HPLC Detector

An HPLC detector is used to analyze the components of the eluted mixture that is collected after being run through an HPLC column. Differences in detector type are based on what is being detected. Detection can be done by measuring absorbance, changes in reflex indices, molecular weight, and fluorescence among others. When selecting a detector, it is important to consider the sample type being analyzed. Some sample types will not work or will have lower sensitivity on particular detectors. Also of consideration is the type of information that is being sought by the analysis and what method will be used when running the column, for example, some detectors will work with the gradient method while others will not.

Find, compare, and request a quote for HPLC detectors across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyWaters | Wyatt TechnologyWaters | Wyatt TechnologyWaters | Wyatt TechnologyWaters | Wyatt TechnologyWaters | Wyatt Technology
ItemmicroDAWN™ Multi-Angle Light Scattering Instrument for UHP-SEC-MALSmicroOptilab™ Refractive Index Detector for UHPLCminiDAWN™ Multi-Angle Light Scattering (MALS) Detector for SEC-MALSOptilab™ Refractive Index Detector for HPLC/GPCWyattQELS™ Light Scattering Detector Module
Citations
(1)
(1)
Catalog NumbermicroDAWNmicroOptilabminiDAWNOptilabWyattQELS
Price
TypeMALS and optional DLSRefractive Index DetectorMALS and optional DLSRefractive Index DetectorDynamic Light Scattering
Detector(s)High-gain, high dynamic range, static light scattering detectors at 3 anglesDifferential Refractive Index (dRI)High-gain, high-dynamic range photodiodes at 3 detection angles for MALS. Optional avalanche photodiode for simultaneous dynamic light scattering measurements.Differential Refractive Index (dRI)Avalanche photodiode coupled to a multimode optical fiber
ApplicationsWith SEC/GPC: determination of distributions of absolute molar mass, size, conformation, conjugate ratio.Measure concentrations of all types of samples in almost all solventsWith SEC/GPC: determination of distributions of absolute molar mass, size, conformation, conjugate ratio. With Calypso CG-MALS: characterization of biomolecular interactions.GPC/SEC analysis of macromolecules by SEC-MALSHigh-resolution size distributions with fractionation by SEC or FFF; conformation when combined with MALS molar mass and/or size data
DescriptionThe microDAWN™ MALS detector performs absolute characterization of macromolecules eluting from UHPLC (or UPLC), determining molar mass and size independently of retention time and molecular reference standards. This instrument offers superb sensitivity over a wide range of molar mass, size and... Read MoreThe microOptilab™ brings universal detection capabilities, unsurpassed concentration range, and superb sensitivity and linearity to the domain of UHPLC. Key benefits include low band broadening, < 4 µL, to maintain the resolution of very narrow UHPLC peaks. Its dRI measurement range is, - 4... Read MoreCouple the miniDAWN™ to your favorite HPLC or FPLC to determine the absolute molar masses and sizes of macromolecules and nanoparticles in solution from hundreds to millions of Daltons—without the need for column calibration standards. This sensitive unit requires as little as 25 ng injected ... Read MoreThe Optilab™ is a unique dRI detector for standard HPLC/GPC with 256 times the detection power and 50 times the dynamic range over alternative RI detectors for chromatography. This detector measures the solvent's absolute refractive index, a requirement for MALS calculations, at the same ... Read MoreThe WyattQELS™ dynamic light scattering (DLS) module integrates into a DAWN™, miniDAWN™ or microDAWN™ online multi-angle light scattering (MALS) instrument in order to determine high-resolution particle size distributions, when used in conjunction with a separation technique ... Read More
Wavelength RangeInquireInquireInquireInquireInquire
Get Quote