Autoclave Sterilizer / Laboratory Autoclaves

Laboratory autoclaves sterilize laboratory equipment by using high temperatures and pressure to produce steam. Autoclaves are found in research labs, medical environments, dental offices, and anywhere else where microbial contamination is a primary concern. When loading an autoclave, it is important the instruments not be touching each other so the steam can access every surface point. Some things to consider when purchasing an autoclave sterilizer are how much equipment the machine can hold, the temperature and pressure range, and if cooling is an option.
CompanyAmerex Instruments, Inc.Amerex Instruments, Inc.Amerex Instruments, Inc.Amerex Instruments, Inc.Amerex Instruments, Inc.
ItemHVA-110 Economical Top-Loading 110L Autoclave with Built-In Cooling Fan (Without Drying)HA-300MW Top-Loading 50L Autoclave (Without Drying)HV-85 Top-Loading 85L Autoclave (Without Drying)HVA-85 Economical Top-Loading 85L Autoclave with Built-In Cooling Fan (Without Drying)HVE-50 Economical Top-Loading 50L Autoclave (Without Drying)
Citations
(2)
Reviews
Catalog NumberHVA-110HA-300MWHV-85HVA-85HVE-50
Price
Temperature Range105C to 135C105C to 126C105C to 135C105C to 135C105C to 135C
Interior Dimensions(Diam x H) 16.5 x 31.3 in(Diam x H) 11.8 x 26.4 in(Diam x H) 16.5 x 24.2 in(Diam x H) 16.5 x 24.2 in(Diam x H) 11.8 x 28 in
Exterior Dimensions(WxDxH) 26 x 25.6 x 46.4 in(WxDxH) 17 x 21 x 42 in(WxDxH) 26 x 25.6 x 39.4 in(WxDxH) 26 x 25.6 x 39.4 in(WxDxH) 20.1 x 20.8 x 40.9 in
Chamber Volume110 L50 L85 L85 L50 L
Pressure Range0 to 0.26 MPa3 to 22 psi (gauge)3 to 30 psi0 to 0.26 MPa3 to 30 psi (gauge) (0.021 to 0.21 MPa)
DescriptionSpace-saving design with lid opening upward.

Standard built-in cooling fan for faster post- sterilization cooling.

Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.

Agar sterilization mode sterilizes agar, and
... Read More
Top loading design is ideal for the sterilization of media and other liquids in tall flasks and bottles.

Deep chamber for accommodating fermentors and bioreactors.

Space-saving, stand-alone unit occupies minimal floor space and can fit conveniently into many locations in the laboratory.

... Read More
Space-saving design with lid opening upward.

Programmable auto-start for initiating a cycle up to 1 week later.

Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.

Automatic air purging by a microprocessor prevents over-pressurization
... Read More
Space-saving design with lid opening upward.

Standard built-in cooling fan for faster post- sterilization cooling.

Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.

Agar sterilization mode sterilizes agar, and
... Read More
Space-saving design with lid opening upward.

Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.

Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.

Agar melting mode for melting
... Read More