LC MS Instrument

Comprising two components, a liquid-phase separation system and a mass spectrometer, liquid chromatograph mass spectrometers (LC MS instruments) couple sample fractionation and analysis. The separation can be accomplished via standard liquid chromatography, HPLC, UPLC, or even nano-LC. Any liquid-phase separation will do, so long as its output can be directed into the mass analyzer (for instance, via an electrospray ionization source). The mass spectrometer is similarly flexible, ranging from the simplest single quadrupole to a Fourier transform ion cyclotron resonance instrument. Just remember, in a liquid chromatograph mass spectrometer the column flow is continuous, meaning the mass analyzer must be fast enough to thoroughly analyze one peak before the next one comes off the column. And, unlike with MALDI MS, once a peak is analyzed, it’s gone.
CompanyThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher Scientific
ItemThermo Scientific™Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ LC-MS/MS Mass SpectrometerThermo Scientific™ Exactive™ Plus EMR Orbitrap™ LC-MS SystemThermo Scientific™ GasBench Plus SystemThermo Scientific™ Orbitrap Eclipse™ Tribrid™ Mass SpectrometerThermo Scientific™ Orbitrap Exploris™ 240 Mass Spectrometer
Citations
(1)
Catalog NumberIQLAAEGAAPFALGMBDKIQLAAEGAAPFALGMBDLIQLAAMGAATFAETMBMZIQLAAEGAAPFADBMBKSIQLAAEGAAPFARBMBKP
Price
Ionization Method(s)APCI, H-ESIAPCI, H-ESIInquireInquireInquire
Mass AnalyzerHybrid Quadrupole / OrbitrapOrbitrapInquireInquireInquire
Scanning SpeedUp to 12 HzUp to 12 HzInquireOTMSn up to 40 Hz ITMSn up to 45 HzInquire
Resolutionup to 280,000 FWHMup to 140,000 FWHMInquire7500 to 500,000 (FWHM) at m/z 200Inquire
DescriptionTake Quanfirmation™ to the next level. The Thermo Scientific™ Q Exactive™ Hybrid Quadrupole-Orbitrap™ Mass Spectrometer introduced the revolutionary concept of Quanfirmation. The Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer takes Quanfirmation to the next level with increased ... Read MoreWhile analysis of denatured proteins may be the most common LC/MS protein analysis, many biopharmaceutical and biological research applications require analysis of proteins in their native (intact) state. The Thermo Scientific™ Exactive™ Plus EMR mass spectrometer combines unsurpassed high-... Read MoreExpand the applications of isotope ratio mass spectrometry (IRMS) with the Thermo Scientific™ GasBench Plus System. This universal on-line gas preparation and introduction system provides a robust solution for high-precision on-line isotope and molecular ratio determination of gaseous samples via ... Read MoreOne system, maximum insights
Today’s cutting-edge research pushes LC-MS to its limits. Obtaining high confidence insights to enable accurate resolution of subtle differences and avoid costly dead-ends is needed faster than ever before. The Thermo Scientific Orbitrap Eclipse Tribrid mass spectrometer
... Read More
The Thermo Scientific Orbitrap Exploris 240 mass spectrometer combines application flexibility with the performance to drive discovery and identification, plus receive the quantitative precision and accuracy you need to confidently scale up and achieve impact. With operational simplicity through ... Read More
QuantityEAEAEAEAEA
TypeInquireInquireContinuous Flow IRMSInquireMass Spectrometer
Get Quote