Autoclave Sterilizer / Laboratory Autoclaves

Laboratory autoclaves sterilize laboratory equipment by using high temperatures and pressure to produce steam. Autoclaves are found in research labs, medical environments, dental offices, and anywhere else where microbial contamination is a primary concern. When loading an autoclave, it is important the instruments not be touching each other so the steam can access every surface point. Some things to consider when purchasing an autoclave sterilizer are how much equipment the machine can hold, the temperature and pressure range, and if cooling is an option.
CompanyAmerex Instruments, Inc.Amerex Instruments, Inc.Amerex Instruments, Inc.Amerex Instruments, Inc.Amerex Instruments, Inc.
ItemHVP-50 Top-Loading 50L Autoclave (Fully Automatic Drying)HG-50 Top-Loading 50L Autoclaves (Without Drying)HV Series Portable Top-Loading AutoclavesHVA-110 Economical Top-Loading 110L Autoclave with Built-In Cooling Fan (Without Drying)HVA-85 Economical Top-Loading 85L Autoclave with Built-In Cooling Fan (Without Drying)
Citations
(1)
Reviews
Catalog NumberHVP-50HG-50HV-25 / HV-50 / HV-85 / HV-110HVA-110HVA-85
Price
Temperature Range105C to 135C105C to 135CHV-25: 105 to 126°C
HV-50: 105 to 135°C
105C to 135C105C to 135C
Interior Dimensions(Diam x H) 11.8 x 28 in(Diam x H) 14.3 x 18.2 inInquire(Diam x H) 16.5 x 31.3 in(Diam x H) 16.5 x 24.2 in
Exterior Dimensions(WxDxH) 20.1 x 24.8 x 40.9 in(WxDxH) 19.7 x 27.2 x 35.0 inInquire(WxDxH) 26 x 25.6 x 46.4 in(WxDxH) 26 x 25.6 x 39.4 in
Chamber Volume50 L50 L (Working Volume), 60 L (Actual Volume)Inquire110 L85 L
Pressure Range3 to 30 psi ( gauge)InquireHV-25 / HV-50: 3 to 22 PSI gauge (0.02 to 0.148 MPa)
HV-85 / HV-110: 3 to 30 PSI (0.02 to 0.206 MPa)
0 to 0.26 MPa0 to 0.26 MPa
DescriptionSpace-saving design with lid opening upward.

Fully automatic drying cycle for solid loads uses heat and vacuum for faster and more efficient drying.

Lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or when the temperature exceeds 97°C.

Vacuum pump
... Read More
Automatic lid opening button replaces a foot pedal.

Automatic lid closing button closes and locks lid conveniently and safely.

New body design with a 50- or 80-liter chamber of larger diameter and shorter height.

Safety interlock senses pressure and temperature and prevents lid from opening
... Read More
The 25-liter (HV-25), 50-liter (HV-50), 85-liter (HV-85), and 110 liter (HV-110) Autoclaves are self-contained, portable floor models mounted on caster wheels. They occupy minimum floor space and can fit conveniently into many locations in the laboratory. Their many uses include the sterilization of... Read MoreSpace-saving design with lid opening upward.

Standard built-in cooling fan for faster post- sterilization cooling.

Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.

Agar sterilization mode sterilizes agar, and
... Read More
Space-saving design with lid opening upward.

Standard built-in cooling fan for faster post- sterilization cooling.

Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.

Agar sterilization mode sterilizes agar, and
... Read More
Get Quote