Description | Building on the exceptional performance of previous versions, the integrated i-Series LC-2050/LC-2060 models incorporate Analytical Intelligence functions, enable complete automation from start-up to analysis preparations, and allow remote monitoring and data processing. In addition, the easy-to-useBuilding on the exceptional performance of previous versions, the integrated i-Series LC-2050/LC-2060 models incorporate Analytical Intelligence functions, enable complete automation from start-up to analysis preparations, and allow remote monitoring and data processing. In addition, the easy-to-use, easy-access front-panel interface replicates the system flow channel and simplifies the operating status of the system. Method editing can also be easily performed directly from the same screen. With this intuitive design, even users who are completely new to liquid chromatography can navigate the user interface with minimal training.
Features include:
- 14-second injection cycle to support high-speed multi-analyte processing
- Lowest carryover (<0.0025%) with exceptional reproducibility
- Increased sample capacity – autosampler accommodates over 1,500 samples
- UV or PDA detector standard; optional detectors can be added
- Forced air circulation column oven for (ambient -10) to 90 degrees temperature control
- Dual temperature-controlled optics and flow cell for excellent baseline stability
- Analytical intelligence functions, including real-time mobile phase monitoring, smart flow control, and i-PeakFinder automatic peak integration
- Easy migration of existing methods from either Shimadzu or non-Shimadzu systems
With LabSolutions Direct, analysts can operate instruments remotely and implement pre-configured methods using the web browser of a computer or a smart device. Instrument status and chromatograms can also be monitored remotely for increased efficiency and uptime.
The i-Series LC-2050/LC-2060 models feature increased pressure tolerance to enable use for a wider range of analysis conditions. The upper pressure limit for the LC-2050 is 50MPa (7,000psi), and for the LC-2060 is 70MPa (10,000psi).... Read More | Method scouting is a process where different mobile phases and column stationary phases are evaluated to determine the best set of separation conditions for a particular sample. Manual solvent preparation, column switching, and method programming are time-consuming steps, so the Nexera method Method scouting is a process where different mobile phases and column stationary phases are evaluated to determine the best set of separation conditions for a particular sample. Manual solvent preparation, column switching, and method programming are time-consuming steps, so the Nexera method scouting system was developed to streamline the entire process for more efficient method development.
The system is based around 2 LC-30AD pumps, each with a quaternary valve, which allows the analyst to run binary gradients with 16 different solvent pairs. A high-pressure column selection valve holds from 1 to 6 columns, resulting in up to 96 unique separation conditions per sample. Ultra-high speed conditions can be easily transferred to conventional conditions using a transfer program. In addition, scouting is performed automatically when the mobile phase is switched.
The Nexera Method Scouting Solution software has intuitive, user-friendly screens to set the pump and column valve positions, gradient program steps, and it automatically builds the sequence table in seconds. Method Scouting Solution provides the data required for analysis via a graphical user interface, as well as automated controls conforming to laboratory operations configured in the system settings.
... Read More |