Biological safety cabinets (biosafety cabinets) come in several classes (I, II, and III) that offer varying levels of protection from hazardous or contagious materials. For all classes of biological safety cabinet, the air is HEPA (high efficiency particulate air)-filtered before being released as exhaust. A Class I biosafety cabinet is designed to protect the user and the environment, not the sample as negative pressure is used to pull outside air in across the workspace.
Class II biological safety cabinets are divided into four subtypes (A1, A2, B1, and B2) and have the additional feature of protecting the sample as the air supply is HEPA-filtered before passing over the workspace. The Class II subtypes differ in the amount of recirculated air within the cabinet.
Class III biosafety cabinets (also known as gloveboxes) provide maximum protection for work in biosafety level 4 containment labs. A class III biosafety cabinet is a hermetically-sealed glovebox with access through a dunk tank or double-door box that allows for decontamination.
| | | | | |
Company | NuAire | NuAire | NuAire | NuAire | NuAire |
Item | LabGard NU-813 Class I Containment Ventilated Enclosure (CVE) | Allergard™ ES NU-608 Class I Animal Refuse Workstation | LabGard® ES LP NU-640 Class II, Type A2 Animal Handling Biological Safety Cabinet | LabGard® ES NU-427 Class II, Type B1 Biosafety Cabinet | LabGard® ES NU-677 Class II, Type A2 Animal Handling Biosafety Cabinet |
Citations | | | | | |
Reviews | | | | | |
Catalog Number | NU-813 | NU-608 | NU-640 Series | NU-427 | NU-677 |
Price | | | | | |
Class/Type | Class I | Class I | Class II, Type A2 | Class II, Type B1 | Class II, Type A2 |
Air Inflow Rate | 80 fpm | Inquire | 0.53 m/s | 105 fpm (0.53 m/s) | 105 fpm (0.53 m/s) |
Size(s) | 3, 4, 6-foot (0.9, 1.2, 1.8-meter) | Inquire | Inquire | 4, 6-foot (1.2, 1.8-meter) | 4, 5, 6-foot (1.2, 1.5, 1.8-meter) |
Recirculated/Exhausted Air | 0% / 100% | 100% Exhausted | 70% Recirculated / 30% Exhausted | 30% / 70% | Inquire |
Exterior Dimensions | varies with model | varies by model | (WxDxH) 56.4 to 80.4 x 33 x 78.3 to 86.3 in. (1433 to 2042 x 838 x 1987 to 2190 mm) | varies with model | varies with model |
Interior Dimensions | varies with model | (WxDxH) 46.4 x 29.75 x 28.1 in (1178 x 715 x 715 mm) | (WxDxH) 46.5 to 70.5 x 22.7 x 24.6 in. (1181 to 1791 x 578 x 626 mm) | varies with model | varies with model |
Description | The LabGard Containment Cabinet NU-813 is offered as a Class I Containment Cabinet equipped with a HEPA filter. In the Class I configuration, the NU-813 provides personnel protection for handling low risk aerosols and particulate matter. Room air enters the Cabinet, flowing past the operator into The LabGard Containment Cabinet NU-813 is offered as a Class I Containment Cabinet equipped with a HEPA filter. In the Class I configuration, the NU-813 provides personnel protection for handling low risk aerosols and particulate matter. Room air enters the Cabinet, flowing past the operator into the work access opening providing an air barrier which minimizes contaminants generated within the cabinet work zone from migrating into the room. The air flows through the cabinet carrying contaminants with it, exiting through a HEPA filter as a Class I Cabinet.... Read More | Inquire | The LabGard® ES LP (Low Profile) NU-640 Class II, Type A2 Animal Handling Biosafety Cabinet provides the largest work access opening with the smallest footprint while offering enough versatility to assist with all facets in the vivarium industry. 105 fpm [0.53 m/s] in-flow combined with 60 fpm [ The LabGard® ES LP (Low Profile) NU-640 Class II, Type A2 Animal Handling Biosafety Cabinet provides the largest work access opening with the smallest footprint while offering enough versatility to assist with all facets in the vivarium industry. 105 fpm [0.53 m/s] in-flow combined with 60 fpm [0.30 m/s] true laminar down-flow creates the dynamic air barrier. The nominal 6 foot [1.8 m] wide cabinet allows the ability to mix and match an assortment of configurations. Combine Refuse Disposal with Dirty Cage Collection to create your perfect animal waste station. The NU-640 also fits through standard doorways. ... Read More | The LabGard ES (Energy Saving) NU-427 Class II, Type B1 Laminar Flow Biological Safety Cabinet (BSC) is a bench/table top model, utilizing an Energy Saver DC ECM motor optimally determined forward curved fan for each model size/width to maximize both energy efficiency and filter loading capacity. The LabGard ES (Energy Saving) NU-427 Class II, Type B1 Laminar Flow Biological Safety Cabinet (BSC) is a bench/table top model, utilizing an Energy Saver DC ECM motor optimally determined forward curved fan for each model size/width to maximize both energy efficiency and filter loading capacity. The Energy Saver ECM motor is controlled via a solid-state DC motor controller that provides automatic compensation (constant volume control) for both filter loading and line voltage variances. The NU-427 BSC is a product resulting from the development of the "laminar flow" principle and the application of environmental controls as required in the field of biological research or chemical containment. The NU-427 BSC when used with proper technique, is an effective laboratory aid in obtaining the optimum control over product quality while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents in low to moderate risk-hazard research and use of the BSC to work with chemicals and trace amounts of radio nuclides required as an adjunct to microbiological studies, as prescribed by the Center for Disease Control (CDC) Atlanta, Georgia.... Read More | The LabGard ES (Energy Saver) Model NU-677 Animal Handling Biosafety Cabinet (LFBSC) is a bench/table top model, with an integral castored support stand for operation as a console model. The LabGard model NU-677 utilizes an Energy Saver DC ECM motor optimally determined forward curved fan for each The LabGard ES (Energy Saver) Model NU-677 Animal Handling Biosafety Cabinet (LFBSC) is a bench/table top model, with an integral castored support stand for operation as a console model. The LabGard model NU-677 utilizes an Energy Saver DC ECM motor optimally determined forward curved fan for each model size/width to maximize both energy efficiency and filter loading capacity. The Energy Saver ECM motor is controlled via a solid-state DC motor controller that provides automatic compensation (constant volume control) for both filter loading and line voltage variances.
The Laminar Flow Biosafety Cabinet, (LFBSC) is a product resulting from the development of the ""laminar flow"" principle (see airflow schematic) and the application of environmental controls as required in the field of biological research or chemical containment. The LFBSC, when used with proper technique, is an effective laboratory aid in obtaining the optimum control over product quality while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents in low to moderate risk-hazard research and drug preparation or product operations, as prescribed by the Center for Disease Control (CDC) Atlanta, Georgia.
The NU-677 bench LFBSC is known as a Class II, Type A2 Biosafety Cabinet. This is possible since NuAire's cabinet conforms to the following requirements:
- Maintain a minimum average s inflow velocity of 100 ft/min (0.51 m/s) through the work access opening;
- Have HEPA/ULPA filtered downflow air that is a portion of the mixed downflow and inflow air from a common exhaust plenum;
- May exhaust HEPA/ULPA filtered air back into the laboratory or to the environment through an external exhaust system connected to the cabinet with a canopy connection; and
- Have all biologically contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums.
If working with volatile chemicals, the unit must be connected to an external exhaust system. Type A2 cabinets may be used for work with volatile chemicals if permitted by a chemical risk assessment.... Read More |
Get Quote | | | | | |