Description | Sets the enduring standard for microplate analysis using filters for end-point absorbance measurements.
The EMax® Endpoint ELISA Microplate Reader from Molecular Devices, one of the pioneers in microplate detection, offers a ruggedly simple approach to dedicated endpoint assays. A staggeringSets the enduring standard for microplate analysis using filters for end-point absorbance measurements.
The EMax® Endpoint ELISA Microplate Reader from Molecular Devices, one of the pioneers in microplate detection, offers a ruggedly simple approach to dedicated endpoint assays. A staggering mean time between failure (MTBF) of 20,000 hours is achieved by 97 independent and stationary fiber optics so that the microplate remains stationary during the entire reading cycle, reducing the number of moving parts. No optical alignment needed during the lifetime of the instrument!
Through sequential, single-well illumination, 100% of the available light is directed to each well through the optical fibers to achieve linearity to higher optical densities (ODs) and optimal signal-to-noise ratios. At 5 seconds to read a 96-well endpoint assay, the EMax Microplate Reader has both the speed and performance to carry a heavy workload.
The EMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices.
EMax Microplate Readers can be operated as a stand-alone instrument and is also supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software.
Features - Solid Performance for Dedicated Absorbance
- Enabling Features
- Read up to 2 wavelengths in endpoint absorbance for 96-well plates.
- Mix samples in microplate wells by user-programmable Automix feature.
- Operate without an attached computer using the onboard microprocessor.
- Add assay flexibility with additional filters.
- Comprehensive Reader Validation
... Read More | Eight filter options provide simplified assay setup.
The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. The reader measures Eight filter options provide simplified assay setup.
The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. The reader measures both flat and round 96-well microplates and ensures accuracy by automatic lamp calibration prior to each reading.
Easy data visualization - Powerful curve fitting protocols and statistical analysis features are included for easy visualization of acquired data as grayscale or color map images, 3D graphs, kinetic plots, or reaction rates.
Compact design - The small footprint and low profile saves space on the bench.
Other features and benefits include: - Cover a wide range of applications
- Simplify assay setup
- Customize Options
... Read More | Filterless readers provide consistent results with steady temperature regulation.
The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Both Filterless readers provide consistent results with steady temperature regulation.
The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Both readers feature an 8-channel read head for fast reads and a subset feature our patented PathCheck™ Sensor. The temperature independent PathCheck sensor automatically normalizes and ensures accurate absorbance values by detecting pipetting errors. Combined with a wide application base, industry-leading SoftMax® Pro Software and validation tools, these readers fit in every lab and every budget.
Pipetting errors eliminated - This reader utilizes Molecular Devices' patented PathCheck® Sensor to measure the depth (optical pathlength) of samples in a microplate. It also allows for the elimination of standard curves.
Optimized optical path - The reader’s unique quartz fiber optic system minimizes stray light for precise readings across a microplate. The spectral resolution ensures accuracy of DNA absorbance measurements.
Eight-channel optics - The optical design of the reader mimics a dual-beam spectrophotometer. Each well has its own sample beam and reference detector. The eight-channel system delivers both precision and speed across the microplate.
Dual wavelength reads - The reader delivers high performance with round-bottom, flat-bottom or half-area well plates. Dual wavelength readings report the actual absorbance at each wavelength making data analysis convenient.
Flexibility to read a variety of plate formats - SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate.
Validation made easy - Verify the accuracy of your absorbance measurements with the SpectraTest® ABS1 Absorbance Validation Plate, using NIST-traceable standards. Testing can be done in your own lab, on your own schedule.
Other features and benefits include: - Eliminate filters
- Get consistent results
- Integrate with ease
... Read More | Multi-wavelength measurement without filters.
The Gemini™ XPS and EM Microplate Readers with dual monochromators provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Multiple-point well scanning optimizes cell-based assay Multi-wavelength measurement without filters.
The Gemini™ XPS and EM Microplate Readers with dual monochromators provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Multiple-point well scanning optimizes cell-based assay sensitivity. Comparison of relative fluorescence units (RFUs) between samples is allowed by a unique calibration against an internal standard. Temperature-sensitive reactions are monitored with consistent temperature regulation from ambient to 45°C.
Top-read capability -
The top-reading Gemini XPS Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.
Top- and bottom-read capability -
The top- and bottom-reading Gemini EM Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.
Other features and benefits include:
- Eliminate changing out filters
-
Measure more accurately
-
Avoid losing high signal
... Read More | Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique allowing you to read up to seven logs of sample concentration in a single pass of a plate without manual gain adjustment.
Configuration changes in minutes -
Adding new read modes is fast and simple with the detection cartridge system. Order additional detection cartridges as your application needs change, and install them by yourself in under two minutes.
Increased dynamic range and sensitivity -
Use predefined reductions, columns, and summary formulas, or create custom calculations. Analyze EC50 and Z-factors to identify assay quality, and graph results with over 21 curve fit options.
Other features and benefits include:
- Get automatic Z-height optimization
-
Eliminate manual gain adjustment
-
Tailor your data analysis
... Read More |