Description | Filterless readers provide consistent results with steady temperature regulation.
The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Both Filterless readers provide consistent results with steady temperature regulation.
The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Both readers feature an 8-channel read head for fast reads and a subset feature our patented PathCheck™ Sensor. The temperature independent PathCheck sensor automatically normalizes and ensures accurate absorbance values by detecting pipetting errors. Combined with a wide application base, industry-leading SoftMax® Pro Software and validation tools, these readers fit in every lab and every budget.
Pipetting errors eliminated - This reader utilizes Molecular Devices' patented PathCheck® Sensor to measure the depth (optical pathlength) of samples in a microplate. It also allows for the elimination of standard curves.
Optimized optical path - The reader’s unique quartz fiber optic system minimizes stray light for precise readings across a microplate. The spectral resolution ensures accuracy of DNA absorbance measurements.
Eight-channel optics - The optical design of the reader mimics a dual-beam spectrophotometer. Each well has its own sample beam and reference detector. The eight-channel system delivers both precision and speed across the microplate.
Dual wavelength reads - The reader delivers high performance with round-bottom, flat-bottom or half-area well plates. Dual wavelength readings report the actual absorbance at each wavelength making data analysis convenient.
Flexibility to read a variety of plate formats - SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate.
Validation made easy - Verify the accuracy of your absorbance measurements with the SpectraTest® ABS1 Absorbance Validation Plate, using NIST-traceable standards. Testing can be done in your own lab, on your own schedule.
Other features and benefits include: - Eliminate filters
- Get consistent results
- Integrate with ease
... Read More | Eight filter options provide simplified assay setup.
The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. The reader measures Eight filter options provide simplified assay setup.
The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. The reader measures both flat and round 96-well microplates and ensures accuracy by automatic lamp calibration prior to each reading.
Easy data visualization - Powerful curve fitting protocols and statistical analysis features are included for easy visualization of acquired data as grayscale or color map images, 3D graphs, kinetic plots, or reaction rates.
Compact design - The small footprint and low profile saves space on the bench.
Other features and benefits include: - Cover a wide range of applications
- Simplify assay setup
- Customize Options
... Read More | Affordability and unmatched assay performance in filter-based microplate readers.
The FilterMax™ F3 and F5 Multi-Mode Microplate Readers offer a wide set of features at an affordable price-to-performance ratio. They provide absorbance, fluorescence, glow luminescence, and other read modes for Affordability and unmatched assay performance in filter-based microplate readers.
The FilterMax™ F3 and F5 Multi-Mode Microplate Readers offer a wide set of features at an affordable price-to-performance ratio. They provide absorbance, fluorescence, glow luminescence, and other read modes for programmable endpoint, kinetic, multiple-wavelength linear scan and area scan measurements.
Visible absorbance -
This reader provides visible absorbance, top-reading fluorescence intensity, and glow luminescence modes in 96- to 384-well plates with wavelength selection options from 340-650 nm.
UV and visible absorbance -
This reader provides UV and visible absorbance, top and bottom fluorescence intensity, glow luminescence, FP, and TRF modes in 6- to 1536-well plates with wavelength selection options from 230-750 nm.
Other features and benefits include:
- Get great performance with LEDs
-
Count single photons
-
Get tailored data analysis
... Read More | NFC-based personalization and enhanced touchscreen workflows provide walk-up usability
The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET,NFC-based personalization and enhanced touchscreen workflows provide walk-up usability
The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection.
With optimized reagents, option to operate the readers using the touchscreen or a computer, and industry-leading SoftMax® Pro Software, the readers provide an all access pass for breakthrough research.
QuickSync - The QuickSync feature pushes data to any computer within the same network and delivers data in an Excel-compatible format.
Flexible temperature control - Simple-to-use temperature control adjusts the experiment's conditions from ambient up to 66°C.
Automatic filter identification - Using NFC tags, the SpectraMax iD5 reader automatically detects the wavelength properties of each filter in addition to the filter slide configuration, eliminating confusion and the need for manual information entry.
Enhanced security - The SoftMax® Touch Software secures user accounts with PIN- or NFC-protection with a lock screen option. Data is stored on the reader’s hard drive ensuring security even after transfer to a computer.
Hybrid optical system - The SpectraMax iD5 reader provides the flexibility to set up experiments using filters, or a monochromator in 1 nm increments, or a hybrid mix of monochromator and filter-based wavelength selection.
Flash assays captured with ease - The SpectraMax Injector System with SmartInject™ Technology features low dead volume (10 µL), overflow protection, and ensures equal mixing across the plate for high-precision experiments.
Other features and benefits include: - Personalize workflows
- • Simplify tasks
- • Reduce background noise
... Read More | Designed specifically for the SpectraMax® i3 Multi-Mode Detection Platform, the SpectraMax® MiniMaxTM imaging cytometer option adds first-of-its-kind cellular imaging capability to a microplate reader. The upgradable option makes cytometry more accessible to a wider audience, providing researchers Designed specifically for the SpectraMax® i3 Multi-Mode Detection Platform, the SpectraMax® MiniMaxTM imaging cytometer option adds first-of-its-kind cellular imaging capability to a microplate reader. The upgradable option makes cytometry more accessible to a wider audience, providing researchers with cellular analysis capability without the need for investment in complex imaging systems. With brightfield and fluorescent imaging modes, the imaging cytometry option enables quick inspection of cells and provides insight into phenotypic changes that are important for understanding cytotoxicity, cell proliferation, and protein expression.
Features - Simple workflow: Cell and whole-well assays in a small footprint
- More data: Multi-parametric cell-based assays with brightfield and fluorescent modes
- Familiar software: Set up, image and analyze cells in a snap using SoftMax® Pro Software
- Higher sensitivity: Use fewer and or less fluorescent cells compared to whole-well measurements
- Lower variance: Normalize readings with number of cells in a well
... Read More |