Description | The SpectraMax® i3 Multi-Mode Detection Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader The SpectraMax® i3 Multi-Mode Detection Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader applications, protecting your intial investment. As new assays are developed or your needs change, simply add a cartridge or the SpectraMax® MiniMax™ Imaging Cytometer option as opposed to buying a brand new system.
Features - User-Upgradeability Expand the 3-mode base system with additional application cartridges for FP, HTRF®, AlphaScreen® assays, and cellular imaging
- SpectraMax® MiniMaxTM Imaging Cytometer simplifies complex imaging workflow by visualizing cell morphology changes on top of well-based intensity readings
- Spectral FusionTM Illumination delivers a high-powered, full spectrum light source for increased fluorescence performance across the entire excitation range
- Expanded Dynamic Range: sophisticated engineering delivers optimal sensitivity and maximizes signal range
- SoftMax® Pro Microplate Data Acquisition & Analysis Software: Industry-leading SoftMax Pro Software streamlines complex data analysis with over 140 built-in protocols, effectively eliminating the need for additional software. Additional tools for regulatory compliance are included in SoftMax Pro GxP Software
... Read More | Multi-wavelength measurement without filters.
The Gemini™ XPS and EM Microplate Readers with dual monochromators provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Multiple-point well scanning optimizes cell-based assay Multi-wavelength measurement without filters.
The Gemini™ XPS and EM Microplate Readers with dual monochromators provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Multiple-point well scanning optimizes cell-based assay sensitivity. Comparison of relative fluorescence units (RFUs) between samples is allowed by a unique calibration against an internal standard. Temperature-sensitive reactions are monitored with consistent temperature regulation from ambient to 45°C.
Top-read capability -
The top-reading Gemini XPS Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.
Top- and bottom-read capability -
The top- and bottom-reading Gemini EM Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.
Other features and benefits include:
- Eliminate changing out filters
-
Measure more accurately
-
Avoid losing high signal
... Read More | Flash and glow luminescence detection in an upgradeable platform.
The SpectraMax® L Microplate Reader measures flash and glow luminescence assays in both 96- and 384-well plates. It is upgradeable to include a barcode reader, programmable injectors, and dual-channel configurations for a 2-fold Flash and glow luminescence detection in an upgradeable platform.
The SpectraMax® L Microplate Reader measures flash and glow luminescence assays in both 96- and 384-well plates. It is upgradeable to include a barcode reader, programmable injectors, and dual-channel configurations for a 2-fold increase for medium throughput. The high sensitivity, low-noise photomultiplier tubes (PMTs), and variable-volume injector configuration make this reader ideal for fast kinetic assays requiring continuous monitoring during injection and measurement.
Reduced noise -
Ultra-fast photon counting technology amplifies the PMT signal with a fast pulse amplifier. This reduced noise capability enables a higher signal-to-noise ratio and low crosstalk.
PMT calibration -
The automatic PMT calibration method is based on readings of 4 internal LEDs at 395, 470, 527, and 570 nm. The manual PMT calibration method is based on readings of 4 wells from the assay.
Other features and benefits include:
- Detect all samples
-
Get 2-fold improvement in speed
-
Automate injector workflows
... Read More | Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. These robust readers have been placed in labs from Antarctica to the International Space Station.
With optimized reagents, validation tools, and industry-leading SoftMax® Pro Software, they provide consistent performance.
Patented optimization - The patented AutoPMT optimization of the SpectraMax M5 reader adjusts the fluorescence detector to each sample well's concentration and normalizes the raw data, extending the dynamic range of assays.
IQ/OQ/PM Services - Qualify Molecular Devices microplate readers in GLP or GMP environments with our IQ/OQ/PM Services to preserve the documentation of services in a compliant format that can be accessed remotely.
Validation tools - Extensive suite of validation tools reduces the cost and time of validation by 50% as compared to using multiple platforms to collect and analyze data.
Compliance software - SoftMax Pro GxP Software extends data acquisition and analysis solution into regulated laboratories working under GMP, GLP, and 21 CFR Part 11 for secure electronic records.
Other features and benefits include: - - Assay flexibility
- Better absorbance accuracy
- Increased throughput
... Read More | Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique allowing you to read up to seven logs of sample concentration in a single pass of a plate without manual gain adjustment.
Configuration changes in minutes -
Adding new read modes is fast and simple with the detection cartridge system. Order additional detection cartridges as your application needs change, and install them by yourself in under two minutes.
Increased dynamic range and sensitivity -
Use predefined reductions, columns, and summary formulas, or create custom calculations. Analyze EC50 and Z-factors to identify assay quality, and graph results with over 21 curve fit options.
Other features and benefits include:
- Get automatic Z-height optimization
-
Eliminate manual gain adjustment
-
Tailor your data analysis
... Read More |