The analysis of ion channels in membranes, and the ability to inject genes into cells, all require a steady grip that no human hand can supply. Micromanipulators allow the scientist or clinician to accomplish microinjection, patch clamp experiments, extracellular and intra-cellular recordings or precision robotics by carefully controlling microelectrode and syringe movement and capillary flow. Micro-step motors ensure precise movements in three – or even four – dimensions, with resolutions as high as 0.0625 um/step. Stop locks and extra springs ensure minimal drift along the four axes. Some micromanipulator platforms provide central control over four simultaneous manipulators. Though mostly geared toward biochemical applications, a micromanipulator also has uses in micro-electronics and material science. These models tend to have higher thermal and mechanical stability.
| | | | | |
Company | Sutter Instrument | Sutter Instrument | Sutter Instrument | Sutter Instrument | Sutter Instrument |
Item | MP-85 Huxley Wall Type Micromanipulator | MM-33 / MM-33A Micromanipulator | SOLO Single Axis Manipulator Controller | TRIO™-235 3-axis / 0-90 Diagonal Micromanipulator System | TRIO™-245 3-axis / 0-90 Diagonal Micromanipulator System |
Citations | | | | | |
Catalog Number | MP-85/R,/L | MM-33/R,/L,MM-33-A/R,/L | SOLO-25MM/50MM | TRIO-235 | TRIO-245-L/R |
Price | | | | | |
Full Travel | ~2 mm on each axis | Inquire | Inquire | Inquire | 25 mm on X, Y and Z axes |
Resolution | 0.1 mm (Coarse), 0.01 mm (Fine), 0.2 µm (Ultrafine) | 5 µm | Inquire | Inquire | Inquire |
Max. Speed | Inquire | Inquire | Inquire | Inquire | Inquire |
Drift | Inquire | Inquire | Inquire | Inquire | Inquire |
Drive Mechanism | Inquire | Inquire | Inquire | Inquire | Inquire |
Description | The classic micromanipulator developed by Sir Huxley many years ago is still considered by many investigators to be the finest manual micromanipulator available. The MP-85 offers the advantage of a very large range of movement with its built-in coarse manipulator and precise submicron movement with The classic micromanipulator developed by Sir Huxley many years ago is still considered by many investigators to be the finest manual micromanipulator available. The MP-85 offers the advantage of a very large range of movement with its built-in coarse manipulator and precise submicron movement with the fine controls. Coarse positioning is achieved with a three axis manipulator mounted on top. The ultrafine positioning is accomplished with the large micrometers mounted on the base. These micrometers provide smooth, precise movement through a 10:1 reduction mechanism.
The brass and stainless steel construction of the MP-85 makes for a very heavy and solid micromanipulator with excellent damping properties. This exceptionally stable design is ideal for patch clamp recording, intracellular recording, or any other application that is intolerant of drift.
Please contact Sutter Instrument for any additional information on the suitability and use of the MP-85 micromanipulator for your specific application. Features: MP-85 Dual springing of the moment arms to insure zero backlash and zero torsion. The micromanipulator is mounted on a precision rotating base featuring a positive stop and lock. The coarse movement is an all cross-roller bearing design consisting of coarse X, Y, and Z with an additional fine X motion. The micromanipulator can be ordered in either a right or left handed version.
Options: MP-85 Fifteen degree stackable wedges for tilting the manipulator. A set of three magnetic feet for increased stability. One inch thick, chrome plated, solid brass riser blocks. The MP-85 is chrome-plated and anodized to prevent corrosion. The J.R. Wall designed rotating base is machined from solid stainless steel with a brass spindle; a thin Teflon washer provides for the bearing surface. ... Read More | Used in complex experiments in conjunction with our other micromanipulators, or as a stand alone unit in a teaching environment, the MM-33 is available separately for those wishing a small, practical instrument in applications not requiring submicron accuracy.
The MM-33 is the right choice for Used in complex experiments in conjunction with our other micromanipulators, or as a stand alone unit in a teaching environment, the MM-33 is available separately for those wishing a small, practical instrument in applications not requiring submicron accuracy.
The MM-33 is the right choice for tight environments which require maximum versatility within a small space. The optional rotating base and tiltable X-axis provide even further flexibility.
