Water Jacketed Incubator

Water Jacketed incubators are used in the lab setting to maintain temperatures for controlling biological samples or organisms. It works by using water regulate the temperature inside of the incubator. These incubators are comprised of two chambers: The inner chamber where the samples are placed and the outer chamber which contains the heated water. The water temperature is controllable and heats the inner chamber through the walls of the incubator. Water jacketed incubators are commonly used in research laboratories, especially in fields like microbiology, cell biology, chemistry, and genetics.
CompanyNuAireNuAireNuAireNuAire
ItemIn-VitroCell ES NU-8600 Water Jacketed CO2 IncubatorIn-VitroCell CO2 IncubatorsIn-VitroCell ES NU-8600 Water Jacketed CO2 IncubatorIn-VitroCell ES NU-8631 Hypoxic Water Jacketed CO2 Incubator with O2 Control
Citations
(1)
Catalog NumberNU-8600 FamilyCO2 IncubatorNU-8600NU-8631
Price
Volume5.65 ft3188 or 200 L160 L (5.7 cu. ft.)160 L (5.7 cu. ft.)
Temperature RangeInquire5 °C to 55°C
145 °C (Dry) or 95 °C (Humidified) Sterilization Cycles
5°C to 55°C5°C above ambient (to a 30°C max ambient) to 55°C
CO2 MeasurementInquireDual Wave IRDual Wave IRDual Wave IR
CO2 RangeInquire0% to 20%0.1 to 20%, 5% default set point0.1 to 20%, 5% default set point
DescriptionThe InVitroCell™ ES (Energy Saver) model NU-8600 is a CO2 Incubator that uses heated water that surrounds the growth chamber to created uniform temperature conditions for cell culture growth. Water Jacket model NU-8600 also uses an IR sensor to maintain proper CO2 gas levels and produces a ... Read MoreNuAire Laboratory CO2 Incubators deliver a higher level of performance for a dependable and reliable controlled in-vitro environment for optimum tissue cell culture growth. The chamber also provides an environment for the storage and preservation of gametes and animal tissue cell cultures at near ... Read MoreIn-VitroCell CO2 model NU-8600 uses a jacket of water that surrounds the growth chamber to maintain setpoint temperature consistently. Carbon dioxide gas is monitored through an IR (infrared) sensor. Temperature is monitored through the use of two temperature probes. The NuTouch electronic ... Read MoreIn-VitroCell CO2 model NU-8631 creates optimal hypoxic growth conditions by controlling oxygen levels through a sensor and automatically injecting Nitrogen gas to meet setpoint. Chamber temperature is established through the use of a water jacket to create uniform temperature throughout the chamber.... Read More
Get Quote