Biological safety cabinets (biosafety cabinets) come in several classes (I, II, and III) that offer varying levels of protection from hazardous or contagious materials. For all classes of biological safety cabinet, the air is HEPA (high efficiency particulate air)-filtered before being released as exhaust. A Class I biosafety cabinet is designed to protect the user and the environment, not the sample as negative pressure is used to pull outside air in across the workspace.
Class II biological safety cabinets are divided into four subtypes (A1, A2, B1, and B2) and have the additional feature of protecting the sample as the air supply is HEPA-filtered before passing over the workspace. The Class II subtypes differ in the amount of recirculated air within the cabinet.
Class III biosafety cabinets (also known as gloveboxes) provide maximum protection for work in biosafety level 4 containment labs. A class III biosafety cabinet is a hermetically-sealed glovebox with access through a dunk tank or double-door box that allows for decontamination.
| | | | | |
Company | NuAire | NuAire | NuAire | NuAire | NuAire |
Item | LabGard® ES LP NU-640 Class II, Type A2 Animal Handling Biological Safety Cabinet | Allergard™ ES NU-608 Class I Animal Refuse Workstation | LabGard TE (Total Exhaust) NU-560 Class II, Type B2 Biosafety Cabinet | LabGard® ES (Energy Saver) Class II Biosafety Cabinets | LabGard® ES TE NU-565 Class II, Type B2 Biosafety Fume Hood |
Citations | | | | | |
Catalog Number | NU-640 Series | NU-608 | NU-560 | LabGard | NU-565 |
Price | | | | | |
Class/Type | Class II, Type A2 | Class I | Class II, Type B2 | Class II, Type A2 | Class II, Type B2 |
Air Inflow Rate | 0.53 m/s | Inquire | 105 fpm (0.53 m/s) | 105 fpm (0.53 m/s) | 105 fpm (0.53 m/s) |
Size(s) | Inquire | Inquire | 4, 6-foot (1.2, 1.8-meter) | 3, 4, 5, 6-foot (0.9, 1.2, 1.5, 1.8-meter) | 4, 6-foot (1.2, 1.8-meter) |
Recirculated/Exhausted Air | 70% Recirculated / 30% Exhausted | 100% Exhausted | Inquire | 70% / 30% | Inquire |
Exterior Dimensions | (WxDxH) 56.4 to 80.4 x 33 x 78.3 to 86.3 in. (1433 to 2042 x 838 x 1987 to 2190 mm) | varies by model | varies with model | Varies with model | varies with model |
Interior Dimensions | (WxDxH) 46.5 to 70.5 x 22.7 x 24.6 in. (1181 to 1791 x 578 x 626 mm) | (WxDxH) 46.4 x 29.75 x 28.1 in (1178 x 715 x 715 mm) | varies with model | Varies with model | varies with model |
Description | The LabGard® ES LP (Low Profile) NU-640 Class II, Type A2 Animal Handling Biosafety Cabinet provides the largest work access opening with the smallest footprint while offering enough versatility to assist with all facets in the vivarium industry. 105 fpm [0.53 m/s] in-flow combined with 60 fpm [ The LabGard® ES LP (Low Profile) NU-640 Class II, Type A2 Animal Handling Biosafety Cabinet provides the largest work access opening with the smallest footprint while offering enough versatility to assist with all facets in the vivarium industry. 105 fpm [0.53 m/s] in-flow combined with 60 fpm [0.30 m/s] true laminar down-flow creates the dynamic air barrier. The nominal 6 foot [1.8 m] wide cabinet allows the ability to mix and match an assortment of configurations. Combine Refuse Disposal with Dirty Cage Collection to create your perfect animal waste station. The NU-640 also fits through standard doorways. ... Read More | Inquire | The LabGard ES (Energy Saver) Model NU-560 Laminar Flow Biosafety Cabinet (LFBSC) is a bench/table top model, optionally available with a base support stand, for operation as a console model. The LABGARD® ES model NU-560 utilizes an Energy Saver DC ECM motor optimally determined forward curved fan The LabGard ES (Energy Saver) Model NU-560 Laminar Flow Biosafety Cabinet (LFBSC) is a bench/table top model, optionally available with a base support stand, for operation as a console model. The LABGARD® ES model NU-560 utilizes an Energy Saver DC ECM motor optimally determined forward curved fan for each model size/width to maximize both energy efficiency and filter loading capacity. The Energy Saver ECM motor is controlled to airflow setpoints via a solid-state DC motor controller with digital dual thermistor airflow sensors that provide an automatic compensation (constant volume control) for both filter loading and line voltage variances.
