Description | Multi-wavelength measurement without filters.
The Gemini™ XPS and EM Microplate Readers with dual monochromators provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Multiple-point well scanning optimizes cell-based assay Multi-wavelength measurement without filters.
The Gemini™ XPS and EM Microplate Readers with dual monochromators provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Multiple-point well scanning optimizes cell-based assay sensitivity. Comparison of relative fluorescence units (RFUs) between samples is allowed by a unique calibration against an internal standard. Temperature-sensitive reactions are monitored with consistent temperature regulation from ambient to 45°C.
Top-read capability -
The top-reading Gemini XPS Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.
Top- and bottom-read capability -
The top- and bottom-reading Gemini EM Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.
Other features and benefits include:
- Eliminate changing out filters
-
Measure more accurately
-
Avoid losing high signal
... Read More | Demonstrating that cell lines are monoclonal – or that a gene was edited as expected – can be a time-consuming and highly-subjective process when relying on conventional technologies. The CloneSelect® Imager and CloneSelect® Imager FL are a high-throughput automated solutions for imaging and Demonstrating that cell lines are monoclonal – or that a gene was edited as expected – can be a time-consuming and highly-subjective process when relying on conventional technologies. The CloneSelect® Imager and CloneSelect® Imager FL are a high-throughput automated solutions for imaging and analyzing mammalian cells. Tracking the formation of a colony from a single cell is effortless as barcoded plates are tracked over time. Automated acquisition and analysis provides accurate, objective, and consistent results.
With high-resolution white light imaging, the CloneSelect Imager provides automated confluence, monoclonality assurance and industry leading acquisition times with the ability to image a 96-well plate in under two minutes.
The CloneSelect Imager FL features high contrast multichannel fluorescent and white light imaging that allows for accurate single cell detection and proof of monoclonality at day 0. Streamline your workflow with comparative confluence assays to identify and verify gene edits.
Features :
- White light and fluorescent imaging -
Image every well in every plate with rapid acquisition times with label-free white light. Multichannel fluorescence imaging provides additional confidence of monoclonality and comparative confluence assays (red vs green). -
Data tools to accelerate research timelines -
The software automatically calculates confluence measurements and generates growth curves, heatmaps, and image montages. Measurements for every well are automatically tracked over time. Streamline multiple steps (imaging, sample tracking, data analysis and report generation) in the cell line development workflow for IND filing. -
Quickly image a variety of plate formats and cell types -
Image a 96-well plate in under two minutes. Compatible with adherent or settled suspension cell types such as CHO, HEK, hybridomas, iPSCs, and many other cell types. -
Intelligent analysis with easy-to-use software -
The software automatically calculates confluence for each imaging time point. Growth curve, image montage, total growth, and mean rate are generated automatically and are exportable. Guided software user interface allows for simple 1-hour training. -
High-resolution images -
High-speed fluorescence and high-resolution white light imaging with accurate detection of single cells including debris. Image visualization and data tracking over multiple days. -
Custom automation options -
The Automation and Customization Team offers a variety of custom services from robotic plate loading to fully automated workstations with liquid handling and incubation. We have built out custom automated work cells with the CloneSelect Imager for iPSC workflows, full assay systems and drug toxicity and characterization research. ... Read More | Filterless readers provide consistent results with steady temperature regulation.
The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Both Filterless readers provide consistent results with steady temperature regulation.
The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Both readers feature an 8-channel read head for fast reads and a subset feature our patented PathCheck™ Sensor. The temperature independent PathCheck sensor automatically normalizes and ensures accurate absorbance values by detecting pipetting errors. Combined with a wide application base, industry-leading SoftMax® Pro Software and validation tools, these readers fit in every lab and every budget.
Pipetting errors eliminated - This reader utilizes Molecular Devices' patented PathCheck® Sensor to measure the depth (optical pathlength) of samples in a microplate. It also allows for the elimination of standard curves.
Optimized optical path - The reader’s unique quartz fiber optic system minimizes stray light for precise readings across a microplate. The spectral resolution ensures accuracy of DNA absorbance measurements.
Eight-channel optics - The optical design of the reader mimics a dual-beam spectrophotometer. Each well has its own sample beam and reference detector. The eight-channel system delivers both precision and speed across the microplate.
Dual wavelength reads - The reader delivers high performance with round-bottom, flat-bottom or half-area well plates. Dual wavelength readings report the actual absorbance at each wavelength making data analysis convenient.
Flexibility to read a variety of plate formats - SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate.
Validation made easy - Verify the accuracy of your absorbance measurements with the SpectraTest® ABS1 Absorbance Validation Plate, using NIST-traceable standards. Testing can be done in your own lab, on your own schedule.
Other features and benefits include: - Eliminate filters
- Get consistent results
- Integrate with ease
... Read More | The SpectraMax® i3 Multi-Mode Detection Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader The SpectraMax® i3 Multi-Mode Detection Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader applications, protecting your intial investment. As new assays are developed or your needs change, simply add a cartridge or the SpectraMax® MiniMax™ Imaging Cytometer option as opposed to buying a brand new system.
Features - User-Upgradeability Expand the 3-mode base system with additional application cartridges for FP, HTRF®, AlphaScreen® assays, and cellular imaging
- SpectraMax® MiniMaxTM Imaging Cytometer simplifies complex imaging workflow by visualizing cell morphology changes on top of well-based intensity readings
- Spectral FusionTM Illumination delivers a high-powered, full spectrum light source for increased fluorescence performance across the entire excitation range
- Expanded Dynamic Range: sophisticated engineering delivers optimal sensitivity and maximizes signal range
- SoftMax® Pro Microplate Data Acquisition & Analysis Software: Industry-leading SoftMax Pro Software streamlines complex data analysis with over 140 built-in protocols, effectively eliminating the need for additional software. Additional tools for regulatory compliance are included in SoftMax Pro GxP Software
... Read More | Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes.
With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user-configurable detection modules, the reader provides you with the ability to explore cellular pathways and protein expression on one microplate reader.
User-configurable applications -
User-configurable detection modules expand the reader’s detection capabilities to include AlphaScreen, Time-Resolved Fluorescence, HTRF, fast kinetics with injectors, western blot detection, and more.
No-stain cell analysis -
The StainFree™ Cell Detection Algorithm for brightfield cell segmentation enables cell counting and confluency measurement without destructive stains, simplifying the cell counting workflow.
Multi-channel functionality -
Two fluorescence detection channels on the MiniMax cytometer enable the analysis of cell viability or cell toxicity assays, including ratiometric assays like live-dead and transfection efficiency.
Cellular pathway analysis -
Cell confluence and cell viability imaging, western blot analysis, and quantitation of nucleic acids and protein, can be captured on one reader.
Other features and benefits include:
- Capture flash assays with ease
-
Reduce background noise
-
Increase fluorescence performance
... Read More |