Description | The Agilent BioTek Synergy HTX is a compact, economical multimode reader for 6- to 384-well microplates and Take3 microvolume plates. The unique dual optics design provides superior performance for UV-Vis absorbance, fluorescence, luminescence, and AlphaScreen/AlphaLISA workflows. With incubation The Agilent BioTek Synergy HTX is a compact, economical multimode reader for 6- to 384-well microplates and Take3 microvolume plates. The unique dual optics design provides superior performance for UV-Vis absorbance, fluorescence, luminescence, and AlphaScreen/AlphaLISA workflows. With incubation and shaking, plus a dual reagent injector module, the system will meet all your assay requirements now and in the future. Synergy HTX is controlled by the easy-to-use, yet powerful, Gen5 software for data collection, analysis, exporting, and reporting.... Read More | The Agilent BioTek Cytation 1 cell imaging multimode reader combines fluorescence and high contrast brightfield imaging with conventional multimode detection. This affordable imaging reader delivers performance and economy compared to other digital microscopy systems. The BioTek Cytation 1 design The Agilent BioTek Cytation 1 cell imaging multimode reader combines fluorescence and high contrast brightfield imaging with conventional multimode detection. This affordable imaging reader delivers performance and economy compared to other digital microscopy systems. The BioTek Cytation 1 design provides both quantitative phenotypic cellular data with well-based quantitative data. The multimode detection module has high sensitivity filter-based fluorescence and a monochromator for UV-Vis absorbance. Temperature control and shaking are standard. CO2/O2 control and reagent injectors are available. Gen5 software simplifies image capture and plate reading.... Read More | The Agilent BioTek Epoch 2 microplate spectrophotometer delivers excellent performance for UV-Vis absorbance measurements. Measurements can be performed in 6- to 384-well microplates, cuvettes, and in microvolume samples with the available Take3 microvolume plate. The broad wavelength range enables The Agilent BioTek Epoch 2 microplate spectrophotometer delivers excellent performance for UV-Vis absorbance measurements. Measurements can be performed in 6- to 384-well microplates, cuvettes, and in microvolume samples with the available Take3 microvolume plate. The broad wavelength range enables applications from nucleic acid and protein quantification in the low UV to microbial growth assays higher wavelengths.;Epoch 2 is easy to use and the optional touch screen interface makes it simple to choose predefined protocols or to define custom programs. Endpoint, kinetic, spectral scanning and well area scanning modes, plus incubation and shaking enable wide-ranging applications.... Read More | The Agilent BioTek Synergy LX multimode reader automates many common microplate assays. The high-quality optic design ensures excellent data in absorbance, fluorescence, and luminescence detection modes. This affordable system is ideal for many common assays including nucleic acid and protein The Agilent BioTek Synergy LX multimode reader automates many common microplate assays. The high-quality optic design ensures excellent data in absorbance, fluorescence, and luminescence detection modes. This affordable system is ideal for many common assays including nucleic acid and protein quantification, ELISA, BCA, Bradford, and cell viability. The data display, output to a USB flash drive, printer, or Gen5 software make Synergy LX a versatile assay workstation. The large touch screen user interface and onboard software simplify programming and save time in operation of microplate and microvolume assays.... Read More | The Cytation C10 confocal imaging reader combines automated confocal and widefield microscopy with conventional multimode microplate reading in a unique, proprietary design. The automated water- immersion objectives capture more light, driving lower exposure times and reducing phototoxic impacts on The Cytation C10 confocal imaging reader combines automated confocal and widefield microscopy with conventional multimode microplate reading in a unique, proprietary design. The automated water- immersion objectives capture more light, driving lower exposure times and reducing phototoxic impacts on live cells. The spinning-disk confocal module and accompanying disk pinhole options allow a researcher to look deeper into thick sample biology with improved clarity and detail. High-quality components used in the system, including a Hamamatsu scientific CMOS (sCMOS) camera, Olympus objectives and laser-based illumination enable excellent image quality, at a significantly lower price than others.
Cytation C10 also includes widefield fluorescence, brightfield and phase contrast optics. Onboard environmental controls enable live cell assays. Multiplate live cell assays are accomplished with Cytation C10 integrated with the Agilent BioTek BioSpa 8 automated incubator. Cytation C10 brings high-performance, affordable confocal to every laboratory.... Read More |
Reading Modes | Fluorescence, Time-Resolved Fluorescence, Luminescence, UV-Visible Absorbance | Endpoint, kinetic, spectral scanning, well area scanning | UV-Visible Absorbance | UV-Vis absorbance, Fluorescence intensity, Luminescence | Fluorescence, phase contrast, color brightfield, user-selectable brightfield/high contrast brightfield |