Description | Shimadzu's Comprehensive GC-MS (GCxGC-MS) System is comprised of a combination of our fast scanning, high-sensitivity quad GCMS-QP2010Ultra and the Zoex Corporation series of modulators, ZX-1 or ZX-2. The QP2010Ultra is the only quadrupole mass spectrometer on the market that scans fast enough to Shimadzu's Comprehensive GC-MS (GCxGC-MS) System is comprised of a combination of our fast scanning, high-sensitivity quad GCMS-QP2010Ultra and the Zoex Corporation series of modulators, ZX-1 or ZX-2. The QP2010Ultra is the only quadrupole mass spectrometer on the market that scans fast enough to fully characterize the 100msec to 600msec peaks created by the modulation process. More economically priced than a TOF-MS, the quadrupole-MS has the added capability of Chemical Ionization and Negative Chemical Ionization for molecular ion spectral analysis and electrophyllic compound selectivity. The spectra generated by quad-MS are easily matched by the standard commercially available libraries such as the NIST, Wiley and FFNSC.
This system is available in a variety of configurations for complete control of your analysis. A second, full function, GC oven, with heated transfer line, can be added to the GCMS system that will allow separate temperature control of the first and second dimensional columns. It is also possible to incorporate our line of Advanced Capillary Flow products such as detector splitting packages, deans switching and backflush kits.
Features
- Separation of Overlapping Peaks
- Image Patterns Show Compound Structure
- Data Analysis Software, GC Image
... Read More | The MDGC/GCMS-2010 is a MDGC system which gives you a excellent separation performance and high reproducibility with the multi-deans switching technology, and supports analyses of complex matrixes like petroleum products, aromas, and optical isomers, with intuitive operation, and ease of maintenance The MDGC/GCMS-2010 is a MDGC system which gives you a excellent separation performance and high reproducibility with the multi-deans switching technology, and supports analyses of complex matrixes like petroleum products, aromas, and optical isomers, with intuitive operation, and ease of maintenance.
Multi-Dimensional GC/GCMS System:
A multi-dimensional GC/GCMS system performs separation using two columns that have different characteristics. The system has a mechanism in which the components that are insufficiently separated in the first column they pass through (the "1st column") are introduced ("heart-cut") to a second, different column (the "2nd column"). This enables analysis with a level of separation that cannot be attained in conventional single-column analysis.
Outstanding retention time stability :
In the past, samples have been introduced to columns using the switching mechanism known as Deans-switching. However, this system results in such problems as a reduced recovery rate and fluctuations in the retention time.
The MDGC/GCMS-2010 system incorporates multi-Deans switching, a new mechanism that significantly reduces the likelihood of fluctuations in the retention times of eluted components, even if switching is performed several times.
A Wide Variety of Optional Systems :
In addition to GCMS, various other detectors, such as an FID or FPD, can be used with the MDGC/GCMS-2010. For example, a headspace sampler and thermal desorption system can be connected and controlled as a pretreatment system. When not using the MDGC/GCMS-2010 as an MDGC system, it is possible to use the GC and GCMS components as independent systems by changing the column and detector connections.
... Read More |