Description | The MDGC/GCMS-2010 is a MDGC system which gives you a excellent separation performance and high reproducibility with the multi-deans switching technology, and supports analyses of complex matrixes like petroleum products, aromas, and optical isomers, with intuitive operation, and ease of maintenance The MDGC/GCMS-2010 is a MDGC system which gives you a excellent separation performance and high reproducibility with the multi-deans switching technology, and supports analyses of complex matrixes like petroleum products, aromas, and optical isomers, with intuitive operation, and ease of maintenance.
Multi-Dimensional GC/GCMS System:
A multi-dimensional GC/GCMS system performs separation using two columns that have different characteristics. The system has a mechanism in which the components that are insufficiently separated in the first column they pass through (the "1st column") are introduced ("heart-cut") to a second, different column (the "2nd column"). This enables analysis with a level of separation that cannot be attained in conventional single-column analysis.
Outstanding retention time stability :
In the past, samples have been introduced to columns using the switching mechanism known as Deans-switching. However, this system results in such problems as a reduced recovery rate and fluctuations in the retention time.
The MDGC/GCMS-2010 system incorporates multi-Deans switching, a new mechanism that significantly reduces the likelihood of fluctuations in the retention times of eluted components, even if switching is performed several times.
A Wide Variety of Optional Systems :
In addition to GCMS, various other detectors, such as an FID or FPD, can be used with the MDGC/GCMS-2010. For example, a headspace sampler and thermal desorption system can be connected and controlled as a pretreatment system. When not using the MDGC/GCMS-2010 as an MDGC system, it is possible to use the GC and GCMS components as independent systems by changing the column and detector connections.
... Read More | The Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system offering enhanced sensitivity and reliability, excellent maintainability, and automation functions.
Key features include:
- Horizontally positioned redox cell – ensures an ample reaction time and reaction zone within
The Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system offering enhanced sensitivity and reliability, excellent maintainability, and automation functions.
Key features include:
- Horizontally positioned redox cell – ensures an ample reaction time and reaction zone within the cell, which promotes the sample's redox reaction and achieves long-term stability
- Simplified maintenance – the unique horizontal design of the redox cell makes it quicker to access and replace the inner pyro-tube without disassembling the redox cell.
- First ultrashort flow path (patent pending) – as the flow path becomes shorter, the sensitivity for both peak area and signal-to-noise ratio increases by up to 2.5 times
- Automation functions – enables operators to finish preparations such as gas control, temperature control and conditioning with a single touch
... Read More |