Description | The Shimadzu Cannabis Analyzer for Potency captures the spirit of an Analyzer – a comprehensive package integrating instrument hardware, software, consumables, and analytical workflow. Includes a certified reference material (CRM) mixture of target compounds. Also includes a service package to coverThe Shimadzu Cannabis Analyzer for Potency captures the spirit of an Analyzer – a comprehensive package integrating instrument hardware, software, consumables, and analytical workflow. Includes a certified reference material (CRM) mixture of target compounds. Also includes a service package to cover preventive maintenance and warranty for three years, plus free technical support for the life of the product. The solution is ready to use after one day of installation and testing, and requires no time-consuming method development on the part of the analyst.
Choice of three proven HPLC methods:
- High Throughput HPLC Method Package – Designed for analysis of the 10 most commonly requested cannabinoids in under 8 minutes. This is the original method developed by Shimadzu in collaboration with industry laboratories. (Does not include THCV.)
- High Sensitivity HPLC Method Package – Adds THCV to the target analyte list, with an instrument cycle time of under 10 minutes. The short analysis time produces the sharpest chromatographic peaks for the best overall sensitivity.
- High Resolution HPLC Method Package – Presents full baseline resolution for all 11 compounds and an analysis time under 30 minutes. This method is preferred for research purposes, or when additional compounds must be added to the analysis in response to new state regulatory requirements.
... Read More | Automatically and seamlessly conducting all processes from sample pre-treatment to analysis, the Prominence 2D HPLC for BA is a column-switching HPLC system equipped with the newly developed Shim-pack MAYI-ODS pretreatment column and a unique on-line dilution bypass channel. The system’s on-line preAutomatically and seamlessly conducting all processes from sample pre-treatment to analysis, the Prominence 2D HPLC for BA is a column-switching HPLC system equipped with the newly developed Shim-pack MAYI-ODS pretreatment column and a unique on-line dilution bypass channel. The system’s on-line pre-treatment of bio-samples reduces labor while enhancing efficiency. A high-throughput autosampler provides high-speed injection and reproducibility. Accurate and precise temperature control of the system further ensures reproducible analysis and a high recovery rate. Key features include: - Shim-pack MAYI-ODS Pretreatment Column – This unique column effectively removes proteins from bio-samples, achieves long-term stability through optimization of particle diameter and newly developed coating technology, and exhibits excellent repeatability
- On-line Dilution Bypass Effect – Eliminates the need for preliminary dilution of the sample by automatically diluting it on-line, leading to excellent recovery rates
- Suppression of Carryover – A number of enhancements, including a specially treated outer needle surface and improvement of needle seal composition, greatly reduce sample adsorption, critical for achieving the high sensitivity of LC-MS/MS
- Precise Temperature Control of the Pretreatment Column
This system serves as a front-end HPLC system for a mass spectrometer, enhancing the efficiency of analyzing drugs in bio-samples in pharmacokinetics studies and clinical tests. ... Read More | Method scouting is a process where different mobile phases and column stationary phases are evaluated to determine the best set of separation conditions for a particular sample. Manual solvent preparation, column switching, and method programming are time-consuming steps, so the Nexera method Method scouting is a process where different mobile phases and column stationary phases are evaluated to determine the best set of separation conditions for a particular sample. Manual solvent preparation, column switching, and method programming are time-consuming steps, so the Nexera method scouting system was developed to streamline the entire process for more efficient method development.
The system is based around 2 LC-30AD pumps, each with a quaternary valve, which allows the analyst to run binary gradients with 16 different solvent pairs. A high-pressure column selection valve holds from 1 to 6 columns, resulting in up to 96 unique separation conditions per sample. Ultra-high speed conditions can be easily transferred to conventional conditions using a transfer program. In addition, scouting is performed automatically when the mobile phase is switched.
The Nexera Method Scouting Solution software has intuitive, user-friendly screens to set the pump and column valve positions, gradient program steps, and it automatically builds the sequence table in seconds. Method Scouting Solution provides the data required for analysis via a graphical user interface, as well as automated controls conforming to laboratory operations configured in the system settings.
... Read More | Enables Both HPLC and UHPLC Analysis
The Nexera-i MT is a new addition to the i-Series lineup. It enables both conventional analysis via its high compatibility with existing LC systems and rapid analysis via high-speed methods. In pharmaceutical development, a single integrated system allows Enables Both HPLC and UHPLC Analysis
The Nexera-i MT is a new addition to the i-Series lineup. It enables both conventional analysis via its high compatibility with existing LC systems and rapid analysis via high-speed methods. In pharmaceutical development, a single integrated system allows process synthesis screening analysis for synthetic substances in the UHPLC flow line, and impurity content identification in the HPLC flow line.
Analysis results from LC systems in the same laboratory may differ, even with the same method, due to differences in the volumes of these systems. The Nexera-i MT demonstrates outstanding reproducibility between various LC systems with different system volumes, simplifying method transfer between instruments.
Further more, with the Nexera-i MT the process of migrating from UHPLC to HPLC or from HPLC to UHPLC can be accomplished using a single system. The Nexera-i MT is based on the same user-friendly i-Series, but maximizes performance and reliability for migrating and transferring customer methods.... Read More | The SCL-40 features a built-in reservoir tray and color LCD touch screen, stacking neatly on top of the main system components. Other LC modules connect via fiber optic cables for easy "plug and play" system configuration. An internal web server offers convenient control and monitoring of the UHPLC The SCL-40 features a built-in reservoir tray and color LCD touch screen, stacking neatly on top of the main system components. Other LC modules connect via fiber optic cables for easy "plug and play" system configuration. An internal web server offers convenient control and monitoring of the UHPLC system through a web browser or other third-party software.
Features:
- Connection via Ethernet
- Offers 8 Fiber Optic ports for controlling other system components
... Read More |