Description | Time to rethink protein analysis
More than 50 years ago, in 1964, the rapid N saw the light of day for the first time! Based on these experiences the newly developed rapid N exceed is the most economic and innovative nitrogen/protein analyzer according to Dumas. In day-to-day business it performs Time to rethink protein analysis
More than 50 years ago, in 1964, the rapid N saw the light of day for the first time! Based on these experiences the newly developed rapid N exceed is the most economic and innovative nitrogen/protein analyzer according to Dumas. In day-to-day business it performs routine analyses of food or feed up to 1 g sample weight in your laboratory. The rapid N exceed represents the fast, safe and environmentally friendly alternative to the classical Kjeldahl method.
As the most innovative enterprise in the field of elemental analysis, Elementar takes this traditional analytical technology to a new level. This is made possible by a completely new method of reduction of nitric oxides and absorption of excess oxygen in the analysis gas. Due to a defined interaction of reduction and oxidation (patent applied for) used reduction agent will be automatically generated during operation. Thus, a reduction reactor (reductor) can be used for several thousand samples without change or maintenance.
At the same time, Elementar relies on proven technology for the newly developed rapid N exceed:
- CO2 as carrier gas saves the finite resource helium and guarantees stable prices and constant availability
-
• The fastest protein analysis with analysis times of less than four minutes and highest sample throughput in this instrument class
-
• The post-combustion guarantees exact results, independent of any sample matrix
-
• The rapid N exceed never takes a break: it operates 24/7 – 365 days a year
... Read More | MAXimum performance in protein analysis
Elementar’s rapid MAX N exceed is the first Dumas method N/protein analyzer that utilizes the highly successful EAS REGAINER® technology for larger sample weights.
Drawing on Elementar’s decades of expertise, the instrument offers increased laboratory MAXimum performance in protein analysis
Elementar’s rapid MAX N exceed is the first Dumas method N/protein analyzer that utilizes the highly successful EAS REGAINER® technology for larger sample weights.
Drawing on Elementar’s decades of expertise, the instrument offers increased laboratory efficiency at a significantly lower price per sample. The rapid MAX N exceed stands for outstanding precision, sensitivity and sample flexibility, while its 24/7 unattended operation addresses the challenges faced by any high-throughput laboratory dealing with a wide range of sample types and weights.
Its use of the crucible technique makes it a low-maintenance instrument, while inputting sample weights up to 5g reduce the homogenization process.
Ease of use
The unique post-combustion technology ensures the complete digestion of even the most challenging species, omitting the need for grinding or milling without affecting reliable data quality. This helps you save valuable time in sample preparation.
Highest sample throughput
The rapid MAX N exceed offers N/protein determination in just five minutes, while the 90-position autosampler makes it possible to measure 300 samples per day. By utilizing EAS REGAINER® technology, users can run more than 1,000 samples without the need to exchange the reducing agent, meaning customers can enjoy outstanding low-maintenance intervention for industry-leading system uptime.
Sample flexibility
The upright crucible design ensures optimal combustion of any kind of liquid samples, including milk, beer, soft drinks, juice and soy sauce, while solid samples of 1g can be measured with outstanding precision and accuracy. The inclusion of unique post-combustion technology allows reliable, efficient and matrix-independent data collection to be achieved.
Future-proof investment
A 10-year warranty on the analyzer’s furnace and thermoconductivity detector (TCD) showcases its outstanding robustness and longevity, while our commitment to providing spare parts for a decade highlights our well-known long-term dedication to technical support. This combination results in an outstanding low cost of ownership and gives customers confidence in their return on investment.... Read More | UNICUBE® Micro combustion analysis has never been easier. Making 'good' even better: as a leader in elemental analysis technology, our products benefit from having more than 120 years of experience behind them. Now, we have used our technical know-how to take our proven micro elemental analyzer, theUNICUBE® Micro combustion analysis has never been easier. Making 'good' even better: as a leader in elemental analysis technology, our products benefit from having more than 120 years of experience behind them. Now, we have used our technical know-how to take our proven micro elemental analyzer, the vario MICRO cube, to the next level - always focusing on the needs of the users.
The result is the new UNICUBE, a cutting-edge tool for the elemental analysis of carbon, hydrogen, nitrogen, and sulfur. UNICUBE combines the low costs and the sensitivity of a micro elemental analyzer with the flexibility and outstanding robustness of a macro analyzer, providing unparalleled flexibility.
- One micro elemental analyzer for all tasks: 0.1 mg of pharmaceuticals can be analyzed just as precisely as up to 1 g of inhomogeneous soil samples, while volatile gasoline or temperature-proof silicon carbide can be analyzed just like coal, foodstuffs, or sewage sludge. UNICUBE makes this possible without any restriction of the elements, allowing simultaneous analysis for CHNS - or for the combinations CNS, CHN, CN, O, and Cl - in one sample run.
