The fume hood is an important piece of laboratory safety equipment designed to protect personnel and the environment from toxic fumes by drawing air from a contained area. The lining material of a fume hood confers its containment properties and polypropylene offers many advantages in this regard. Some of these include its impermeability, durability, and resistance to corrosion. For this reason, polypropylene fume hoods are recommended for most applications. When purchasing a polypropylene fume hood, some factors to consider include the size of the hood—most common sizes run from 3-8 feet, whether your lab has ducting capabilities or if a ductless model is needed, whether a constant volume or variable air volume exhaust system will be used, the material and operating speed of the blower, sash height, and the benchtop material. After purchase, fume hoods require regular maintenance and adherence to safety guidelines; always be sure to follow manufacturer instructions to ensure maximum safety.
| | | |
Company | NuAire | NuAire | NuAire |
Item | FumeGard NU-156 Vertical Laminar Airflow Fume Hood | FumeGard NU-162 Conventional Fume Hood | FumeGard NU-164 By-Pass Fume Hood |
Citations | | | |
Catalog Number | NU-156 | NU-162 | NU-164 |
Price | | | |
Exterior Dimensions | varies with model | varies with model | varies with model |
Interior Dimensions | varies with model | varies with model | varies with model |
Description | NuAire’s all Polypropylene Model NU-156/E FumeGard Vertical Laminar Flow Wet Process Fume Hood is a bench module Fume Hood which utilizes the latest state-of-the-art technologies in laminar airflow design, materials and manufacturing processes. The modular constructed Fume Hood can be used anywhere NuAire’s all Polypropylene Model NU-156/E FumeGard Vertical Laminar Flow Wet Process Fume Hood is a bench module Fume Hood which utilizes the latest state-of-the-art technologies in laminar airflow design, materials and manufacturing processes. The modular constructed Fume Hood can be used anywhere space permits where product (work-in-process) and personnel protection are required for chemical research, microelectronics, semi-conductor design/development and/or production assembly processes. Bench Fume Hoods consist of a single piece construction and can be placed on a customer bench or on a special option polypropylene base provided for the Fume Hood. A significant number of design innovations give the NuAire laminar flow equipment superior performance qualities in airflow, lighting, noise levels and vibration. In addition, NuAire’s “Narrow Line Design” technique achieves excellent appearance and ruggedness through the use of large modular components, reinforced construction techniques and contrasting color schemes.
The Model NU-156/E FumeGard Vertical Laminar Flow Clean Air Polypropylene Wet Process Fume Hood is a product resulting from the development of the “laminar” flow principle, the application of environmental controls in the fields of biological research or chemical containment and the necessity to provide a chemically inert and resistant work space. The wet process fume hood, when used with proper laboratory technique, is an effective laboratory aid in obtaining optimum control over product quality while reducing the potential for exposure of both product and personnel to airborne particulate chemical agents as well as fumes and vapors generated as a result of work-in-progress operations.
The NU-156/E FumeGard has been designed and tested to the performance criteria as established by the NSF/ANSI 49 for Biological Safety Cabinet. In addition, the NU-156/E meets or exceeds ISO 5 air quality conditions. The NU-156/E has been independently tested by Knutson Ventilation; Minneapolis, MN for its containment properties (i.e. personnel protection) to ASHRAE Standard 110-2016 for Fume Hoods, with a Performance Hood Rating of AM <0.1 (instrument’s limit of detection) when operating at a sash height of 10 inches (254mm).... Read More | The FumeGard NU-162 is built primarily of stress relieved polypropylene to which NuAire has added anti-oxidizing agents and UV stabilizers. This increases tensile strength and improves thermal characteristics. NU-162 has a single piece airfoil across the bottom of the work access opening. As the The FumeGard NU-162 is built primarily of stress relieved polypropylene to which NuAire has added anti-oxidizing agents and UV stabilizers. This increases tensile strength and improves thermal characteristics. NU-162 has a single piece airfoil across the bottom of the work access opening. As the sash is lowered, the face velocity increases rapidly. Fumes, gases, vapors, aerosols, and particulate are drawn through vents by an exterior exhaust duct. “Double wall” construction forms the plumbing chase for routing and connecting all services. This compartment is under negative pressure to minimize fume build-up.
NU-162 FumeGard has been independently tested to meet and exceed the requirements of ASHRAE Standard 110-1995 and is SEFA 1-1992 certified.
Available in polypropylene, PVC, CPVC, Flame Retardant Polypropylene, PVDF, HDPE or Teflon® construction.... Read More | Constructed of stress-relieved polypropylene, the FumeGard NU-164 has a by-pass (protected by a grill) which maintains a constant volume of airflow. As the sash is closed, air is by-passed at the top of the hood, causing the hood face velocity to increase much more slowly than a conventional fume Constructed of stress-relieved polypropylene, the FumeGard NU-164 has a by-pass (protected by a grill) which maintains a constant volume of airflow. As the sash is closed, air is by-passed at the top of the hood, causing the hood face velocity to increase much more slowly than a conventional fume hood. A deflector vane across the bottom of the opening directs airflow across the work surface. This provides a permanent opening even when the sash is closed. Most of the exhausted air enters the fume hood through the by-pass. The eye-level Control Center has on/off switches for exterior mounted fluorescent light or optional electrical devices (outlets, window alarms, night setback controls, or exhaust blower interlock systems).
The cabinet is designed to sit on existing casework or a NuAire polypropylene base. The NU-164 can be designed to meet your specific laboratory requirements.... Read More |
Quantity | EA | EA | EA |
Get Quote | | | |