Assay Kits

Assay kits are used to carry out analyses in a broad scope of applications including the study of targets such as drugs, molecules, disease pathways, chemical elements or compounds, and organisms. They are a routine procedure in the modern pharmaceutical, medical and forensic world as well as research and university laboratories around the globe. Assay kits come with all the necessary reagents, instructions and protocols for fast and efficient processing, allowing for repeatable results.
CompanyIBL-AmericaIBL-AmericaIBL-AmericaIBL-AmericaIBL-America
ItemACTH IRMA AssayANGPTL8 ELISAClostridium tetani toxin IgG ELISAFree T3 RIAGlutamate ELISA Assay
Citations
(1)
(1)
Catalog NumberKIR006127795IB79888KIRB1579IB89151R
PriceSupplier PageSupplier PageSupplier PageSupplier PageSupplier Page
DescriptionImmunoradiometric assay (RIA) kit for the determination of human Adrenocorticotropic Hormone (ACTH) in EDTA plasma. For research use only, not for use in diagnsotic procedures.Solid phase sandwich ELISA for the determination of Human ANGPTL8 ELISA in serum, EDTA plasma and cell culture supernatant. For research use only, not for use in diagnostic procedureThe Clostridium tetani toxin IgG ELISA is intended for the determination of IgG class antibodies against Clostridium tetani toxin in human serum or plasma (citrate, heparin). For research use only - not for use in diagnostic procedures.Radioimmunoassay (RIA) for the determination of human-free triiodothyronine (T3) in serum or EDTA plasma. For research use only, not for use in diagnostic procedures.Enzyme Immunoassay (ELISA) for the determination of L-Glutamate in urine and various biological samples. For research use only, not for use in diagnostic procedures.
Detection TargetLHNSESoluble Prorenin ReceptorFree Triiodothyronine (T3)FSH
Sample TypeSerumSerumSerum, Blood Plasma, Urine, Cell Culture SupernatantSerum, Blood PlasmaSerum
MethodRadio Immuno Assay (RIA)Enzyme-Linked Immunosorbent Assay (ELISA)Enzyme-Linked Immunosorbent Assay (ELISA)Radio Immuno Assay (RIA)Enzyme-Linked Immunosorbent Assay (ELISA)
Detection Range9.6 to 1932 pg/mL0 / 0.61 - 80 pmol/L0 to 1.0 IU/mL0 / 2.10 to 44.0 pmol/L0.6 to 60 µg/mL
SensitivityInquireInquire24 pg/mL98.25% (95% confidence interval: 93.81% - 99.79%)Inquire
Assay Time3 hrs (incubation)2 hours total incubation time.1 hr 45 mins (incubation)2 hours total incubation time.5 hrs 20 mins (incubation)
Get QuoteSupplier PageSupplier PageSupplier PageSupplier PageSupplier Page

Articles