Description | Sets the enduring standard for microplate analysis using filters for end-point absorbance measurements.
The EMax® Endpoint ELISA Microplate Reader from Molecular Devices, one of the pioneers in microplate detection, offers a ruggedly simple approach to dedicated endpoint assays. A staggeringSets the enduring standard for microplate analysis using filters for end-point absorbance measurements.
The EMax® Endpoint ELISA Microplate Reader from Molecular Devices, one of the pioneers in microplate detection, offers a ruggedly simple approach to dedicated endpoint assays. A staggering mean time between failure (MTBF) of 20,000 hours is achieved by 97 independent and stationary fiber optics so that the microplate remains stationary during the entire reading cycle, reducing the number of moving parts. No optical alignment needed during the lifetime of the instrument!
Through sequential, single-well illumination, 100% of the available light is directed to each well through the optical fibers to achieve linearity to higher optical densities (ODs) and optimal signal-to-noise ratios. At 5 seconds to read a 96-well endpoint assay, the EMax Microplate Reader has both the speed and performance to carry a heavy workload.
The EMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices.
EMax Microplate Readers can be operated as a stand-alone instrument and is also supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software.
Features - Solid Performance for Dedicated Absorbance
- Enabling Features
- Read up to 2 wavelengths in endpoint absorbance for 96-well plates.
- Mix samples in microplate wells by user-programmable Automix feature.
- Operate without an attached computer using the onboard microprocessor.
- Add assay flexibility with additional filters.
- Comprehensive Reader Validation
... Read More | NFC-based personalization and enhanced touchscreen workflows provide walk-up usability
The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET,NFC-based personalization and enhanced touchscreen workflows provide walk-up usability
The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection.
With optimized reagents, option to operate the readers using the touchscreen or a computer, and industry-leading SoftMax® Pro Software, the readers provide an all access pass for breakthrough research.
QuickSync - The QuickSync feature pushes data to any computer within the same network and delivers data in an Excel-compatible format.
Flexible temperature control - Simple-to-use temperature control adjusts the experiment's conditions from ambient up to 66°C.
Automatic filter identification - Using NFC tags, the SpectraMax iD5 reader automatically detects the wavelength properties of each filter in addition to the filter slide configuration, eliminating confusion and the need for manual information entry.
Enhanced security - The SoftMax® Touch Software secures user accounts with PIN- or NFC-protection with a lock screen option. Data is stored on the reader’s hard drive ensuring security even after transfer to a computer.
Hybrid optical system - The SpectraMax iD5 reader provides the flexibility to set up experiments using filters, or a monochromator in 1 nm increments, or a hybrid mix of monochromator and filter-based wavelength selection.
Flash assays captured with ease - The SpectraMax Injector System with SmartInject™ Technology features low dead volume (10 µL), overflow protection, and ensures equal mixing across the plate for high-precision experiments.
Other features and benefits include: - Personalize workflows
- • Simplify tasks
- • Reduce background noise
... Read More | Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. These robust readers have been placed in labs from Antarctica to the International Space Station.
With optimized reagents, validation tools, and industry-leading SoftMax® Pro Software, they provide consistent performance.
Patented optimization - The patented AutoPMT optimization of the SpectraMax M5 reader adjusts the fluorescence detector to each sample well's concentration and normalizes the raw data, extending the dynamic range of assays.
IQ/OQ/PM Services - Qualify Molecular Devices microplate readers in GLP or GMP environments with our IQ/OQ/PM Services to preserve the documentation of services in a compliant format that can be accessed remotely.
Validation tools - Extensive suite of validation tools reduces the cost and time of validation by 50% as compared to using multiple platforms to collect and analyze data.
Compliance software - SoftMax Pro GxP Software extends data acquisition and analysis solution into regulated laboratories working under GMP, GLP, and 21 CFR Part 11 for secure electronic records.
Other features and benefits include: - - Assay flexibility
- Better absorbance accuracy
- Increased throughput
... Read More | Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique allowing you to read up to seven logs of sample concentration in a single pass of a plate without manual gain adjustment.
Configuration changes in minutes -
Adding new read modes is fast and simple with the detection cartridge system. Order additional detection cartridges as your application needs change, and install them by yourself in under two minutes.
Increased dynamic range and sensitivity -
Use predefined reductions, columns, and summary formulas, or create custom calculations. Analyze EC50 and Z-factors to identify assay quality, and graph results with over 21 curve fit options.
Other features and benefits include:
- Get automatic Z-height optimization
-
Eliminate manual gain adjustment
-
Tailor your data analysis
... Read More | Enables precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility.
Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for Enables precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility.
Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340 nm - 850 nm). Narrow bandwidths deliver increased accuracy and enhanced peak resolution. Never order or replace filters to optimize an assay again!
A patented multichannel optical design mimics a dual-beam spectrophotometer, measures each sample in the plate directly, and eliminates error due to variations in light output between optical fibers on other instruments for more reliable reporting. The eight-channel system delivers high precision and speed when reading 96-well microplates for single endpoint measurements and kinetic assay data gathered over time.
The VersaMax Microplate Reader is supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software. Additionally, the VersaMax Microplate Reader can be seamlessly integrated with the StakMax® Microlate Handling Stacker through the SoftMax Pro Software.
Features - Enabling Assays without Compromise
- Measuring Accurately and Reproducibly
- Comprehensive Reader Validation
- Automating with Ease
... Read More |