Stainless steel cross-loaded roller bearings are designed to offer low friction and smooth linear motion with a minimum of side play. The pre-loaded rollers are set at 90 degrees to the hardened steel guides ensuring constant contact and accuracy. This precise rack and pinion drive gives stable, drift free movement with minimal backlash. The controls are placed one above the other which makes for less hand movement and easier positioning. The scales for all axes are calibrated in 0.10mm increments and the fine micrometer adjustment for the X-axis thrust is calibrated at 0.01mm with estimates to 5µm.
The optional rotating base extends the utility of the MM-33 by providing two additional rotating planes. The rotation in the horizontal plane (approximately 120 degrees) has a positive stop, quick release mechanism for fast insertion and removal of pipettes. The second rotating axis allows the MM-33 to be tilted in a vertical plane from 0 to 70 degrees.
The optional tiltable X-axis allows the fine axis to be tilted up to 45 degrees. An optional vertical lock is also available for locking the position of the vertical axis. These options should be ordered at the time of purchase since the modifications are factory installed.
Individual excursions are as follows: X-axis coarse movement: 37mm X-axis fine movement: 10mm Y-axis horizontal movement: 20mm Z-axis vertical movement: 20mm Features: MM-33 Compact design allows use in tight environments. Cross-loaded roller bearings for smooth, low friction movement. Rack and pinion drive gives stable movement with minimal backlash.
Options: MM-33A Rotating base allows horizontal rotation and vertical tilting. Rotating base allows horizontal rotation and vertical tilting. Vertical axis lock. ... Read More | The SOLO is an extremely easy to operate single axis controller capable of running any single axis from Sutter’s line of stepper motor manipulators. The compact design of the SOLO controller requires minimal bench space and provides quiet, fan-free operation.
Features
- Control any single axis from
The SOLO is an extremely easy to operate single axis controller capable of running any single axis from Sutter’s line of stepper motor manipulators. The compact design of the SOLO controller requires minimal bench space and provides quiet, fan-free operation.
Features
- Control any single axis from Sutter stepper motor manipulator collection
- 25 mm or 50 mm length of travel
- Absolute and Relative modes
- User defined Work and Home positions in Absolute mode
- Pulse mode
- USB connectivity
... Read More | The new TRIO™-245 from Sutter Instrument is a highly stable 3-axis manipulator with 25mm of travel on each axis. The TRIO's synthetic 4th axis can be set in software as any angle between 0 and 90 degrees for diagonal movement. Based on a lead-screw design with a smaller overall size and footprint The new TRIO™-245 from Sutter Instrument is a highly stable 3-axis manipulator with 25mm of travel on each axis. The TRIO's synthetic 4th axis can be set in software as any angle between 0 and 90 degrees for diagonal movement. Based on a lead-screw design with a smaller overall size and footprint than most manipulators, the TRIO-245 is ideal for applications that require 2 pipettes in one setup or for setups where space is limited.
Features:- Now available in thermally stable stainless steel
- Three independent axes - 25mm orthogonal travel in X, Y and Z
- Sub-micron (less than 100nm) resolution
- User selectable angle from 0 - 90 degrees via ROE input
- Fast movement with a top speed of 3mm/sec (while homing)
- Mechanically robust construction for high stability
- Compact, fanless, user-friendly ROE controller preserves bench and rack space
- Carries up to a kilogram
- Push button control of multiple functions - WORK, HOME, LOCK, PULSE and RELATIVE
- Suited for in vivo and in vitro electrophysiological recording
- Universal mounting system for headstage or pipette holder
- DIP switches on ROE select direction of movement produced by turn of ROE knob
- USB interface for computer control
... Read More | The TRIO™-245 from Sutter Instrument is a highly stable 3-axis manipulator with 25 mm of travel on each axis. The TRIO's synthetic 4th axis can be set in software as any angle between 0 and 90 degrees for diagonal movement. Based on a lead-screw design with a smaller overall size and footprintThe TRIO™-245 from Sutter Instrument is a highly stable 3-axis manipulator with 25 mm of travel on each axis. The TRIO's synthetic 4th axis can be set in software as any angle between 0 and 90 degrees for diagonal movement. Based on a lead-screw design with a smaller overall size and footprint than most manipulators, the TRIO-245 is ideal for setups where space is limited.
The TRIO-245 controller employs a combination of state-of-the-art software and mechanical design that eliminates the need for the motor to remain powered on during recording, thus eliminating the heating effects of the motors and giving us the electrically quietest manipulators in the industry. This stability ensures that Sutter manipulators will not drift in the middle of experiments.... Read More |
Get Quote | | | | | |