Fourier transform infrared (FTIR) microscopes are used in conjunction with FTIR spectroscopy to allow visualization of a sample as an analysis of its components is being done. FTIR microscopes are used in manufacturing for quality control, failure analysis, and reverse engineering and is used in material, forensic, and environmental sciences for surface analysis. As the sample goes through the FTIR spectroscopy, it can be visualized using the microscope inside the spectrometer. The FTIR microscope allows analysis of much smaller samples than FTIR spectroscopy alone, but the sample size can still vary from one FTIR microscope to another. Others features that can differ include fully versus partially automatic and the ability to capture and store images or videos of the samples as the analysis occurs.
Find, compare, and request a quote for FTIR microscopes across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
| | |
Company | JASCO | JASCO |
Item | IRT-5200 FTIR Microscope | IRT-7200 FTIR Microscope |
Citations | | |
Catalog Number | IRT-5200 | IRT-7200 |
Price | | |
Wavelength Range | 7,800 to 600 cm-1 | Single-element mid-band MCT detector: 7,800 to 600 cm-1 1 x 16-element linear array MCT detector: 7,000 to 600 cm-1 |
Signal-to-Noise Ratio | 8000:1 (Aperture size 100 µm2, resolution 4 cm-1, 1 min. acquisition, near 2200 cm-1, p-p) | Single-element mid-band MCT detector: 8000:1 (Aperture size: 100 µm2, Resolution: 4 cm-1, 1 min. acquisition, near 2200 cm-1, p-p) 1 x 16-element linear array MCT detector: 1500:1 (Aperture size: 12.5 µm2, Resolution: 16 cm-1, 1 min. acquisition, near 2200 cm-1, p-p) |
Resolution | 6.25 um2 (32× cassegrain) and 12.5 um2 (16× cassegrain) | 6.25 um2 (32× cassegrain) and 12.5 um2 (16× cassegrain) |
Description | The IRT-5200 FTIR Microscope comes standard with a single-point mid-band MCT detector (7,800 to 600 cm-1). IQ Mapping allows multi-point, line, area and ATR mapping experiments without moving the sample stage, in addition to single-point measurements. An optional automatic XYZ sample stage provides The IRT-5200 FTIR Microscope comes standard with a single-point mid-band MCT detector (7,800 to 600 cm-1). IQ Mapping allows multi-point, line, area and ATR mapping experiments without moving the sample stage, in addition to single-point measurements. An optional automatic XYZ sample stage provides auto-focus and mapping or imaging analysis of larger sample areas. The flexible design of the IRT-5200 allows field upgrades for different measurement capabilities, such as adding an automatic XYZ sample stage for atumoated measurements and mapping analyses of a larger sample area, adding an additional detector, such as a 16-channel linear array MCT detector for dynamic measurements, or adding additional objectives, such as JASCO's ClearView ATR to overlay optical and chemical images.... Read More | The IRT-7200 Linear Array FTIR Imaging Microscope comes standard with two detectors: a single-point mid-band MCT detector (7,800 to 600 cm-1) and a 16-channel linear array MCT detector (7,000 to 650 cm-1), offering a faster response with excellent signal-to-noise and a wider wavelength range than The IRT-7200 Linear Array FTIR Imaging Microscope comes standard with two detectors: a single-point mid-band MCT detector (7,800 to 600 cm-1) and a 16-channel linear array MCT detector (7,000 to 650 cm-1), offering a faster response with excellent signal-to-noise and a wider wavelength range than Focal Plane Array (FPA) detectors. The combination of the standard automatic XYZ sample stage and IQ Mapping allows mapping analyses of a larger sample area, multi-area ATR mapping, and IR imaging of a specified area with extremely high spatial resolution and excellent sensitivity in a short time. The IRT-7100 fully automated FTIR microscope is a more cost-affordable option that is identical to the IRT-7200 Linear Array FTIR microscope, except it only comes standard with a single-point mid-band MCT detector. It is easily field-upgradable to an IR imaging system by adding an optional 16-element linear array detector.... Read More |
Quantity | EA | EA |
Get Quote | | |