Description | Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes.
With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user-configurable detection modules, the reader provides you with the ability to explore cellular pathways and protein expression on one microplate reader.
User-configurable applications -
User-configurable detection modules expand the reader’s detection capabilities to include AlphaScreen, Time-Resolved Fluorescence, HTRF, fast kinetics with injectors, western blot detection, and more.
No-stain cell analysis -
The StainFree™ Cell Detection Algorithm for brightfield cell segmentation enables cell counting and confluency measurement without destructive stains, simplifying the cell counting workflow.
Multi-channel functionality -
Two fluorescence detection channels on the MiniMax cytometer enable the analysis of cell viability or cell toxicity assays, including ratiometric assays like live-dead and transfection efficiency.
Cellular pathway analysis -
Cell confluence and cell viability imaging, western blot analysis, and quantitation of nucleic acids and protein, can be captured on one reader.
Other features and benefits include:
- Capture flash assays with ease
-
Reduce background noise
-
Increase fluorescence performance
... Read More | Demonstrating that cell lines are monoclonal – or that a gene was edited as expected – can be a time-consuming and highly-subjective process when relying on conventional technologies. The CloneSelect® Imager and CloneSelect® Imager FL are a high-throughput automated solutions for imaging and Demonstrating that cell lines are monoclonal – or that a gene was edited as expected – can be a time-consuming and highly-subjective process when relying on conventional technologies. The CloneSelect® Imager and CloneSelect® Imager FL are a high-throughput automated solutions for imaging and analyzing mammalian cells. Tracking the formation of a colony from a single cell is effortless as barcoded plates are tracked over time. Automated acquisition and analysis provides accurate, objective, and consistent results.
With high-resolution white light imaging, the CloneSelect Imager provides automated confluence, monoclonality assurance and industry leading acquisition times with the ability to image a 96-well plate in under two minutes.
The CloneSelect Imager FL features high contrast multichannel fluorescent and white light imaging that allows for accurate single cell detection and proof of monoclonality at day 0. Streamline your workflow with comparative confluence assays to identify and verify gene edits.
Features :
- White light and fluorescent imaging -
Image every well in every plate with rapid acquisition times with label-free white light. Multichannel fluorescence imaging provides additional confidence of monoclonality and comparative confluence assays (red vs green). -
Data tools to accelerate research timelines -
The software automatically calculates confluence measurements and generates growth curves, heatmaps, and image montages. Measurements for every well are automatically tracked over time. Streamline multiple steps (imaging, sample tracking, data analysis and report generation) in the cell line development workflow for IND filing. -
Quickly image a variety of plate formats and cell types -
Image a 96-well plate in under two minutes. Compatible with adherent or settled suspension cell types such as CHO, HEK, hybridomas, iPSCs, and many other cell types. -
Intelligent analysis with easy-to-use software -
The software automatically calculates confluence for each imaging time point. Growth curve, image montage, total growth, and mean rate are generated automatically and are exportable. Guided software user interface allows for simple 1-hour training. -
High-resolution images -
High-speed fluorescence and high-resolution white light imaging with accurate detection of single cells including debris. Image visualization and data tracking over multiple days. -
Custom automation options -
The Automation and Customization Team offers a variety of custom services from robotic plate loading to fully automated workstations with liquid handling and incubation. We have built out custom automated work cells with the CloneSelect Imager for iPSC workflows, full assay systems and drug toxicity and characterization research. ... Read More | Eight filter options provide simplified assay setup.
The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. The reader measures Eight filter options provide simplified assay setup.
The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. The reader measures both flat and round 96-well microplates and ensures accuracy by automatic lamp calibration prior to each reading.
Easy data visualization - Powerful curve fitting protocols and statistical analysis features are included for easy visualization of acquired data as grayscale or color map images, 3D graphs, kinetic plots, or reaction rates.
Compact design - The small footprint and low profile saves space on the bench.
Other features and benefits include: - Cover a wide range of applications
- Simplify assay setup
- Customize Options
... Read More | Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. These robust readers have been placed in labs from Antarctica to the International Space Station.
With optimized reagents, validation tools, and industry-leading SoftMax® Pro Software, they provide consistent performance.
Patented optimization - The patented AutoPMT optimization of the SpectraMax M5 reader adjusts the fluorescence detector to each sample well's concentration and normalizes the raw data, extending the dynamic range of assays.
IQ/OQ/PM Services - Qualify Molecular Devices microplate readers in GLP or GMP environments with our IQ/OQ/PM Services to preserve the documentation of services in a compliant format that can be accessed remotely.
Validation tools - Extensive suite of validation tools reduces the cost and time of validation by 50% as compared to using multiple platforms to collect and analyze data.
Compliance software - SoftMax Pro GxP Software extends data acquisition and analysis solution into regulated laboratories working under GMP, GLP, and 21 CFR Part 11 for secure electronic records.
Other features and benefits include: - - Assay flexibility
- Better absorbance accuracy
- Increased throughput
... Read More | The VMax® Kinetic ELISA Microplate Reader, the first of its kind for monitoring reactions over time, opened the door to enzyme assays and continues to be the workhorse of the laboratory environment. Based on a rugged, simple design, the VMax Absorbance Microplate Reader offers a mean time between The VMax® Kinetic ELISA Microplate Reader, the first of its kind for monitoring reactions over time, opened the door to enzyme assays and continues to be the workhorse of the laboratory environment. Based on a rugged, simple design, the VMax Absorbance Microplate Reader offers a mean time between failure (MTBF) of 20,000 hours with 97 independent and stationary fiber optics so that the microplate remains stationary during the entire reading cycle, reducing the number of moving parts that can wear and need replacement.
Through sequential, single-well illumination, 100% of the available light is directed to each well through the optical fibers to achieve linearity to higher optical densities (ODs) and optimal signal-to-noise ratios. At 5 seconds to read a 96-well endpoint assay or a 5 second minimum interval between kinetic reads, the VMax Microplate Reader has both speed and performance.
The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices.
VMax Microplate Readers can be operated as stand-alone instruments and are also supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software.
Features - Extend uptime with an estimated 20,000 hour mean time between failure
- Maximize assay signal-to-noise ratios through a unique optical system that directs all available light to each well
- Achieve higher throughput with a 5 second microplate read time
- Read up to 2 wavelengths in endpoint or kinetic absorbance for 96-well plates
- Mix samples in microplate wells by user-programmable Automix feature
- Operate without an attached computer using the onboard microprocessor
- Add assay flexibility with additional filters
... Read More |