Description | The DMA 242 E Artemis combines ease of handling with the user-friendly Proteus® measurement and evaluation software. This makes it fast and easy to characterize the dynamic-mechanical properties as a function of frequency, temperature and time.
Its modular design along with a wide variety of The DMA 242 E Artemis combines ease of handling with the user-friendly Proteus® measurement and evaluation software. This makes it fast and easy to characterize the dynamic-mechanical properties as a function of frequency, temperature and time.
Its modular design along with a wide variety of sample holders and cooling systems allow the DMA 242 E Artemis to handle a broad range of applications and samples.
Various add-on options make it the ideal device for any laboratory and a safe investment for the long-term.
- Hang-down design
for easy accessibility, handling and changing of the different sample holders - Over 30 different sample holders
for optimal adjustment of measurement conditions to material properties - Controlled gas flow (inert or oxidizing)
with optimal heat transfer on samples for defined measurement conditions - Various cooling options.
Two different cooling systems; liquid nitrogen-controlled cooling to -170°C and compressed-air cooling with vortex tube to cool to 0°C - Controlled force range up to 24 N
(12 N static and 12 N dynamic) for measurements of very stiff samples. Increased resolution in the measuring range 4 N static and 4 N dynamic - A stepper motor with a 20-mm travel range
allows for precise testing on materials which exhibit substantial changes in length during a DMA measurement. This is particularly important for the different static experiments available with the DMA 242 E Artemis; i.e., creep, relaxation and TMA mode. ... Read More | Take Control of the Dynamic-Mechanical Properties of Your Products
The DMA 303 Eplexor® is a highly precise and reliable analysis instrument that can handle a wide range of samples and applications. With its user-friendly software and improved ergonomics, it's the ideal device for intensive use in Take Control of the Dynamic-Mechanical Properties of Your Products
The DMA 303 Eplexor® is a highly precise and reliable analysis instrument that can handle a wide range of samples and applications. With its user-friendly software and improved ergonomics, it's the ideal device for intensive use in research and quality control laboratories.
The DMA 303 Eplexor® is extremely versatile and designed to handle a wide range of samples and applications. Thanks to its various accessories, such as sample holders and cooling systems, it can accommodate a variety of different testing requirements.
In addition to its user-friendly software, the DMA 303 Eplexor® features significantly improved ergonomics, making it pleasant to operate on a daily basis. Its various add-on options make it an ideal device to use and a safe long-term investment.
Features:
- Controlled Force Range up to 50 N (static and dynamic) -
Our material testing system is designed for precision measurements on very stiff samples with a controlled force range, both static and dynamic, of up to 50 N. The full resolution is available throughout the entire force range, resulting in precise and reliable data. -
Temperatures of up to 800°C on the Sample -
Featuring the broadest temperature range of -170°C to 800°C and homogeneous temperature distribution. -
Time Saving - Fast Heating and Cooling -
With its thin-walled 3D-printed silicon carbide furnace lining, our system reduces waiting times with fast heating and cooling and allows for homogeneous temperature distribution due to two independent temperature control loops. -
Perfect for the Execution of Creep and Relaxation Experiments -
The independent stepper motor drive with its range of up to 30 mm is perfect for non-oscillatory experiments like tensile or compression tests, creep and relaxation. -
Suspended Sample Holder Design -
The suspended sample holder system, in combination with the ability to adjust the height of the instrument, support the best possible ergonomics at the workplace. In addition, this setup protects the sensitive measuring system from the intrusion of falling sample fragments. -
Various Cooling Options to Suit Your Requirements -
i.e., liquid nitrogen-controlled cooling down to -170°C, or AIC 80 intracooler for measurements below room temperature down to -70°C. ... Read More | DMA Eplexor® HT Series up to 500 N - For ceramics, metals, alloys, glasses, composites and more
The DMA GABO Eplexor® HT line is the only instrument series on the market which is able to carry out DMA measurements with a maximum dynamic force of 500 N to 1500°C.
Two high-temperature furnaces DMA Eplexor® HT Series up to 500 N - For ceramics, metals, alloys, glasses, composites and more
The DMA GABO Eplexor® HT line is the only instrument series on the market which is able to carry out DMA measurements with a maximum dynamic force of 500 N to 1500°C.
