The Orbitrap, also known as the Kingdon trap, is a type of ion trap mass analyzer employed by certain lines of mass spectrometers. Compared to its other ion trap mass analyzers, the way the orbitrap works is based upon the ion trajectories as they move through the electrode, which follow an orbital path. Ionization can vary by the system, but commonly includes atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI).
Search and compare Orbitrap Mass Spectrometers
| | | | | |
Company | Thermo Fisher Scientific | Thermo Fisher Scientific | Thermo Fisher Scientific | Thermo Fisher Scientific | Thermo Fisher Scientific |
Item | Orbitrap Astral Mass Spectrometer | Thermo Scientific™ Orbitrap™ Ascend Tribrid™ mass spectrometer | Thermo Scientific™ Orbitrap Eclipse™ Tribrid™ Mass Spectrometer | Thermo Scientific™ Orbitrap Exploris™ 480 Mass Spectrometer | Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer |
Citations | | | | | |
Reviews | | | | | |
Catalog Number | Orbitrap Astral Mass Spectrometer | IQLAAEGAAPFADBMBNG | IQLAAEGAAPFADBMBKS | IQLAAEGAAPFARBMBKR | IQLAAEGAAPFADBMBHQ |
Price | | | | | |
Ionization Method(s) | Adjustable heated electrospray ionization (HESI) probe | Inquire | Inquire | Inquire | HESI |
Mass Analyzer | Orbitrap mass analyzer ranging from 7,500 to 480,000 resolution at m/z 200
Astral mass analyzer is operated at a single resolution setting of 80,000 at m/z 524 | Inquire | Inquire | Inquire | Orbitrap |
Scanning Speed | Up to 200 Hz | Inquire | OTMSn up to 40 Hz ITMSn up to 45 Hz | Inquire | Inquire |
Mass Range | Maximum Astral mass analyzer resolution up to 80,000 FWHM at m/z 524
Maximum Orbitrap mass analyzer resolution of up to 480,000 FWHM at m/z 200 | Standard mass range m/z 40 to 2000, mid-mass range m/z 200 to 6000 | 50 to 8000 m/z | 40 to 8000 m/z | m/z 50–2,000
m/z 200–4,000
up to m/z 6,000 without precursor ion selection (OTMS only) |
Description | Inquire | Scale your science for protein and biopharmaceutical characterization. Increased throughput, versatility, and ease-of-use, the Thermo Scientific™ Orbitrap™ Ascend Tribrid mass spectrometer accelerates proteomics and native protein analyses. | One system, maximum insights Today’s cutting-edge research pushes LC-MS to its limits. Obtaining high confidence insights to enable accurate resolution of subtle differences and avoid costly dead-ends is needed faster than ever before. The Thermo Scientific Orbitrap Eclipse Tribrid mass spectrometerOne system, maximum insights Today’s cutting-edge research pushes LC-MS to its limits. Obtaining high confidence insights to enable accurate resolution of subtle differences and avoid costly dead-ends is needed faster than ever before. The Thermo Scientific Orbitrap Eclipse Tribrid mass spectrometer surpasses these limits with new innovations that deliver the ultimate flexibility to expand experimental scope, and with built-in intelligence to ensure the highest data quality and confidence. One system provides maximum insights, so you productively go beyond today’s discovery.... Read More | Making genius simpler Empowering life science researchers to translate each experimental step to a new level of insight with a next-generation ownership experience coupled with an intelligence-driven experimental approach. With the Thermo Scientific Orbitrap Exploris 480 mass spectrometer you'll Making genius simpler Empowering life science researchers to translate each experimental step to a new level of insight with a next-generation ownership experience coupled with an intelligence-driven experimental approach. With the Thermo Scientific Orbitrap Exploris 480 mass spectrometer you'll find market leading quantitative performance to solve your most complex challenges with ease, and the proven qualitative performance you expect.
From exploratory to targeted quantitation, find the power and reliability to make large scale studies possible, while reducing everyday hassles as you increase productivity. And achieving it all, remarkably, within a compact footprint. An extraordinary instrument, providing extraordinary results.... Read More | Excel at the most challenging of applications, including low level PTM analysis, multiplexed relative quantitation using isobaric tags, intact protein characterization, as well as MSn analysis of small molecules with the new Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer. ThisExcel at the most challenging of applications, including low level PTM analysis, multiplexed relative quantitation using isobaric tags, intact protein characterization, as well as MSn analysis of small molecules with the new Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer. This system incorporates the brightest ion source, a segmented quadrupole mass filter with improved selectivity and ion transmission, Advanced Vacuum Technology for improved ion transmission to the Thermo Scientific™ Orbitrap™ mass analyzer, and ETD HD, a higher-capacity ETD fragmentation. Latest innovations include the Advanced Peak Determination (APD) algorithm for improved data-dependent experiments and two new hardware options: UVPD, a new fragmentation technique achieved with a 213 nm UV laser and 1M, which provides 1,000,000 FWHM ultra-high resolution for improved structural elucidation and quantitation of isobaric compounds.... Read More |
Get Quote | | | | | |