X-ray diffraction (XRD) allows one to ascertain the molecular structure of a crystalline material by diffracting X-rays through the sample. An XRD analyzer obtains interference patterns reflecting lattice structures by varying the angle of incidence of the X-ray beam. Thus, the precision, speed of rotation, and beam size of the X-rays become important parameters by which to judge products. Benchtop XRD can be targeted for single crystal diffraction for imaging lattices; powder diffraction for phase determination; identifying unfamiliar substances for use in inspection, crystallography, and pharmaceutical research correlating crystal structures with drug efficacy. X-ray generators can reach 18 KW in power and detectors typically come as compound silicon arrays, Peltier-Cooled, Silicon Drift, or Scintillation Counter variants. Software targeted for specific XRD applications is available for upgrade in some analyzer models.
Find, compare, and request a quote for X-ray diffractometers (XRD instruments) across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |  |  |
| Company | Rigaku Corporation | Rigaku Corporation | Rigaku Corporation | Rigaku Corporation | Rigaku Corporation |
| Item | DicifferX WAXS Edition | MiniFlex Benchtop X-ray Diffractometer | Rigaku XtaLAB Synergy Flow Automated Single Crystal XRD | SmartLab High-Resolution Diffraction System | SmartLab SE X-ray Diffractometer |
| Citations | | | | | |
| Catalog Number | | MiniFlex | | SmartLab | SmartLab SE |
| Price | | | | | |
| X-Ray Tube | Inquire | Inquire | Inquire | 3 kW sealed X-ray tube | 3 kW sealed X-ray tube |
| X-Ray Generator | High-brilliance rotating anode with multilayer focusing mirror (10^9 cps at 200 µm beam) | Cu, Co, Fe, or Cr, 40 kV, 15 mA | Inquire | 9.0 kW Rotating Anode Generator | Inquire |
| Goniometer Type | No goniometer (open stage design) | Vertical, Theta or 2Theta | Intelligent Goniometer Head (IGH) with motorized automation; automated sample centering in as little as 6 seconds | High Resolution Theta/Theta Closed Loop | Inquire |
| Detector(s) | HyPix-6000 2D HPAD on motorized 2-axis stage | D/teX, Ultra 1D High speed silicon strip detector | Direct X-ray detection detectors (varies by Synergy base model selected) | D/teX Ultra 250 silicon strip detector | HyPix-400 2D, D/teX Ultra 250 1D |
| Description | Inquire | New sixth generation MiniFlex X-ray diffractometer (XRD) is a multipurpose analytical instrument that can determine: phase identification and quantification, percent (%) crystallinity, crystallite size and strain, lattice parameter refinement, Rietveld refinement, and molecular structure. It is New sixth generation MiniFlex X-ray diffractometer (XRD) is a multipurpose analytical instrument that can determine: phase identification and quantification, percent (%) crystallinity, crystallite size and strain, lattice parameter refinement, Rietveld refinement, and molecular structure. It is widely used in research, especially in material science and chemistry, as well as in industry for research and quality control. It is the newest addition to MiniFlex series of benchtop X-ray diffraction analyzers from Rigaku, which began with the introduction of the original MiniFlex system decades ago.
Overview: - New 6th generation design
- Compact, fail-safe radiation enclosure
- Incident beam variable slit
- Simple installation and user training
- Factory aligned goniometer system
- Laptop computer operation
Measurements: - Phase identification
- Phase quantification
- Percent (%) crystallinity
- Crystallite size and strain
- Lattice parameter refinement
- Rietveld refinement
- Molecular structure
Options: - 8-position autosampler
- Graphite monochromator
- D/teX Ultra: silicon strip detector
- HyPix-400 MF: 2D HPAD detector
- Air sensitive sample holder
- Travel case
... Read More | Inquire | The SmartLab high-resolution diffraction system represents the state of the art in fully automated modular XRD systems. The system incorporates a high resolution theta/theta closed loop goniometer drive system, CBO, an in-plane scattering arm, an optional 9.0 kW rotating anode generator, and a fullyThe SmartLab high-resolution diffraction system represents the state of the art in fully automated modular XRD systems. The system incorporates a high resolution theta/theta closed loop goniometer drive system, CBO, an in-plane scattering arm, an optional 9.0 kW rotating anode generator, and a fully automated optical system to make advanced measurements possible for both expert and novice users of the system.
Winner of the 2006 R&D 100 Award for technical innovation, the SmartLab is design for completely automated analysis of thin films and other advanced materials. Powered by Guidance, Rigaku's revolutionary knowledge based software package, SmartLab uses fully deveopled measurement packages for completely automated measurement of thin films, nanomaterials, powders, and liquids. Measurement packages exist for powder diffraction, glancing incidence diffraction, in-plane diffraction, X-ray reflectivity, and small angle X-ray scattering (SAXS) measurements.
Features - Θ/Θ design for horizontal sample mounting
- Closed loop drive system for high resolution scanning
- Optional 9.0 kW rotating anode generator
- Fully automatic system alignment
- Guidance software based automated measurement
- 300 mm wafer handling
- CBO for focusing and parallel beam geometries without reconfiguration
- In-plane diffraction arm for in-plane measurements without reconfiguration
- High resolution optics
- SAXS capabilities
... Read More | The SmartLab SE is a highly versatile multipurpose X-ray diffractometer with built-in intelligent guidance. It offers continued refinement of the original ease of use features that enabled the original SmartLab to receive the R&D 100 Award in 2006: automatic alignment, component recognition, cross The SmartLab SE is a highly versatile multipurpose X-ray diffractometer with built-in intelligent guidance. It offers continued refinement of the original ease of use features that enabled the original SmartLab to receive the R&D 100 Award in 2006: automatic alignment, component recognition, cross beam optics and advanced photon counting hybrid pixel array detectors (HPAD).
Features: - SmartLab Studio II software based on a new architecturally integrated modular platform
- Cross-beam optics module switches between Bragg-Brentano and parallel beam without the need to change optics.
- HyPix-400 2D detector enables seamless switch between 0D, 1D and 2D detection mode depending on application type.
- D/teX Ultra 250 1D detector accelerates powder diffraction by a factor of 250 in speed and provides adjustable energy resolution of approximately 20% or 4% depending on
sample type. - Integrated intelligent Guidance software enables fully automated measurement including optics and sample alignment.
- Self-aligned optics maximize instrument uptime and minimize cost of ownership.
... Read More |
| Get Quote | | | | | |