Description | Automated pipetting ensures consistent performance over multiple assay conditions on a microplate.
The FlexStation® 3 Multi-Mode Microplate Reader measures absorbance, fluorescence intensity, fluorescence polarization, luminescence, and time-resolved fluorescence. Programmable liquid handling Automated pipetting ensures consistent performance over multiple assay conditions on a microplate.
The FlexStation® 3 Multi-Mode Microplate Reader measures absorbance, fluorescence intensity, fluorescence polarization, luminescence, and time-resolved fluorescence. Programmable liquid handling allows for perfectly timed, automated biochemical and cell-based assays. The reader adds up to three transfers of assay reagents from a 96- or 384-well source plate to enhance assay design using integrated fluidics.
Onboard pipettor -
Integrated 8-channel or 16-channel pipettor increases assay flexibility by transferring reagents from 96 or 384 distinct wells in a source plate to the read plate.
Optimal assay excitation -
Dual monochromators allow users to target the optimal assay excitation and emission wavelengths and eliminate the need to change expensive band pass filters between experiments.
Low volume applications -
SpectraDrop™ Micro-Volume Microplate offers a high-throughput solution for low volume measurement, accelerating sample preparation time and increased productivity in DNA, RNA and protein research.
Robot integration -
The FlexStation 3 reader can be integrated with all leading partner robots and with our out-of-the-box automation solution for savings on up-front integration time and resources.
Other features and benefits include: -
- Enable more assay conditions
-
Automate pipetting
-
Validate your reader
... Read More | Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes.
With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user-configurable detection modules, the reader provides you with the ability to explore cellular pathways and protein expression on one microplate reader.
User-configurable applications -
User-configurable detection modules expand the reader’s detection capabilities to include AlphaScreen, Time-Resolved Fluorescence, HTRF, fast kinetics with injectors, western blot detection, and more.
No-stain cell analysis -
The StainFree™ Cell Detection Algorithm for brightfield cell segmentation enables cell counting and confluency measurement without destructive stains, simplifying the cell counting workflow.
Multi-channel functionality -
Two fluorescence detection channels on the MiniMax cytometer enable the analysis of cell viability or cell toxicity assays, including ratiometric assays like live-dead and transfection efficiency.
Cellular pathway analysis -
Cell confluence and cell viability imaging, western blot analysis, and quantitation of nucleic acids and protein, can be captured on one reader.
Other features and benefits include:
- Capture flash assays with ease
-
Reduce background noise
-
Increase fluorescence performance
... Read More | Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. These robust readers have been placed in labs from Antarctica to the International Space Station.
With optimized reagents, validation tools, and industry-leading SoftMax® Pro Software, they provide consistent performance.
Patented optimization - The patented AutoPMT optimization of the SpectraMax M5 reader adjusts the fluorescence detector to each sample well's concentration and normalizes the raw data, extending the dynamic range of assays.
IQ/OQ/PM Services - Qualify Molecular Devices microplate readers in GLP or GMP environments with our IQ/OQ/PM Services to preserve the documentation of services in a compliant format that can be accessed remotely.
Validation tools - Extensive suite of validation tools reduces the cost and time of validation by 50% as compared to using multiple platforms to collect and analyze data.
Compliance software - SoftMax Pro GxP Software extends data acquisition and analysis solution into regulated laboratories working under GMP, GLP, and 21 CFR Part 11 for secure electronic records.
Other features and benefits include: - - Assay flexibility
- Better absorbance accuracy
- Increased throughput
... Read More | The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget friendly solution that gives you exactly what you need when you need it. With three modes of detection for UV-Vis absorbance, fluorescence and luminescence, the SpectraMax Mini reader is user upgradeable - from 2 to 3 modes, The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget friendly solution that gives you exactly what you need when you need it. With three modes of detection for UV-Vis absorbance, fluorescence and luminescence, the SpectraMax Mini reader is user upgradeable - from 2 to 3 modes, providing researchers with a versatile instrument that does not compromise on sensitivity or performance. Included SoftMax® Pro Software enables rapid data generation and analysis helping you achieve more in less time.
Features:
- Industry-leading software - Enjoy an extensive library of protocols, advanced reader control, and easy data management and analysis with our best-in-class SoftMax Pro Software.
- Expanded wavelength range - Xenon flash lamps allow you to excite samples in the UV range where halogen does not.
- Approachable design - Effortless functionality provides users with everything they need to run their most crucial applications quickly and without complications.
- AutoPMT technology - Our AutoPMT feature allows a wide range of concentrations to be prepared and read on one plate, avoiding saturation (or the loss of signal) and saving you time and money.
... Read More | Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique allowing you to read up to seven logs of sample concentration in a single pass of a plate without manual gain adjustment.
Configuration changes in minutes -
Adding new read modes is fast and simple with the detection cartridge system. Order additional detection cartridges as your application needs change, and install them by yourself in under two minutes.
Increased dynamic range and sensitivity -
Use predefined reductions, columns, and summary formulas, or create custom calculations. Analyze EC50 and Z-factors to identify assay quality, and graph results with over 21 curve fit options.
Other features and benefits include:
- Get automatic Z-height optimization
-
Eliminate manual gain adjustment
-
Tailor your data analysis
... Read More |
Reading Modes | Absorbance Photometric, Fluorescence Intensity, Fluorescence Polarization, Time-resolved Fluorescence, Luminescence | Absorbance, Fluorescence (top/bottom read), Luminescence (top read), Time-Resolved Fluorescence (top read), Fluorescence Polarization (top read), HTRF (top read), AlphaScreen (top read) | Absorbance, Fluorescence, Luminescence,Time-Resolved Fluorescence, Fluorescence Polarization, HTRF | UV-Vis absorbance, Fluorescence, and Luminescence | Endpoint reading, Kinetic reading, Well Area Scanning |