluorescence collection approach proposed by Steinberg. The standard ozone-free 150W Xe lamp can be user-replaced with an Hg/Xe source. The instrument’s unique double-prism excitation and emission monochromators offer very low stray-light and no spurious linear polarization effects caused by instruments that use diffraction gratings. These are both extremely important as CPL signals tend to be very weak.... Read More |
Quantity | EA | EA |