Quadrupole Mass Spectrometer (MS) / Quadrupole Mass Analyzer

Quadrupole mass spectrometers are perhaps the simplest of mass spec instruments. Functioning effectively like a radio, the quadrupole MS – so-named because of its four charged rods, which run parallel to the flight paths of the ions it measures – filter ions by mass-to-charge ratio (m/z) by altering the voltages in the rods. Quadrupole mass spectrometers are available in a variety of formats, including a single quadrupole mass spectrometer, a triple quadrupole MS (three quadrupoles arranged in tandem), and a Q-TOF (a triple quad variant in which the third quadrupole is replaced with a time-of-flight mass analyzer).

Quadrupole mass analyzers are often used for targeted, quantitative applications and can be used either to measure one or a few given ions in a mixture, or to scan across a range of m/z values. Depending on the configuration, they can facilitate both MS and MS/MS applications. For instance, in a triple-quadrupole mass spectrometer, you can select ions for analysis in the first quadrupole, fragment them by collision with a gas in the second quadrupole, and analyze the resulting fragmentation ions in the third quadrupole.

Find, compare, and request a quote for quadrupole mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher Scientific
ItemQ Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ Mass SpectrometerThermo Scientific™ Exactive™ Plus EMR Orbitrap™ LC-MS SystemThermo Scientific™ ISQ™ EM Single Quadrupole Mass SpectrometerThermo Scientific™Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ LC-MS/MS Mass SpectrometerTSQ Altis™ MD Mass Spectrometer
Citations
Catalog NumberIQLAAEGAAPFALGMAZRIQLAAEGAAPFALGMBDLIQLAAAGADIFZZZMZZZIQLAAEGAAPFALGMBDKIQLAAEGAAXFAQSMBLC
Price
Ionization Method(s)InquireAPCI, H-ESIAtmospheric pressure ionization (API) source with interchangeable HESI and APCI probesAPCI, H-ESIInquire
Mass AnalyzerUHMR Hybrid Quadrupole-Orbitrap™OrbitrapSingle quadrupoleHybrid Quadrupole / OrbitrapTriple quadrupole
Scanning Speedup to 12 Hz at resolution setting of 12,500 at m/z 400Up to 12 HzUp to 20,000 Da/sec.Up to 12 HzInquire
Mass Range350 to 80,000 m/z350 to 20,000 m/z10 to 2000 m/z with Unit Mass Resolution50 to 6,000 m/z5 to 3000 m/z
DescriptionThe Thermo Scientific™ Q Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ mass spectrometer is the first to provide the unique combination of unprecedented ultra-high mass range resolution, highest sensitivity, and MS2 and pseudo-MS3 capabilities needed to go beyond what’s possible with today’s native MS ... Read MoreWhile analysis of denatured proteins may be the most common LC/MS protein analysis, many biopharmaceutical and biological research applications require analysis of proteins in their native (intact) state. The Thermo Scientific™ Exactive™ Plus EMR mass spectrometer combines unsurpassed high-... Read MoreAdding mass spectrometry (MS) to your liquid chromatography (LC) analyses gives you access to the valuable data that only MS can provide. The new, easy-to-use ISQ™ EM Single Quadrupole Mass Spectrometer seamlessly integrates with LC systems for reliable, robust, and easy LC-MS routine analysis with ... Read MoreTake Quanfirmation™ to the next level. The Thermo Scientific™ Q Exactive™ Hybrid Quadrupole-Orbitrap™ Mass Spectrometer introduced the revolutionary concept of Quanfirmation. The Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer takes Quanfirmation to the next level with increased ... Read MoreAchieve the sensitivity to perform routine quantitative analyses with remarkable speed and robustness. The Thermo Scientific™ TSQ Quantis™ MD Series mass spectrometer can be used by clinical diagnostic laboratories to meet their routine requirements for laboratory developed tests (LDTs). With Active... Read More