Description | Biotage® SPE Dry 96 and SPE Dry 96 Dual Sample Concentrators are suitable for evaporation of microplate samples across a broad range of formats. By delivering heated gas above and below each well, SPE Dry 96 systems dry samples quickly maintaining tight temperature control at user selected settings.Biotage® SPE Dry 96 and SPE Dry 96 Dual Sample Concentrators are suitable for evaporation of microplate samples across a broad range of formats. By delivering heated gas above and below each well, SPE Dry 96 systems dry samples quickly maintaining tight temperature control at user selected settings. Designed for high throughput sample processing, SPE Dry systems have simple front panel controls and use removable gas delivery assemblies for fast adjusting and cleaning.
Advantages
- Efficient evaporation through heated gas flow above and below collection plate
- Precise temperature control and gas flow with reproducible evaporation times
- Compact design
- Easy to use
- Suitable for 24-, 48-, 96- and 384-well microplates
... Read More | Biotage® PRESSURE+ manifolds deliver positive pressure, parallel processing for 96 well plates, 1 mL 3 mL and 6 mL column formats. The systems utilize a consistent, uniform flow of positive pressure to move both low and high viscosity liquids through SPE plates and columns.
The self-adjusting upperBiotage® PRESSURE+ manifolds deliver positive pressure, parallel processing for 96 well plates, 1 mL 3 mL and 6 mL column formats. The systems utilize a consistent, uniform flow of positive pressure to move both low and high viscosity liquids through SPE plates and columns.
The self-adjusting upper manifold of the Biotage® PRESSURE+96 manifold is compatible with all 96 well plate formats in addition to the popular 1 mL and 2 mL modular array well formats without the need to purchase supplementary gaskets. Biotage collection plates are recommended for the most consistent and reliable results.
Features and Advantages:
- Highly uniform flow from sample to sample for SPE, Protein Precipitation and Supported Liquid Extraction
- Improved reproducibility, accuracy and extraction efficiency, even with viscous samples
- Parallel processing for increased sample throughput
- Easy to set-up and use with just a gas source
- Universal designs accommodate all 96 well plates, or 1 mL, 3 mL and 6 mL SPE columns
- Built-in safety features ensure ease of use and safe operation
... Read More | The Biotage® VacMaster™ Disk is a solid phase extraction system for performing manual, disk-based extractions. The system is designed for high productivity laboratories and is an excellent first step for laboratories interested in moving from liquid-liquid extractions to solid phase extractions for The Biotage® VacMaster™ Disk is a solid phase extraction system for performing manual, disk-based extractions. The system is designed for high productivity laboratories and is an excellent first step for laboratories interested in moving from liquid-liquid extractions to solid phase extractions for sample preparation.... Read More | Sample Processing Manifolds
Biotage® VacMaster™ Sample Processing Manifolds allow up to 10 (VacMaster-10) or 20 (VacMaster-20) SPE or filtration columns to be processed simultaneously under vacuum. Unused ports are sealed when not required. Easy to use vacuum controls provide excellent sample flow Sample Processing Manifolds
Biotage® VacMaster™ Sample Processing Manifolds allow up to 10 (VacMaster-10) or 20 (VacMaster-20) SPE or filtration columns to be processed simultaneously under vacuum. Unused ports are sealed when not required. Easy to use vacuum controls provide excellent sample flow control, leading to reproducible, reliable extraction conditions.
Both systems come complete with glass tank fitted with PTFE waste outlet and drain tube PTFE lid complete with 10 or 20 PTFE needle retainers, stainless steel needles and port sealing plugs. Lid also houses vacuum control arm including on/off valve, fine vacuum control and vacuum release valve. Complete collection tube rack (polyethylene) with 10, 12 or 16 mm collection tube positions (plus 27 mm for VacMaster-10).
Features:
- Save time by processing up to 10 or 20 samples simultaneously
-
Control sample flow individually using the PTFE stopcock option
-
No sample contamination due to inert, solvent resistant components
-
Meet elution volume collection needs with the easy to adjust rack system
-
Thick walled glass tank allows a clear view of the extraction process
-
Generous spacing between columns means all ports can be utilized simultaneously
-
Robust, easy to use vacuum controls are located on the lid, away from solvent and sample contamination
-
Waste can be either collected in the tank, or directed to a suitable trap for disposal
-
All systems fully safety tested at maximum vacuum (-20 \"Hg) to ensure safe, reliable operation
-
Vacuum safety valve fitted as standard to all systems, preventing the maximum operating vacuum being exceeded
... Read More | Sample Processing Manifold
Biotage® VacMaster™-96 sample processing manifold has been designed with the needs of the bioanalytical scientist in mind. This manifold is ideal when processing 96-well SPE, supported liquid extraction or protein precipitation plates either manually or with an automated Sample Processing Manifold
Biotage® VacMaster™-96 sample processing manifold has been designed with the needs of the bioanalytical scientist in mind. This manifold is ideal when processing 96-well SPE, supported liquid extraction or protein precipitation plates either manually or with an automated liquid handling system.
Fully compatible with both fixed well and modular array plate designs from Biotage, Biotage® VacMaster™-96 can also accommodate other brands of 96-well extraction plate using a range of spacers. A wide variety of collection plates can also be used, and cross contamination between wells is minimized by correct use of inserts and spacers in both base and lid, which aid plate positioning.
Automation Friendly
Biotage® VacMaster™-96 is optimized for use with automated liquid handling systems, with features designed to minimize manual intervention. Its lightweight construction allows the lid to easily be manipulated, and the optional standalone vacuum control units mean space requirement on automation decks is minimized. The sloping polypropylene base drains waste quickly out of the manifold base, eliminating the need for a removable waste tray.
Vacuum Control Options
Free standing vacuum control units are available in two formats. Both polypropylene units are equipped with vacuum gauge and fine vacuum controller.
The unique vacuum control and generator unit replaces the need for a vacuum pump. Sufficient vacuum for processing SPE, supported liquid extraction, filtration and protein precipitation plates is generated from a standard laboratory air supply.
Features:
- Increase productivity by processing 96 samples simultaneously
-
Process a range of extraction and collection plates using this versatile, adaptable manifold
-
Reduce steps in automation sequences with the VacMaster-96\'s unique design features
-
Save space at the bench or on instrument decks with the compact, lightweight manifold
... Read More |