Description | DTC 300 is a guarded heat flow meter measuring the thermal conductivity over a wide range of temperatures accordingly to the ASTM E1530 Standard. It employs one calorimeter module, located in the bottom stack, for the measurement of thermal conductivity, and a side guard furnace to prevent edge heatDTC 300 is a guarded heat flow meter measuring the thermal conductivity over a wide range of temperatures accordingly to the ASTM E1530 Standard. It employs one calorimeter module, located in the bottom stack, for the measurement of thermal conductivity, and a side guard furnace to prevent edge heat loss. The contact resistance is minimized by applying a pneumatic load to the test stack, and by using a thermally conductive interface compound.... Read More | The Discovery Laser Flash DLF 2800 is an advanced freestanding instrument for the measurement of thermal diffusivity and specific heat capacity of materials from room temperature to 2800°C. The distinctive design incorporates a proprietary laser, laser optics, detector, and furnace technologies, andThe Discovery Laser Flash DLF 2800 is an advanced freestanding instrument for the measurement of thermal diffusivity and specific heat capacity of materials from room temperature to 2800°C. The distinctive design incorporates a proprietary laser, laser optics, detector, and furnace technologies, and along with the unique six-position sample carousel, ensures unprecedented measurement accuracy and sample throughput.
DLF 2800 Features:
- Powerful laser provides 40% more energy than any competitive design for the most accurate testing to the highest temperatures and widest range of samples, regardless of thickness and thermal conductivity
- Proprietary fiber optic wand delivers 99% homogeneous beam at the sample for increased measurement accuracy
- Unique six-position carousel for unmatched throughput and accurate heat capacity measurements
- Flexible carousel design configurable with a variety of sample holders, adapters and special fixtures over the widest testing range
- Advanced furnace for uncompromised temperature performance from RT to 2800°C, and measurements in inert gas or vacuum
- High sensitivity IR detector for optimum signal-to-noise ratio, delivering the highest accuracy over the entire temperature range
- Real-time pulse mapping for unmatched accuracy of thermal diffusivity measurements for testing of thin and highly conductive materials
- Meets a variety of industry standard test methods including: ASTM E1461, ASTM C714, ASTM E2585, ISO 13826, ISO 22007-Part4, ISO 18755, BS ENV 1159-2, DIN 30905
*US Patent #6.375.349.81... Read More | The Discovery Xenon Flash 200+ features a patented High Speed Xenon-Pulse Delivery™ source (HSXD) and a multi-faceted Light Pipe™. Together these optics deliver a light pulse of unsurpassed power and uniform intensity to the specimen while preventing sample holder overflash. Only TA The Discovery Xenon Flash 200+ features a patented High Speed Xenon-Pulse Delivery™ source (HSXD) and a multi-faceted Light Pipe™. Together these optics deliver a light pulse of unsurpassed power and uniform intensity to the specimen while preventing sample holder overflash. Only TA Instruments high energy Xenon design is capable of testing samples to a diameter of 25.4 mm over a temperature range from -175 °C to 900 °C. The use of large samples diminishes errors associated with inhomogeneity and permits representative measurements of poorly dispersed composites. The DXF platform is designed for research and development programs as well as production control.
DXF 200+ Features
- Sub-ambient temperature system with highly efficient liquid nitrogen cooling system and solid state PIN detectors for accurate and stable temperature control to an industry leading -175°C.
- Easily swappable autosampler trays can accommodate up to twelve samples 12.7 mm diameter or six 25.4 mm diameter samples, plus many more sizes and shapes.
- Software controlled PIN loading can be adjusted to maintain perfect contact regardless of sample thickness.
- Patented High Speed Xenon-Pulse-Delivery system provides 50% more energy than competitive designs for the highest degree of accuracy on widest range of samples regardless of thickness or thermal conductivity.
- Wide variety of sample trays accommodates multiple sample sizes (up to 25.4 mm), shapes, and special fixtures (liquids, powders, laminates, films, etc.) for maximum sample testing flexibility.
- Patented Light Pipe™ for the most effective collection and collimation of light and homogeneous delivery of radiation to the sample.
- Can test samples with maximum diameter of 25.4 mm diameter for easier sample preparation and handling, as well as improved results for inhomogeneous materials.
- Real-time pulse mapping for superior thermal diffusivity of thin and highly conductive materials.
- Designed to meet industry standard test methods including: ASTM E1461, ASTM C714, ASTM E2585, ISO 13826, ISO 22007-Part4, ISO 18755, BS ENV 1159-2, DIN 30905, and DIN EN821
... Read More | The FOX 200 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity according to ASTM C518 and ISO 8301. Operating in standalone or PC-controlled configurations, the FOX Heat Flow Meter provides rapid, accurate results. The instrument features proprietary thin film The FOX 200 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity according to ASTM C518 and ISO 8301. Operating in standalone or PC-controlled configurations, the FOX Heat Flow Meter provides rapid, accurate results. The instrument features proprietary thin film heat flux transducers, digital thickness measurements and responsive temperature control. The FOX 200 is a versatile instrument and is especially well-suited to measuring slices of cellular plastics.... Read More | The FOX 50 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity and provides rapid results in a compact footprint. The instrument is configured with the identical high performance features and proprietary technologies of the larger FOX systems including thin filmThe FOX 50 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity and provides rapid results in a compact footprint. The instrument is configured with the identical high performance features and proprietary technologies of the larger FOX systems including thin film heat flux transducers, digital thickness measurements, responsive temperature control, plus an integrated contact-resistance correction.... Read More |