Multi Angle Light Scattering / MALS Detector (SEC-MALS)

Multi Angle Light Scattering (MALS) detectors are benchtop systems for characterization and quantification of proteins, peptides, macromolecules, and polymers. A MALS detector is a type of light scattering measurement system, which allows for the detection of light scattered by components of a solution into multiple distinct angles. Many times MALS detectors are coupled with a separation system, such as FFF or SEC.
CompanyWaters | Wyatt TechnologyWaters | Wyatt TechnologyWaters | Wyatt TechnologyWaters | Wyatt Technology
ItemultraDAWN™ Real-Time Multi-Angle Light Scattering (RT-MALS) Detector for PATDAWN™ Multi-angle Light Scattering (MALS) InstrumentmicroDAWN™ Multi-Angle Light Scattering Instrument for UHP-SEC-MALSminiDAWN™ Multi-Angle Light Scattering (MALS) Detector for SEC-MALS
Citations
(1)
Reviews
Catalog NumberultraDAWNDAWNmicroDAWNminiDAWN
Price
DescriptionThe ultraDAWN™ instrument provides real-time product attributes for bioprocess monitoring and control. This instrument is a unique multi-angle light scattering (MALS) instrument, designed for monitoring key attributes like aggregation, polymerization, or conjugation of macromolecules and ... Read MoreThe DAWN™ instrument is an advanced detector for precise characterization of proteins, polymers, and nanoparticles including viral vectors, lipid nanoparticles and vesicles. Using multi-angle static light scattering (MALS) and optional dynamic light scattering (DLS), DAWN analyzes molar mass... Read MoreThe microDAWN™ MALS detector performs absolute characterization of macromolecules eluting from UHPLC (or UPLC), determining molar mass and size independently of retention time and molecular reference standards. This instrument offers superb sensitivity over a wide range of molar mass, size and... Read MoreCouple the miniDAWN™ to your favorite HPLC or FPLC to determine the absolute molar masses and sizes of macromolecules and nanoparticles in solution from hundreds to millions of Daltons—without the need for column calibration standards. This sensitive unit requires as little as 25 ng injected ... Read More
TypeMALSMALS and optional DLSMALS and optional DLSMALS and optional DLS
Measuring RangeMW 1 kDa to 1 GDa, Radius 10 nm to 250 nm200 Da to 1000 MDa200 Da to 10 Mda; 1MDa polymers200 Da to 10 Mda; 1MDa polymers
Detector(s)High-gain, high dynamic range photodiodes at 18 detection anglesHigh-gain, high-dynamic-range photodiodes at 18 angles for MALS; optional avalanche photodiode that may be placed at any of four angles for DLS.
Fluorescence-blocking filters available for use with analytes that fluoresce when illuminated at the MALS wavelength.
High-gain, high dynamic range, static light scattering detectors at 3 anglesHigh-gain, high-dynamic range photodiodes at 3 detection angles for MALS. Optional avalanche photodiode for simultaneous dynamic light scattering measurements.
Light Source658 nm diode laser, progrmmable from 10% to 100% maximum power658 nm laser, programmable 10% - 100% of maximum power.

Optional: 785 nm for fluorescence suppression
660 nm laser, programmable 10% - 100% of maximum power.658 nm laser, programmable from 10% to 100% maximum power.
Wavelength(s)Inquire658 nm; 785 nm available for fluorescence reduction (with lower sensitivity than 658 nm)660 nm658 nm ± 4 nm