The Laminar Flow Biosafety Cabinet, (LFBSC) is a product resulting from the development of the ""laminar flow"" principle and the application of environmental controls as required in the field of biological research or chemical containment. The LFBSC, when used with proper technique, is an effective laboratory aid in obtaining the optimum control over product quality while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents in low to moderate risk-hazard research and drug preparation or product operations, as prescribed by the Center for Disease Control (CDC) Atlanta, Georgia.
The NU-560 Bench LFBSC meets the requirements of a Class II, Type B2 since the cabinet conforms to the following requirements:
- Maintain a minimum average inflow velocity of 100 fpm (0.51m/s) through the work access opening;
- Have HEPA filtered downflow air drawn from the laboratory or the outside air (i.e. downflow air is not re-circulated from the cabinet exhaust air)
- Exhaust all inflow and downflow air to the atmosphere through a hard connection to the facility exhaust system after filtration through a HEPA filter without recirculation in the cabinet or return to the laboratory;
- Have all contaminated ducts and plenums under negative pressure or surrounded by directly exhausted (non-re-circulated through the work area) negative pressure ducts and plenums.
Type B2 cabinets may be used for work with nonflammable or explosive volatile chemicals and radionuclides required if permitted by chemical risk assessment.... Read More | NuAire Biological Safety Cabinets protect whats valuable providing personnel, product and/or environmental protection when looking to obtain optimum control over product quality while reducing the potential for exposure. Ergonomic Biosafety Cabinet design improves laboratory safety practices and NuAire Biological Safety Cabinets protect whats valuable providing personnel, product and/or environmental protection when looking to obtain optimum control over product quality while reducing the potential for exposure. Ergonomic Biosafety Cabinet design improves laboratory safety practices and process accuracy.
The LabGard® ES NU-540 Class II, Type A2 Laminar Flow Biological Safety Cabinet (LFBSC) is an effective primary engineering control in obtaining the optimum product quality, while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents in low to moderate risk-hazard research and drug preparation. The NU-540 offers economical operation through the use of an ultra high efficiency motor to maximize filter life and monolithic silicone-free construction for long product life.
The LabGard® Air NU-543 Class II, Type A2 Biological Safety Cabinet offers the very best in personnel, product, and environmental protection by monitoring and controlling real-time airflow through the use of an airflow sensor, and displays airflow speeds on the OLED interface. The ability to choose up to three different access opening heights allows our customers the option to select a larger access opening to improve technician movement and reach; select a smaller access opening to lower your total cost of ownership; or select somewhere in-between to get the best of both heights.... Read More | The LabGard ES (Energy Saver) Model NU-565 Laminar Flow Biosafety Fume Hood/Cabinet is a bench/table top model, optionally available with a base support stand, for operation as a console model. The LabGard model NU-565 utilizes an Energy Saver DC ECM motor optimally determined forward curved fan forThe LabGard ES (Energy Saver) Model NU-565 Laminar Flow Biosafety Fume Hood/Cabinet is a bench/table top model, optionally available with a base support stand, for operation as a console model. The LabGard model NU-565 utilizes an Energy Saver DC ECM motor optimally determined forward curved fan for each model size/width to maximize both energy efficiency and filter loading capacity. The Energy Saver ECM motor is controlled to airflow setpoints via a solid-state DC motor controller with digital dual thermistor airflow sensors that provide an automatic compensation (constant volume control) for both filter loading and line voltage variances.
The Laminar Flow Biosafety Fume Hood/Cabinet, is a product resulting from the development of the ""laminar flow"" principle and the application of environmental controls as required in the field of biological research or chemical containment. The Biosafety Fume Hood/Cabinet, when used with proper technique, is an effective laboratory aid in obtaining the optimum control over product quality while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents in low to moderate risk-hazard research and drug preparation or product operations, as prescribed by the Center for Disease Control (CDC) Atlanta, Georgia.
The NU-565 Bench meets the requirements of a Class II, Type B2 since the cabinet conforms to the following requirements:
- Maintain a minimum average inflow velocity of 100 fpm (0.51m/s) through the work access opening;
- Have HEPA filtered downflow air drawn from the laboratory or the outside air (i.e. downflow air is not re-circulated from the cabinet exhaust air)
- Exhaust all inflow and downflow air to the atmosphere through a hard connection to the facility exhaust system after filtration through a HEPA filter without recirculation in the cabinet or return to the laboratory;
- Have all contaminated ducts and plenums under negative pressure or surrounded by directly exhausted (non-re-circulated through the work area) negative pressure ducts and plenums.
Type B2 Biosafety Fume Hood/Cabinet classified to UL 1805 may be used for work with flammable or volatile chemicals and radionuclides required if permitted by chemical risk assessment.... Read More |