| | | | | |
Company | Entegris | Entegris | Entegris | Entegris | Entegris |
Item | Nicomp Nano Z3000 Zeta Potential Analyzer | AccuSizer APS Particle Analyzer System | AccuSizer Mini LE System | AccuSizer Mini Liquid Particle Count and Size Analyzer | Nicomp N3000 Online System |
Citations | | | | | |
Catalog Number | Z3000 | APS700 | MINILE1 | AccuSizer Mini Liquid Particle Count and Size Analyzer | NO300 |
Price | | | | | |
Description | ZETA POTENTIAL ANALYZER
Nicomp Nano Z3000 System
Combines Dynamic Light Scattering (DLS) sizing capability with both frequency and Phase Analysis Light Scattering (PALS) modes for measuring zeta potential
With an electric field that can be varied from 1 to 250 Volts/cm, one instrument can be used ZETA POTENTIAL ANALYZER
Nicomp Nano Z3000 System
Combines Dynamic Light Scattering (DLS) sizing capability with both frequency and Phase Analysis Light Scattering (PALS) modes for measuring zeta potential
With an electric field that can be varied from 1 to 250 Volts/cm, one instrument can be used to analyze zeta potential in aqueous and organic solvents
Cost of ownership is minimized with easy-to-use dip cell and inexpensive ZRS zeta potential standard
Standard Zeta Features
- Phase Analysis Light ScatteringPat. – utilizing a DSP based PALS technique to measure small doppler shifts in the phase of the light scattered from a suspension allowing you to determine the zeta potential in high ionic strength or high dielectric environments (organics).
- Frequency Analysis Mode – provides a frequency domain zeta measurement. This is very useful in obtaining distribution information on the mean zeta potential value as well as a great tool for providing information on the system alignment in service mode.
- Dip Cell Electrodes – these electrodes can be dipped directly into a disposable cuvette which provides for a uniform electric field between the electrode pair, eliminating the need for the stationary plane determination. These electrodes are made from a rugged palladium tip design which provides a durable dip cell design that has a long-life cycle.
- High Voltage Zeta Potential Cell – measures at higher electric field strengths (up to 250V/cm) in organic solvents.
- Electric Field Strength Compensation – Constant current mode that compensates for fall in the electric field during a sample analysis.
- Polarization Correction – provides a correction for the polarization effects in the Phase Analysis Mode PALS to provide an accurate zeta potential value.
... Read More | The AccuSizer is a sophisticated high-resolution particle counter and particle size analyzer that uses the technique of singal particle optical sizing (SPOS). The major benefits of this technique include:
- High Accuracy: Each particle is measured directly
- Concentratation: accurate particles/mL
The AccuSizer is a sophisticated high-resolution particle counter and particle size analyzer that uses the technique of singal particle optical sizing (SPOS). The major benefits of this technique include:
- High Accuracy: Each particle is measured directly
- Concentratation: accurate particles/mL results
- Resolution: no distribution broadening, split multiple peaks to baseline, detect small concentration of tails
AccuSizer APS System
- Uses a unique, two-stage fluidics system that measures particle size and count in high concentration suspensions
- Ideal for high concentration ink samples and for USP <729> testing of lipid injectable emulsions729>
... Read More | The AccuSizer Mini system is engineered using a modular design that allows us to match sensors and fluidics options to customer slurries and process equipment. Our systems generate the highest accuracy and resolution results quickly and at count rates higher than any other technology. This improves The AccuSizer Mini system is engineered using a modular design that allows us to match sensors and fluidics options to customer slurries and process equipment. Our systems generate the highest accuracy and resolution results quickly and at count rates higher than any other technology. This improves statistics to assure detection of large particle counts (LPC) that reduce yields.
- A variety of custom autodilution modules assure the perfect concentration is delivered to the sensor for measurement
- Using the single particle optical sizing (SPOS) technique, a range of sensors operating at focused size ranges and concentration limits provide the highest accuracy results
- Use this system to continuously monitor LPC in your CMP slurry delivery system and as a tool to optimize filtration and other process conditions
AccuSizer Mini LE System
- Range: 0.5 - 400 µm, up to 9,000 particles/mL
- Single or dual stage dilution fluidics
- Ideal for silica CMP slurries
... Read More | The AccuSizer Mini system is engineered using a modular design that allows us to match sensors and fluidics options to customer slurries and process equipment. Our systems generate the highest accuracy and resolution results quickly and at count rates higher than any other technology. This improves The AccuSizer Mini system is engineered using a modular design that allows us to match sensors and fluidics options to customer slurries and process equipment. Our systems generate the highest accuracy and resolution results quickly and at count rates higher than any other technology. This improves statistics to ensure the detection of large particle counts (LPC) that reduce yields or product quality.
- A variety of custom auto-dilution modules ensure the perfect concentration is delivered to the sensor for measurement.
- Using the single particle optical sizing (SPOS) technique, a range of sensors operating at focused size ranges and concentration limits provide the highest accuracy results.
- Use this system to continuously monitor LPC in your CMP slurry delivery system and as a tool to optimize filtration and other process conditions.
... Read More | Dynamic light scattering (DLS) is the most prevalent size analysis technique for nanoparticles. Although the vast majority of DLS size measurements are performed in the laboratory, the nanotechnology revolution has created higher demand for online DLS systems and the Nicomp® Online is a proven Dynamic light scattering (DLS) is the most prevalent size analysis technique for nanoparticles. Although the vast majority of DLS size measurements are performed in the laboratory, the nanotechnology revolution has created higher demand for online DLS systems and the Nicomp® Online is a proven industrial solution. Our Nicomp online system allows users to monitor a manufacturing process to ensure a high quality product without waste.
Nicomp N3000 Online System
- Using dynamic light scattering (DLS) technology, this online system couples a compact optics bench with our unique autodilution fluidics, all rugged enough for the production environment
- Autodilution allows even concentrated materials like paint to be monitored
- Special trending graphs in the software can be used to set out-of-control (OOC) limits that will signal operations when the end point is reached
- The system is small enough to be integrated with many nanoparticle processes, providing real-time particle size distributions
... Read More |
Type | Phase Analysis Light ScatteringPat. | Single Particle Optical Sizing | Single Particle Optical Sizing | Inquire | Dynamic Light Scattering |
Particle Size | 0.3 nm– 10 µm | Inquire | Inquire | Inquire | Inquire |
Detector(s) | 15 – 100 mW red laser diodes, 20 – 100 mW green laser diodes | Extinction, Scattering, Collimated, and/or Focused (sensor dependent) | Extinction, Scattering, Collimated, and/or Focused (sensor dependent) | Inquire | PMT standard, optional 7X gain APD |
Applications | Materials Testing, Pharmaceutical Lab | Materials Testing, Pharmaceutical Lab | Materials Testing, Pharmaceutical Lab | CMP slurries, other suspensions | Materials Testing, Pharmaceutical Lab |
Get Quote | | | | | |