Micromanipulator

The analysis of ion channels in membranes, and the ability to inject genes into cells, all require a steady grip that no human hand can supply. Micromanipulators allow the scientist or clinician to accomplish microinjection, patch clamp experiments, extracellular and intra-cellular recordings or precision robotics by carefully controlling microelectrode and syringe movement and capillary flow. Micro-step motors ensure precise movements in three – or even four – dimensions, with resolutions as high as 0.0625 um/step. Stop locks and extra springs ensure minimal drift along the four axes. Some micromanipulator platforms provide central control over four simultaneous manipulators. Though mostly geared toward biochemical applications, a micromanipulator also has uses in micro-electronics and material science. These models tend to have higher thermal and mechanical stability.
CompanySutter InstrumentSutter InstrumentSutter InstrumentSutter InstrumentSutter Instrument
ItemMM-33 / MM-33A MicromanipulatorMP-285 Motorized MicromanipulatorMP-85 Huxley Wall Type MicromanipulatorMPC-365 Narrow Format Manipulator SystemMPC-385 Multi-Manipulator Controller and ROE-200
Citations
(3)
(4)
(2)
Catalog NumberMM-33/R,/L,MM-33-A/R,/LMP-285-R/TMP-85/R,/LMPC-365/-2/-3/-4/-5/-6MPC-385/-2/-3/-4
Price
Full TravelInquire25 mm each axis (1 in)~2 mm on each axis25 mm X-axis, 12.5 mm Y-axis25 mm each axis
Resolution5 µmLow: 0.2um/step, High: 0.04um/step0.1 mm (Coarse), 0.01 mm (Fine), 0.2 µm (Ultrafine)Min. Microstep Size = 62.5 nmMin. Microstep Size = 62.5 nm
Max. SpeedInquire2.9 mm/secInquire3 mm/sec3 to 5 mm/sec (depending on model)
DriftInquireInquireInquireless than 1 micron/hrless than 1 micron/hr
Drive MechanismInquirePrecision Worm Gear Capstan DriveInquireInquireInquire
Description

Used in complex experiments in conjunction with our other micromanipulators, or as a stand alone unit in a teaching environment, the MM-33 is available separately for those wishing a small, practical instrument in applications not requiring submicron accuracy.

The MM-33 is the right choice for

... Read More

The flagship in our line of precision micromanipulators, the motorized MP-285 is affordable yet offers advanced features found in manipulators costing thousands more. Custom engineered stepping motors, precision cross-roller bearing slides and proprietary worm gear capstan drives form the basis of

... Read More

The classic micromanipulator developed by Sir Huxley many years ago is still considered by many investigators to be the finest manual micromanipulator available. The MP-85 offers the advantage of a very large range of movement with its built-in coarse manipulator and precise submicron movement with

... Read More

Our new MP-265/M "narrow format" mechanical is designed especially for patch-slice manipulator systems that require more than 2 or 3 pipettes. Coupled with our multi-manipulator controller, MPC-200, users have the ability to easily build up multi-manipulator MPC-365 systems for positioning multiple

... Read More

Neurobiological experiments are becoming more complex. Many require multiple manipulators with control units that quickly become space and/or cost prohibitive. The MPC-200 is the solution you have been asking for. A single controller capable of running 2 manipulators! Sutter Instrument has taken the

... Read More
Get Quote