X-ray diffraction (XRD) allows one to ascertain the molecular structure of a crystalline material by diffracting X-rays through the sample. An XRD analyzer obtains interference patterns reflecting lattice structures by varying the angle of incidence of the X-ray beam. Thus, the precision, speed of rotation, and beam size of the X-rays become important parameters by which to judge products. Benchtop XRD can be targeted for single crystal diffraction for imaging lattices; powder diffraction for phase determination; identifying unfamiliar substances for use in inspection, crystallography, and pharmaceutical research correlating crystal structures with drug efficacy. X-ray generators can reach 18 KW in power and detectors typically come as compound silicon arrays, Peltier-Cooled, Silicon Drift, or Scintillation Counter variants. Software targeted for specific XRD applications is available for upgrade in some analyzer models.
Find, compare, and request a quote for X-ray diffractometers (XRD instruments) across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |  |
| Company | Rigaku Corporation | Rigaku Corporation | Rigaku Corporation | Rigaku Corporation |
| Item | SmartLab SE X-ray Diffractometer | DicifferX WAXS Edition High-speed wide-angle X-ray Scattering System | Rigaku XtaLAB Synergy Flow Automated Single Crystal XRD | XtaLAB Synergy-Custom |
| Citations | | | | |
| Catalog Number | SmartLab SE | DicifferX WAXS | | XtaLAB Synergy-Custom |
| Price | | | | |
| X-Ray Tube | 3 kW sealed X-ray tube | 1.2 kW micro source rotating anode X-ray generator | Inquire | Inquire |
| X-Ray Generator | Inquire | Inquire | Inquire | MicroMax-007 HF microfocus rotating anode source or the highest-flux in-house X-ray source, the FR-X (Mo, Cu, or Cr). |
| Goniometer Type | Inquire | WAXS camera | Intelligent Goniometer Head (IGH) with motorized automation; automated sample centering in as little as 6 seconds | Fast kappa geometry goniometer |
| Detector(s) | HyPix-400 2D, D/teX Ultra 250 1D | High-energy resolution 2D hybrid pixel array detector (HyPix) | Direct X-ray detection detectors (varies by Synergy base model selected) | HyPix-6000HE, the large theta coverage HyPix-Arc 150° or the Dectris EIGER 4M. |
| Description | The SmartLab SE is a highly versatile multipurpose X-ray diffractometer with built-in intelligent guidance. It offers continued refinement of the original ease of use features that enabled the original SmartLab to receive the R&D 100 Award in 2006: automatic alignment, component recognition, cross The SmartLab SE is a highly versatile multipurpose X-ray diffractometer with built-in intelligent guidance. It offers continued refinement of the original ease of use features that enabled the original SmartLab to receive the R&D 100 Award in 2006: automatic alignment, component recognition, cross beam optics and advanced photon counting hybrid pixel array detectors (HPAD).
Features: - SmartLab Studio II software based on a new architecturally integrated modular platform
- Cross-beam optics module switches between Bragg-Brentano and parallel beam without the need to change optics.
- HyPix-400 2D detector enables seamless switch between 0D, 1D and 2D detection mode depending on application type.
- D/teX Ultra 250 1D detector accelerates powder diffraction by a factor of 250 in speed and provides adjustable energy resolution of approximately 20% or 4% depending on
sample type. - Integrated intelligent Guidance software enables fully automated measurement including optics and sample alignment.
- Self-aligned optics maximize instrument uptime and minimize cost of ownership.
... Read More | Breakthrough speed and versatility for polymer structure analysis
- Next-generation WAXS system equipped with a high-brilliance X-ray source
- Structural information captured non-destructively in just a few seconds of exposure
- Time-resolved in-situ measurements for heating, stretching, and
Breakthrough speed and versatility for polymer structure analysis
- Next-generation WAXS system equipped with a high-brilliance X-ray source
- Structural information captured non-destructively in just a few seconds of exposure
- Time-resolved in-situ measurements for heating, stretching, and humidity conditions
DicifferX WAXS Edition redefines what’s possible for in-house WAXS measurements.
By delivering structural insights in seconds, it accelerates decision-making and drives rapid innovation.
Studies once requiring long measurement times or external facilities can now be performed directly in your
own laboratory, streamlining workflows and empowering faster materials development.... Read More | Inquire | Customized Single Crystal Diffraction System With Microfocus Rotating Anode Generator
Features: - Ultimate flexibility with customized X-ray system specifically tailored to the needs of your research. Dual ports allow for various combinations of crystallography and SAXS configurations. Your choice
Customized Single Crystal Diffraction System With Microfocus Rotating Anode Generator
Features: - Ultimate flexibility with customized X-ray system specifically tailored to the needs of your research. Dual ports allow for various combinations of crystallography and SAXS configurations. Your choice of VariMax™ confocal double-bounce optics for better spectral purity and beam size to match your sample types.
- Faster, accurate data collection due to high-speed kappa goniometer, high-flux rotating anode X-ray source, fast, low-noise X-ray detector, and highly optimized instrument control software.
- Improve your ability to investigate small samples due to the increased flux from the rotating anode X-ray source as well as the extreme low noise of the HyPix X-ray detectors. Noise-free images mean you can count longer for weakly diffracting crystals without a loss in data quality arising from detector noise.
- Screen crystals in situ with optional XtalCheck crystallization plate screening device.
- Enhance your ability to resolve large unit cells, twins or incommensurate lattices when you select the optional motorized variable beam slit in order to alter divergence to adapt the source to your sample’s requirements.
... Read More |
| Get Quote | | | | |