Two high-temperature furnaces are available: RT to 1000°C and RT to 1500°C. With a standard furnace (-160°C to 500°C) simultaneously mounted, it is possible to perform consecutive test runs in both the low- and high-temperature range. Eplexor® HT instruments can thus cover the entire temperature span from -160°C to 1500°C.
The electronics within the system automatically identify which furnace is currently in use.
The following DMA GABO Eplexor® HT are available:
DMA GABO Eplexor® 25N HT,
DMA GABO Eplexor® 100N HT,
DMA GABO Eplexor® 150N HT,
DMA GABO Eplexor® 500N HT,
DMA Eplexor® up to 500 N - High-Force DMA
The testing instruments of the DMA GABO Eplexor® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids.
The modular design of the high-force DMA systems allows for measurements in the tension, compression, bending and shearing modes. The testing machines in this series differ from each other mainly in terms of their maximum dynamic force ranges of ±25 N, ±100 N, ±150 N and ±500 N.
Various add-on options make these testing machines a safe investment for the long-term.
All testing machines in this series are conform to standards such as DIN 53513, ISO 6721/1, ISO 6721/4, ISO 6721/5, ISO 6721/6, ISO 4664, ASTM D4065, and ASTM D4473.
DMA 523 Eplexor® High-Force Series- For Large and High-Modulus Samples
The instruments in our high-force Eplexor® series offer static and additional dynamic force levels from max. ± 2000 N to max. ± 4000 N, and are thus the perfect choice for investigating the dynamic-mechanical (or only static) properties of rigid samples as well as of specimens with larger dimensions – even component parts.
Thanks to their modular design, high-force DMA instruments can accommodate add-ons to additionally carry out tests on such properties as fatigue, heat build-up, blow-out and rolling resistance.
All testing machines in this series are based on standards such as DIN 53513, DIN 53533, ISO 6721/1, ISO 6721/4, ISO 6721/5, ISO 6721/6, ISO 4664, ISO 4666/3, ISO 4666/4, ASTM D623, ASTM D4065, and ASTM D4473.
The following high-force DMA instruments are available:
DMA 523 Eplexor® (2000 N),
DMA 523 Eplexor® (4000N)... Read More | Accurate measurements of heat build-up or blowout processes and the determination of the thermal set can be realised by our HBU 523 Gabometer system – a development based on the established Goodrich Flexometer.
Both force- and elongation-controlled tests can be carried out with this state-of-the-Accurate measurements of heat build-up or blowout processes and the determination of the thermal set can be realised by our HBU 523 Gabometer system – a development based on the established Goodrich Flexometer.
Both force- and elongation-controlled tests can be carried out with this state-of-the-art type of flexometer. The HBU 523 Gabometer is suitable for improving the thermal dissipation and the durability of semi-finished tire components, dampers or absorbers.
Additionally, the new generation allows for measurement of the material stiffness (E modulus, tand option) and damping.
Advantages
- Heat build-up and blowout tests according to Goodrich (DIN 53533, ASTM D 623, ISO 4666/3, ISO 4666/4, BS 903 part A50 and JIS K 6265)
- Goodrich flexometer tests
- Static:
strain or stress controlled load mode available
- Dynamic:
strain or stress controlled load mode available
- Wide frequency range (option)
- Wide temperature range (option)
- Automatic Sample Changer (ASC) for fully automatic testing (24h) (option)
- Simultaneous measurement of the visco-elastic properties (option)
- Visco-elastic properties in DMTS/DMA mode (option)
- Hysteresis analysis (option)
- Pulse load mode available (option)
... Read More |
Applications | Mode of Deformation: 3-point bending, Single / dual cantilever bending Shearing, Tension, Compression / penetration | Inquire | Eplexor® HT;
Bending Test on Bauxite,Bending and Softening of
an Al2O3/Metal Compound
DMA Eplexor® Series; Filler-Filler Interactions,Time-Temperature
Superposition, Thermal Treatment of PP,Low Damping Behavior of
Magnesium
DMA 523 Eplexor ® Series; Fatigue Test on Reinforced, Tensile Test on Reinforced, Hysteresis on Micro-Cellular Polyurethane, Low-Force Temperature Sweep Test on EPDM
| Fatigue Test on Reinforced, Tensile Test on Reinforced, Hysteresis on Micro-Cellular Polyurethane, Low-Force Temperature Sweep Test on EPDM |