Description | Affordability and unmatched assay performance in filter-based microplate readers.
The FilterMax™ F3 and F5 Multi-Mode Microplate Readers offer a wide set of features at an affordable price-to-performance ratio. They provide absorbance, fluorescence, glow luminescence, and other read modes for Affordability and unmatched assay performance in filter-based microplate readers.
The FilterMax™ F3 and F5 Multi-Mode Microplate Readers offer a wide set of features at an affordable price-to-performance ratio. They provide absorbance, fluorescence, glow luminescence, and other read modes for programmable endpoint, kinetic, multiple-wavelength linear scan and area scan measurements.
Visible absorbance -
This reader provides visible absorbance, top-reading fluorescence intensity, and glow luminescence modes in 96- to 384-well plates with wavelength selection options from 340-650 nm.
UV and visible absorbance -
This reader provides UV and visible absorbance, top and bottom fluorescence intensity, glow luminescence, FP, and TRF modes in 6- to 1536-well plates with wavelength selection options from 230-750 nm.
Other features and benefits include:
- Get great performance with LEDs
-
Count single photons
-
Get tailored data analysis
... Read More | Designed specifically for the SpectraMax® i3 Multi-Mode Detection Platform, the SpectraMax® MiniMaxTM imaging cytometer option adds first-of-its-kind cellular imaging capability to a microplate reader. The upgradable option makes cytometry more accessible to a wider audience, providing researchers Designed specifically for the SpectraMax® i3 Multi-Mode Detection Platform, the SpectraMax® MiniMaxTM imaging cytometer option adds first-of-its-kind cellular imaging capability to a microplate reader. The upgradable option makes cytometry more accessible to a wider audience, providing researchers with cellular analysis capability without the need for investment in complex imaging systems. With brightfield and fluorescent imaging modes, the imaging cytometry option enables quick inspection of cells and provides insight into phenotypic changes that are important for understanding cytotoxicity, cell proliferation, and protein expression.
Features - Simple workflow: Cell and whole-well assays in a small footprint
- More data: Multi-parametric cell-based assays with brightfield and fluorescent modes
- Familiar software: Set up, image and analyze cells in a snap using SoftMax® Pro Software
- Higher sensitivity: Use fewer and or less fluorescent cells compared to whole-well measurements
- Lower variance: Normalize readings with number of cells in a well
... Read More | Enables precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility.
Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for Enables precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility.
Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340 nm - 850 nm). Narrow bandwidths deliver increased accuracy and enhanced peak resolution. Never order or replace filters to optimize an assay again!
A patented multichannel optical design mimics a dual-beam spectrophotometer, measures each sample in the plate directly, and eliminates error due to variations in light output between optical fibers on other instruments for more reliable reporting. The eight-channel system delivers high precision and speed when reading 96-well microplates for single endpoint measurements and kinetic assay data gathered over time.
The VersaMax Microplate Reader is supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software. Additionally, the VersaMax Microplate Reader can be seamlessly integrated with the StakMax® Microlate Handling Stacker through the SoftMax Pro Software.
Features - Enabling Assays without Compromise
- Measuring Accurately and Reproducibly
- Comprehensive Reader Validation
- Automating with Ease
... Read More | The VMax® Kinetic ELISA Microplate Reader, the first of its kind for monitoring reactions over time, opened the door to enzyme assays and continues to be the workhorse of the laboratory environment. Based on a rugged, simple design, the VMax Absorbance Microplate Reader offers a mean time between The VMax® Kinetic ELISA Microplate Reader, the first of its kind for monitoring reactions over time, opened the door to enzyme assays and continues to be the workhorse of the laboratory environment. Based on a rugged, simple design, the VMax Absorbance Microplate Reader offers a mean time between failure (MTBF) of 20,000 hours with 97 independent and stationary fiber optics so that the microplate remains stationary during the entire reading cycle, reducing the number of moving parts that can wear and need replacement.
Through sequential, single-well illumination, 100% of the available light is directed to each well through the optical fibers to achieve linearity to higher optical densities (ODs) and optimal signal-to-noise ratios. At 5 seconds to read a 96-well endpoint assay or a 5 second minimum interval between kinetic reads, the VMax Microplate Reader has both speed and performance.
The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices.
VMax Microplate Readers can be operated as stand-alone instruments and are also supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software.
Features - Extend uptime with an estimated 20,000 hour mean time between failure
- Maximize assay signal-to-noise ratios through a unique optical system that directs all available light to each well
- Achieve higher throughput with a 5 second microplate read time
- Read up to 2 wavelengths in endpoint or kinetic absorbance for 96-well plates
- Mix samples in microplate wells by user-programmable Automix feature
- Operate without an attached computer using the onboard microprocessor
- Add assay flexibility with additional filters
... Read More |