A cell culture incubator is designed to maintain a constant temperature and high humidity for the growth of tissue culture cells under a CO2 atmosphere. Typical temperature settings range from 4C to 50C, and CO2 concentrations run from 0.3 to 19.9%. Non-corrosive stainless steel interiors are standard, but some newer models feature antimicrobial copper surfaces to prevent contamination. Auto decontamination using heat or UV light is another new and attractive feature available in CO2 incubators.
Temperature in a CO2 incubator is typically controlled either by a water bath that circulates through the walls of the cabinet (
water jacketed CO2 incubator), or by electric coils that give off radiant heat. Some units also include refrigeration for cooling. Relative humidity is maintained between 95% and 98% by an atomizer system or water reservoir. Features of cell culture incubators such as programmable controls with password protection, temperature alarms, CO2 alarms, and door opening alarms enhance convenience and security for the user.
Find, compare, and request a quote for CO2 incubators and cell culture incubators across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
| | | | | |
Company | NuAire | NuAire | NuAire | NuAire | NuAire |
Item | In-VitroCell ES Zirconia Oxygen Control CO2 Incubators | In-VitroCell ES Direct Heat CO2 Incubator with Dual Sterilization Cycles and Humidity Control | In-VitroCell ES Direct Heat CO2 Incubator with Dual Sterilization Cycles | In-VitroCell ES Dual Sterilization CO2 Incubators | In-VitroCell ES Microbiological CO2 Incubators |
Citations | | | | | |
Catalog Number | NU-5831 | NU-5720 | NU-5710 | NU-5810 | NU-5800 Family |
Price | | | | | |
Temperature Range | 5°C to 55°C | 5°C to 55°C | 5°C to 55°C | 5C to 55C | 5°C to 55°C |
Volume | 7 ft³ or 200 L | 5 ft³ or 160 L | 5 ft³ or 160 L | 7.06 Ft3 or 200 L | 7 ft3 or 200 L |
Interior Dimensions | (W×D×H) 21 x 20 x 28 ½ in (540 x 509 x 724 mm) | (WxDxH) 20.25 x 20.678 x 24 in (514 x 525 x 610 mm) | (WxDxH) 20.25 x 20.678 x 24 in (514 x 525 x 610 mm) | (WxDxH) 21 x 20 x 28.5 in | Varies with model |
Exterior Dimensions | (W×D×H) 26½ x 27 x 40 in (673 x 691 x 1008 mm) | (WxDxH) 25.5 x 27.5 x 36.188 in (648 x 699 x 894 mm) | (WxDxH) 25.5 x 27.5 x 36.188 in (648 x 699 x 894 mm) | (WxDxH) 26.5 x 27 x 40 in | Varies with model |
CO2 Measurement | Dual Wave IR | Dual Wave IR | Dual Wave IR | Dual Wave IR | Dual Wave IR |
CO2 Range | 0.1 to 20% (0.0 Set Point Idles System) | 0.1 to 20% (0.0 Set Point Idles System) | 0.1 to 20% (0.0 Set Point Idles System) | 0.1 to 20% (0.0 set point idles system) | 0.1 to 20% (0.0 Set Point Idles System) |
Description | The NuAire NU-5831 In-VitroCell ES (Energy Saver) Direct Heat Hypoxic CO2 Incubator is designed to provide a reliable, controlled in-vitro environment suitable for growing tissue cell cultures as well as storing and preserving embryos, gametes and animal tissue cell cultures. This unit features a The NuAire NU-5831 In-VitroCell ES (Energy Saver) Direct Heat Hypoxic CO2 Incubator is designed to provide a reliable, controlled in-vitro environment suitable for growing tissue cell cultures as well as storing and preserving embryos, gametes and animal tissue cell cultures. This unit features a dual sterilizing system with a 95°C humidified decontamination cycle and a 145°C dry sterilizing cycle, a microprocessor-based dual wave infrared (IR) sensor for controlling the CO2 levels and a Zirconia ceramic O2 fuel cell sensor to keep oxygen levels between 0.5% and 21%. We offer a number of optional features including CuVerro® antimicrobial copper surfacing for killing bacteria within the chamber.
