Detector(s) | Flame Ionization Detector (FID), Flame Photometric Detector (FPD), Electron Capture Detector (ECD) | up to 4 Installed - FID, TCD, ECD, FPD, FTD | GCMS, FID, FPD, TCD, ECD, FTD | FID, FPD, BID, ECD, TCD, FTD/NPD) | Inquire |
Description | The compact, high-performance Brevis GC-2050 gas chromatograph delivers best-in-class analytical performance and scalability in an ultra-compact design. Despite the 35% reduction in footprint, the Brevis GC-2050 can be configured with a variety of detectors and sample introduction techniques, The compact, high-performance Brevis GC-2050 gas chromatograph delivers best-in-class analytical performance and scalability in an ultra-compact design. Despite the 35% reduction in footprint, the Brevis GC-2050 can be configured with a variety of detectors and sample introduction techniques, including dual-line configurations, using industry-standard columns and consumables. In addition, the system includes insulating materials and a smaller oven to reduce the thermal capacity and thoroughly eliminate heat loss, reducing power consumption by 30% compared to conventional models
Features:
- Versatile system configurations with choice of sample introduction units and detectors
-
Use of up to two general capillary columns
-
Reduced helium usage via carrier gas save mode
-
Remote display monitoring and control
-
Simplified maintenance and tool-less column installation
-
Quick, efficient automatic conditioning
-
Allows use of hydrogen as the carrier gas
-
Optional gas selector achieves additional gas savings by automatically switching the gas from helium to an alternative gas
LabSolutions Direct, a standard feature of the LabSolutions software platform, enables users to monitor instrument status and chromatographic signals, start and stop the instrument and begin analysis from a web browser on a PC or smart device at a remote office or home.... Read More | The versatile GC-2014 offers outstanding expandability with the capability of mounting multiple injection units and detectors, and accommodating both packed columns and capillary columns. A multipurpose, space-saving GC that features today's leading-edge technologies, the GC-2014 delivers high The versatile GC-2014 offers outstanding expandability with the capability of mounting multiple injection units and detectors, and accommodating both packed columns and capillary columns. A multipurpose, space-saving GC that features today's leading-edge technologies, the GC-2014 delivers high performance, including excellent reproducibility and a highly sensitive detection level, while the electronic flow controller and clear menu text make operation a breeze.
- System contains seven on-board heated zones and sixteen 24-volt relays all which can be controlled via the LabSolutions software
- Can accommodate up to four GC detectors
- Ability to configure glass packed, stainless steel packed, wide-bore, and narrow-bore columns
- Rugged chassis and narrow footprint make it ideal for any lab
- Flexibility and large oven capacity make it the perfect platform for the System GC program
... Read More | The MDGC/GCMS-2010 is a MDGC system which gives you a excellent separation performance and high reproducibility with the multi-deans switching technology, and supports analyses of complex matrixes like petroleum products, aromas, and optical isomers, with intuitive operation, and ease of maintenance The MDGC/GCMS-2010 is a MDGC system which gives you a excellent separation performance and high reproducibility with the multi-deans switching technology, and supports analyses of complex matrixes like petroleum products, aromas, and optical isomers, with intuitive operation, and ease of maintenance.
Multi-Dimensional GC/GCMS System:
A multi-dimensional GC/GCMS system performs separation using two columns that have different characteristics. The system has a mechanism in which the components that are insufficiently separated in the first column they pass through (the "1st column") are introduced ("heart-cut") to a second, different column (the "2nd column"). This enables analysis with a level of separation that cannot be attained in conventional single-column analysis.
Outstanding retention time stability :
In the past, samples have been introduced to columns using the switching mechanism known as Deans-switching. However, this system results in such problems as a reduced recovery rate and fluctuations in the retention time.
The MDGC/GCMS-2010 system incorporates multi-Deans switching, a new mechanism that significantly reduces the likelihood of fluctuations in the retention times of eluted components, even if switching is performed several times.
A Wide Variety of Optional Systems :
In addition to GCMS, various other detectors, such as an FID or FPD, can be used with the MDGC/GCMS-2010. For example, a headspace sampler and thermal desorption system can be connected and controlled as a pretreatment system. When not using the MDGC/GCMS-2010 as an MDGC system, it is possible to use the GC and GCMS components as independent systems by changing the column and detector connections.
... Read More | Nexis GC-2030, Shimadzu’s premier gas chromatograph, offers a modern approach to a classic chromatographic technique. Designed with the user in mind, new innovative features, exceptional performance and high-throughput capabilities will elevate your lab to the next level.
Features/benefits
Nexis GC-2030, Shimadzu’s premier gas chromatograph, offers a modern approach to a classic chromatographic technique. Designed with the user in mind, new innovative features, exceptional performance and high-throughput capabilities will elevate your lab to the next level.
Features/benefits
- Faster ROI with versatile, expandable configurations – allows for up to three analytical lines for greater productivity or for the versatility of more analyses to be packaged into one GC
- Reduced operating costs with Eco mode – optimizes the use of carrier gas such as helium and reduces electricity use when idle
- Improved workflow with touch-panel interface and remote communications – ensures easy monitoring of the system’s operating status
- Increased productivity with tool-free column installation and inlet maintenance
- Optional, built-in sensor to monitor real time levels of hydrogen in the oven
Further enhancing productivity is LabSolutions workstation software that fully integrates LC and GC functionality. It offers both easy operability and extensive functionality. This includes a new data browser, convenient for comparing multiple sets of data simultaneously, and a Quick-Batch Function that simplifies the tedious process of creating injection sequences.... Read More | The Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system offering enhanced sensitivity and reliability, excellent maintainability, and automation functions.
Key features include:
- Horizontally positioned redox cell – ensures an ample reaction time and reaction zone within
The Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system offering enhanced sensitivity and reliability, excellent maintainability, and automation functions.
Key features include:
- Horizontally positioned redox cell – ensures an ample reaction time and reaction zone within the cell, which promotes the sample's redox reaction and achieves long-term stability
- Simplified maintenance – the unique horizontal design of the redox cell makes it quicker to access and replace the inner pyro-tube without disassembling the redox cell.
- First ultrashort flow path (patent pending) – as the flow path becomes shorter, the sensitivity for both peak area and signal-to-noise ratio increases by up to 2.5 times
- Automation functions – enables operators to finish preparations such as gas control, temperature control and conditioning with a single touch
... Read More |