Description | Our #850-NB “Nitrogen Dry Box” is a completely enclosed environmental chamber ideal for working in your preferred inert gas atmosphere.
Any inert gas such as Nitrogen, Argon, Helium and Plasma are easily maintained.
The unit is compact, lightweight, and portable. The design makes it easily Our #850-NB “Nitrogen Dry Box” is a completely enclosed environmental chamber ideal for working in your preferred inert gas atmosphere.
Any inert gas such as Nitrogen, Argon, Helium and Plasma are easily maintained.
The unit is compact, lightweight, and portable. The design makes it easily moveable from lab to lab.
Everything you need is included with the glove box. All you need to add is your gas of choice and your preferred research materials.
Features:
- Standard 24 month warranty (Not gloves or consumables).
- Formed one piece clear acrylic top section with rounded “Easy Clean” corners.
- Matched die molded white thermoset bottom with rounded “Easy Clean” corners.
- Two (2) vacuum diaphragm pumps. One each for the drying train and transfer chamber.
- The drying train includes three (3) clear acrylic canisters filled with Molecular Sieve™.
- Transfer chamber is 12” (305 mm) long x 11” (280 mm) I.D.
- All controls are illuminated.
- “Bright Light” system (40,000 hour lamp guarantee).
- White ambidextrous Hypalon™ gloves.
- All clamps are adjustable to compensate for wear.
- The front sloped viewing panel minimizes glare.
- Vacuum gauge on transfer chamber.
- Self sealing quick disconnects enable changing of the drying train canisters without disturbing the internal atmosphere.
- Four (4) ground key cock valves for purging.
- Transfer chamber leveling tray for handling liquids.
- Hospital grade multiple electric outlet (socket) strip. UL, CSA, and CE approved.
... Read More | The #855-AC (Anaerobic Chamber) has been designed for manually controlling your atmosphere when working with Oxygen sensitive materials. It is perfect for working in situations requiring low levels of Oxygen during critical isolation of the operator or your research materials. Any inert gas may be The #855-AC (Anaerobic Chamber) has been designed for manually controlling your atmosphere when working with Oxygen sensitive materials. It is perfect for working in situations requiring low levels of Oxygen during critical isolation of the operator or your research materials. Any inert gas may be used.
Its main advantage is minimizing the risk of Oxygen entry into the main working chamber. If trace amounts of Oxygen happen to enter the main chamber, the Catalyst Heater reduces it to water vapor. The drying train can then be activated to remove any excess water vapor.
The #855-AC is offered as a complete system ready to use. There are no other components required. All you need to add are your work samples and gas of choice.
The #855-ACB for multiple operators contains all the features of our single operator unit, but it has more capacity. It is ideal for two or more operators working together up to a maximum of four (4) people.
Features:
- Standard 24 month warranty. (Not gloves or consumables.)
- Formed one-piece clear plastic top section with “Easy Clean” corners.
- Matched die molded white thermoset bottom with “Easy Clean” corners.
- Two vacuum diaphragm pumps,one each for the drying train and the transfer chamber (purging),
- Drying train includes three (3) polycarbonate canisters filled with Molecular Sieve™.
- All controls are illuminated.
- “Bright Light” system. (40,000 hours guarantee.)
- White ambidextrous Hypalon™ gloves.
- All clamps are adjustable to compensate for wear.
- Adjustable vacuum gauge on transfer chamber.
- Four (4) ground key cock valves for purging.
- Transfer chamber is 12” (305 mm) long x 11” (280) I.D.
- Electrical outlet (socket) strip. (UL,CSA, & CE)
- Self sealing quick disconnects allow changing of the drying train without disturbing the internal atmosphere.
... Read More | This new Hypoxia Chamber Glove Box is ideal for tissue culture work, including tumor cell and stem cell research. It features a color operated “touch screen” for automatically controlling oxygen levels, temperature levels, and carbon dioxide levels.
Basic Features Include:This new Hypoxia Chamber Glove Box is ideal for tissue culture work, including tumor cell and stem cell research. It features a color operated “touch screen” for automatically controlling oxygen levels, temperature levels, and carbon dioxide levels.
Basic Features Include:
- 8” Color Panel Touch Screen
- Thermoelectric Assembly (Peltier device)
- O2 Sensor and CO2 sensor
- Password protected, configurable PID control
- Platinum RTD with sealing gland
- One touch, on screen data logging
- N2, CO2, and O2 gas hook-up
- Air circulation Fan
- Inert gas hook-up
- Configurable for up to six individually controlled
- Ethernet port connection for data logging sampling chambers.
... Read More | The 857-OTA One-Touch "Go Anaerobic" chamber allows one simple press of the "Go Anaerobic" button to create a strict anaerobic environment. No standing around to manually purge glove box. Simply push the "Go Anaerobic" button on the large, color, touch-screen display and the glove box automaticallyThe 857-OTA One-Touch "Go Anaerobic" chamber allows one simple press of the "Go Anaerobic" button to create a strict anaerobic environment. No standing around to manually purge glove box. Simply push the "Go Anaerobic" button on the large, color, touch-screen display and the glove box automatically begins the purging sequence. Only 300 liters of gas needed to achieve anaerobic atmosphere!
The 857-OTA Anaerobic Chamber includes automatic purging of main chamber and transfer chamber, oxygen analyzer, pressure hold function, and a large easy-to-use touch screen.
Features:
- Large, color, "Touch Screen" display
- "Go Anaerobic" automatic purging
- CE Approved electrical outlet strip.
- Three Drying Train canisters with quick dis-connects.
- White ambidextrous Hypalon gloves.
- Programmable Catalyst Heater Unit.
- Two ground key-cock valves on main chamber.
- "Bright Light" System. Two 1/4" NPT gas connections.
- Transfer chamber (12" long x 11" I.D.)
- Standard 24 month warranty.
... Read More | The NEW #890-THC accurately maintains temperature and humidity (Rh) inside a roomy single operator glove box. We also offer multiple operator units.
The unit is operated by merely touching the color control screen for the functions desired. It includes your private password protected administrator The NEW #890-THC accurately maintains temperature and humidity (Rh) inside a roomy single operator glove box. We also offer multiple operator units.
The unit is operated by merely touching the color control screen for the functions desired. It includes your private password protected administrator controls. Touch screen viewing of the data logging function is included as well as a ethernet port connection for data logging.
Automatic purging cycles can be programmed. The humidity range control accuracy is ± 2% Rh.
Temperature can be regulated in either “F” or “C” degrees and the Peltier style thermoelectric assembly is accurate to ± 2 degrees C. Temperature range is from 16 to 44 degrees C.
Features:
- Standard 24 month warranty. (Not gloves or consumables.)
- Inert gas hookup capability.White ambidextrous Hypalon gloves.
- Platinum RTD with sealing gland.
- Four (4) pre-set conditions.
- Ethernet port for external computer data logging & remote ccess.
- Room temperature and Rh read outs.
- Thermoelectric assembly (Peltier device)
- Nebulizer for the Rh system.
- The top section is one piece clear acrylic plastic for easy viewing. It features “Easy Clean” corners.
- Four (4) key cock valves for purging. Two (2) on the main chamber and two (2) on the transfer chamber.
- 8” (203 mm) Color panel touch screen. Date and time display.
- Humidity (Rh) transmitter with 8 feet of sensor cable.
- Password protected, configurable “PID” controlled.
- 24 hour one touch, on screen data logging.
- Transfer chamber is 11” (280 mm) I.D. x 12” (305 mm) long.
- ”Bright White” light system (40,000 hour guarantee.)
... Read More |