Features - NuTouch Electronic Control System
- 100% Stainless Steel Coved Interior Chamber
- Dual Temperature Sensor Probes
- Infrared (IR) CO2 Sensor
- Dual Sterilziation Cycles (NU-5810, 5820, 5830, 5840)
- Humidity Control System (NU-5820, 5840)
- O2 Control System (NU-5830, 5840)
- Four (4) Stainless Steel Shelves
- Eight (8) Stainless Steel Shelf Guides
- Four (4) Wall Brackets
- Field Reversible Outter Door
- Remote Alarm Output Contacts
- 4 to 20 mA Analog Output RS-485 Communication USB Port
- CO2 Sample Port
- Adjustable Leg Levelers
- Access Port and Plug with Breather Holes
- One (1) Water Pan
- One (1) 6.5 ft. / 2 m Electrical Cord
... Read More | The In-VitroCell™ ES Model NU-5720 is a direct heat 6.65ft3 (160 L) capacity CO2 Incubator featuring humidity monitoring and control using a sensor and 3-liter reservoir to inject water vapor to meet setpoint. Model NU-5720 provides optimal growth conditions for mammalian cells sensitive to humidityThe In-VitroCell™ ES Model NU-5720 is a direct heat 6.65ft3 (160 L) capacity CO2 Incubator featuring humidity monitoring and control using a sensor and 3-liter reservoir to inject water vapor to meet setpoint. Model NU-5720 provides optimal growth conditions for mammalian cells sensitive to humidity fluctuations.... Read More | The NuAire NU-5710 is a CO2 incubator that utilizes heating elements that surround the growth chamber on five sides. An independent door heater helps maintain temperature uniformity and reduce condensation. This direct heat model offers optimal cell growth conditions by producing humidity levels up The NuAire NU-5710 is a CO2 incubator that utilizes heating elements that surround the growth chamber on five sides. An independent door heater helps maintain temperature uniformity and reduce condensation. This direct heat model offers optimal cell growth conditions by producing humidity levels up to 95% and precisely controlling CO2 gas and temperature levels while minimizing potential contamination.... Read More | NuAire’s In-VitroCell ES (Energy Saver) NU-5810 Direct Heat (Air Jacketed) Microbiological CO2 Incubator features a 145°C dry sterilization cycle and 95°C humidified decontamination cycle as an added defensive against incubator contamination providing an optimal controlled environment for cell NuAire’s In-VitroCell ES (Energy Saver) NU-5810 Direct Heat (Air Jacketed) Microbiological CO2 Incubator features a 145°C dry sterilization cycle and 95°C humidified decontamination cycle as an added defensive against incubator contamination providing an optimal controlled environment for cell growth. In-VitroCell ES CO2 Incubators provide a stable in-vivo growth model with heating elements located on all 6 sides of the chamber. High density R5 insulation stabilizes the interior chamber temperature requiring less energy to maintain. Unique features such as dual sterilization cycle, humidity and hypoxia control ensure your research needs are met.The basic functionality to promote tissue cell growth by controlling Temperature and CO2 gas levels in the growth chamber. A relative humidity of 90% is produce through convention by a water pan. The Closed Loop HEPA Filtration System creates ISO Class 5 Clean-room like conditions to minimize potential contamination entering the growth chamber.
Features - NuTouch Intelligent Interface
- Constant Contamination Control (C3)
- Closed Loop HEPA Filtration
- ISO Class 5 Cleanroom Conditions
- Single Beam, Dual Wave Infrared (IR) Sensor
- Temperature Uniformity
- Incubator Humidity
- Advanced Construction
- Minimal Vibration Promotes Cell Growth
- Smaller Footprint with More Useable Space
- CuVerro® Antimicrobial Copper Surfaces
... Read More | NuAire Direct Heat (Air Jacketed) CO2 Incubators provide a stable in-vivo growth model with heating elements located on all 6 sides of the chamber. High density R5 insulation stabilizes the interior chamber temperature requiring less energy to maintain.
Unique features such as dual sterilization NuAire Direct Heat (Air Jacketed) CO2 Incubators provide a stable in-vivo growth model with heating elements located on all 6 sides of the chamber. High density R5 insulation stabilizes the interior chamber temperature requiring less energy to maintain.
Unique features such as dual sterilization cycle, humidity and hypoxia control ensure your research needs are met.... Read More |