Thermogravimetric analyzers measure changes in mass or weight in response to increases in temperature or time. These kinds of measurements can give valuable information about a material's thermal stability, response to oxidation, composition, decomposition kinetics, moisture content, and more. Thermogravimetric analyzers thus have applications for many types of studies such as materials science research, studies of reaction kinetics, and determining the durability of materials used to make space craft.
Some things to consider when purchasing a thermogravimetric analyzer include the type of samples the machine is optimized for, sample weight, temperature range, ease of calibration, and analysis and cool down times.
Find, compare, and request a quote for thermogravimetric analyzers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
| | |
Company | Shimadzu | Shimadzu |
Item | TGA-51/51H Thermogravimetric Analyzers (Macro) | TGA-50/50H Thermogravimetric Analyzers (Micro) |
Citations | | |
Catalog Number | TGA-51/51H | TGA-50/50H |
Price | | |
Temperature Range | up to 1000C (TGA-51); up to 1500C (TGA-51H) | up to 1000C (TGA-50); up to 1500C (TGA-50H) |
Balance Type | Inquire | Inquire |
Weight Range | +/-20mg, +/-200mg, +/- 2000mg | +/-20mg, +/-200mg |
Weight Resolution | 0.001 mg | 0.001 mg |
Description | The TGA-50 series is equipped with a lightweight balance mechanism and taut band fulcrum. These have outstanding vibration resistance and provide for stable high sensitivity measurements. These instruments have an extremely wide applicability range, from measuring large-volume samples that cannot be The TGA-50 series is equipped with a lightweight balance mechanism and taut band fulcrum. These have outstanding vibration resistance and provide for stable high sensitivity measurements. These instruments have an extremely wide applicability range, from measuring large-volume samples that cannot be measured using TG/DTA systems, or allowing the use of a variety of sample cell sizes.
Features:
- Precise Measurements to 1 µg
- Efficient Evolved Gas Analysis
- Increased Functionality: The TGA-51/51H Analyzes Up To 10 Grams of Sample While Maintaining Precision in the µg Range
- A wide selection of gas atmosphere from air, inert gas, reactive gas including hydrogen to vacuum
- Extensive Selection of Sample Crucibles
Specifications
Temperature Range: Ambient to 1000C (TGA-51), Ambient to 1500C (TGA-51H)
Weight Measuring Range: +/-20mg, +/-200mg, +/- 2000mg
Readability: 0.001mg
Sample Mass: 10g including tare
Programmable Heating Rate: 0.1C/hour to 99.9C/min (TGA-51), 0.1C/hour to 50.0C/min (TGA-51H)
Hold Time: 0 to 999min, 0 to 999 hour
Temperature program format: 99 steps maximum
Temperature program file: up to 100 files
Cooling Method: Air-cooled
Signal Output: Analog and digital
Atmosphere Control: Air, inert gas, reactive gas or vacuum. Built-in gas flowmeter (250ml/min maximum)
... Read More | The TGA-50 series is equipped with a lightweight balance mechanism and taut band fulcrum. These have outstanding vibration resistance and provide for stable high sensitivity measurements. These instruments have an extremely wide applicability range, from measuring large-volume samples that cannot be The TGA-50 series is equipped with a lightweight balance mechanism and taut band fulcrum. These have outstanding vibration resistance and provide for stable high sensitivity measurements. These instruments have an extremely wide applicability range, from measuring large-volume samples that cannot be measured using TG/DTA systems, or allowing the use of a variety of sample cell sizes.
Features:
- Precise Measurements to 1 µg
- Efficient Evolved Gas Analysis
- A wide selection of gas atmosphere from air, inert gas, reactive gas including hydrogen to vacuum
- Extensive Selection of Sample Crucibles
Specifications
Temperature Range: Ambient to 1000C (TGA-50), Ambient to 1500C (TGA-50H)
Weight Measuring Range: +/-20mg, +/-200mg
Readability: 0.001mg
Sample Mass: 1g including tare
Programmable Heating Rate: 0.1C/hour to 99.9C/min (TGA-50), 0.1C/hour to 50.0C/min (TGA-50H)
Hold Time: 0 to 999min, 0 to 999 hour
Temperature program format: 99 steps maximum
Temperature program file: up to 100 files
Cooling Method: Air-cooled
Signal Output: Analog and digital
Atmosphere Control: Air, inert gas, reactive gas or vacuum. Built-in gas flowmeter (250ml/min maximum)
... Read More |
Quantity | EA | EA |
Get Quote | | |