Laboratory autoclaves sterilize laboratory equipment by using high temperatures and pressure to produce steam. Autoclaves are found in research labs, medical environments, dental offices, and anywhere else where microbial contamination is a primary concern. When loading an autoclave, it is important the instruments not be touching each other so the steam can access every surface point. Some things to consider when purchasing an autoclave sterilizer are how much equipment the machine can hold, the temperature and pressure range, and if cooling is an option.
| | | | | |
Company | Amerex Instruments, Inc. | Amerex Instruments, Inc. | Amerex Instruments, Inc. | Amerex Instruments, Inc. | Amerex Instruments, Inc. |
Item | HV-50 Top-Loading 50L Autoclave (Without Drying) | HA-300MD Top-Loading 50L Autoclave (Manual Drying) | HRH-110 Front-Loading 110L (Fully Automatic Drying) | HVA-110 Economical Top-Loading 110L Autoclave with Built-In Cooling Fan (Without Drying) | HVA-85 Economical Top-Loading 85L Autoclave with Built-In Cooling Fan (Without Drying) |
Citations | | | | | |
Reviews | | | | | |
Catalog Number | HV-50 | HA-300MD | HRH-110 | HVA-110 | HVA-85 |
Price | | | | | |
Temperature Range | 105C to 135C | 105C to 126C | 105C to 135C (Programmable) | 105C to 135C | 105C to 135C |
Interior Dimensions | (Diam x H) 11.8 x 28 in | (Diam x H) 11.8 x 26.4 in | (Diam x D) 16.5 x 31.3 in | (Diam x H) 16.5 x 31.3 in | (Diam x H) 16.5 x 24.2 in |
Exterior Dimensions | (WxDxH) 20 x 21 x 41 in | (WxDxH) 17.3 x 20.5 x 42.1 in | (WxDxH) 27.2 x 45.3 x 54.5 in | (WxDxH) 26 x 25.6 x 46.4 in | (WxDxH) 26 x 25.6 x 39.4 in |
Chamber Volume | 50 L | 50 L | 110 L | 110 L | 85 L |
Pressure Range | 3 to 22 psi | 3 to 30 psi (gauge) (0.021 to 0.21 MPa) | Inquire | 0 to 0.26 MPa | 0 to 0.26 MPa |
Description | Space-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurizationSpace-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
One-touch lever to easily open and close chamber lid. Programmable rate of steam exhaust.
Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.
In-process display shows status and progress of sterilization cycle.
Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
Unique accessory: Floating sensor to monitor load temperature.
Sterilization timer is activated only when load temperature reaches set temperature.
Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up
Memory backup system retains user-programmed parameters even in case of power failure.... Read More | Top loading design is ideal for the sterilization of media and other liquids in tall flasks and bottles.
Deep chamber for accommodating fermentors and bioreactors.
Space-saving, stand-alone unit occupies minimal floor space and can fit conveniently into many locations in the laboratory.
Top loading design is ideal for the sterilization of media and other liquids in tall flasks and bottles.
Deep chamber for accommodating fermentors and bioreactors.
Space-saving, stand-alone unit occupies minimal floor space and can fit conveniently into many locations in the laboratory.
Full-count sterilization guarantees sterilization at the preset temperature and time. Timer pauses if chamber temperature falls 1ºC below the preset temperature.
Liquid cycles with slow exhaust or natural cooling for liquids and solids without drying.
Drying cycle for glassware and other solid loads.
Additional drying cycle without re-sterilization.
Micro-processor controlled for precise sterilization.
Internal steam generator uses purified water to generate pure steam.
Audio/visual alarms and on-board diagnostics for rapid repair.... Read More | Front-loading design
Fully automatic operation from start to finish with or without drying.
One-touch door closing lever opens and closes the door easily, surely and safely.
Pre-vacuum cycle - vacuum pump removes air from the chamber when sterilizing solids such as glassware and pipette tips, Front-loading design
Fully automatic operation from start to finish with or without drying.
One-touch door closing lever opens and closes the door easily, surely and safely.
Pre-vacuum cycle - vacuum pump removes air from the chamber when sterilizing solids such as glassware and pipette tips, thereby eliminating cold spots, and ensuring faster and more efficient sterilization.
Drying by heat and vacuum increases drying efficiency and reduces cycle times.
Additional drying mode for complete drying without having to run the sterilization cycle again.
Bacteria filter reduces re-contamination.
Lid safety interlock prevents lid from opening during a cycle, when the chamber is pressurized, or when the chamber temperature is above 97°C at which super-heated liquids might boil over when disturbed.
Door-closure sensor prevents a cycle from starting unless the door is properly closed.
Process display shows the program selected and the status of the sterilization cycle.
Chamber dimensions: 16.5” Diameter x 31.3” Depth
Chamber volume: 110 liters... Read More | Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying.
One-touch lever to easily open and close chamber lid.
Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up.
Door-closure sensor prevents a cycle from starting unless the door is closed properly.
In-process display shows the status and the progress of sterilization cycle.... Read More | Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying.
One-touch lever to easily open and close chamber lid.
Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up.
Door-closure sensor prevents a cycle from starting unless the door is closed properly.
In-process display shows the status and the progress of sterilization cycle.... Read More |