- High-performance micro elemental analysis for the sharpest peaks: UNICUBE utilizes Elementar's proprietary and improved direct TPD (Temperature Programmed Desorption) technology for optimized reliability and performance in gas separation. Working in combination with the most powerful detector on the market, this means the instrument is capable of determining samples with C:N and C:S elemental ratios of up to 12,000:1.
- Quiet operation: Thanks to its novel self-regulating air circulation cooling system, UNICUBE is the quietest elemental analyzer in its class. A low noise level - no louder than falling rain - makes working with UNICUBE pleasant to the ear.
- Smart design for optimal ease of use: Maintenance can be minimized and uptime maximized thanks to UNICUBE's clearly arranged and easily accessible system components, as well as its slide-out furnace. The tool-free clamp connection system ensures reliable leak-proof operation at all times, meaning users can enjoy smooth analyses and full confidence in their results.
- Quantitative high-temperature decomposition: UNICUBE functions at a permanent temperature near 1,200°C, reaching 1,800°C during combustion. In pure oxygen, the contained sulfur is fully converted into SO2 with a 100% recovery, even in the case of BaSO4. Carbon is converted to CO2 and detected by a real non-dispersive IR photometer.
- Large dynamic concentration range: UNICUBE's measuring range is 0-100%, or 20 mg S absolute, with just one IR detector and sensitivity range. The measuring range for carbon is 0-100%, or up to 40 mg absolute. Even concentrations of below 1 ppm or 0.2 µg S can be detected.
- Large weighing range: UNICUBE's range encompasses micro (< 1 mg) and macro (1 g) applications, depending on the sample type.
- Direct Temperature Programmed Desorption (direct TPD): The system's direct TPD technology allows gaseous components to be separated perfectly with an optimized TPD column without peak overlap. Time per analysis is also optimized automatically.
- Multipoint calibration: UNICUBE offers reliable stability over months and matrix-independent functionality.
- Instrument parameters are PC-controlled via Windows or Linux: The whole instrument is digitally controlled and can also be operated via the internet, with a 21 CFR Part 11 option for data safety. Because the system is fully digitized, it can be operated remotely.
- One high-performance instrument for all applications: UNICUBE operates without expensive special catalysts, with easy ash removal from the combustion tube and an extended lifetime for all components, helping to ensure a low cost of ownership.
- Clean, safe, fast: The analysis only takes a few minutes, with no aggressive or toxic chemicals required. Helium is used as a carrier gas, or argon as a possible alternative.
- Easy installation requirements: The system takes up a minimal 48 x 55 cm benchtop space, operating with a single power supply (230, 110, 100 V), and two gases sufficient for maintenance-free long-term operation.
... Read More | Matrix-independent determination of N and C at trace levels
The UNICUBE trace measures low-level nitrogen and carbon concentrations in solids and highly viscous liquids with a detection limit of 10 mg/kg. Its speciality: nitrogen and carbon determination are carried out using the Dumas method, Matrix-independent determination of N and C at trace levels
The UNICUBE trace measures low-level nitrogen and carbon concentrations in solids and highly viscous liquids with a detection limit of 10 mg/kg. Its speciality: nitrogen and carbon determination are carried out using the Dumas method, which involves the removal of interfering gases during reduction and subsequent detection of the target gases using a thermal conductivity detector. As such, the UNICUBE trace is able to combine the benefits of the matrix-independent Dumas method with high sensitivity.
With UNICUBE trace, sample digestion is carried out via catalytic combustion at a temperature of 950°C, with the nitrogen and carbon-containing components in the sample forming a mixture of different oxides and N2. The resulting gases then pass through the reduction tube, where carbon compounds are safely reduced to CO2 and nitrogen compounds to N2. After removing other combustion products like H2O and SO2, CO2 and N2 are measured by thermal conductivity detection.
The system is designed for easy, low-maintenance operation; matrix-independent analysis allows the use of a standard ‘universal’ calibration for any sample type. The front door of the analyser opens to give excellent access for the replacement of consumables - exchanging the combustion and reduction tube is simple, thanks to the slide-out furnace.
What’s more, Elementar provides a 10-year warranty on both the furnace and thermal conductivity cell, thus ensuring that UNICUBE trace can continue delivering a stable and reliable performance for laboratories.... Read More | The art of elemental analysis Whether in coal, oil or soil analysis, the elemental analysis of macro samples is a particularly technical challenge for an analyzer. Elementar has solved this task in a sophisticated way by offering the vario MACRO cube. New technical solutions combined with well The art of elemental analysis Whether in coal, oil or soil analysis, the elemental analysis of macro samples is a particularly technical challenge for an analyzer. Elementar has solved this task in a sophisticated way by offering the vario MACRO cube. New technical solutions combined with well proven techniques allow the simultaneous determination of CHNS of samples up to the gram range. The worldwide only analyzer which makes this possible in one fully automatic step.
The elaborate design of the "cube" instruments is good looking and makes this perfect function possible. Ergonomics and functionality are finely linked here. vario MACRO cube can be adjusted to today's and tomorrow's requirements due to its modularity. However, the most important requirement of an analyzer is still the accuracy of the analysis. And vario MACRO cube simply works accurate.... Read More |