Spectrophotometer

Spectrophotometers are used to measure the concentration of a known substance in a solution. They do this by passing a light through the substance and measuring light intensity as a function of wavelength. Either single beam or double beam spectrophotometers can be purchased. In a single beam spectrophotometer, a reference standard is used to measure light intensity before and after the sample is loaded. For double beam spectrophotometers the beam is split with one beam passing through the standard and the other through the sample to compare intensities. While single beam spectrophotometers are typically less expensive and have higher sensitivity, double beam spectrophotometers tend to be more stable and easier to use. Spectrophotometers are important pieces of equipment in chemistry, physics, biochemistry, clinical, and materials testing labs.

Find, compare, and request a quote for spectrophotometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyJASCOJASCOJASCOJASCOJASCO
ItemV-760 UV-Visible SpectrophotometerJ-1500 Circular Dichroism SpectrophotometerJ-1700 Circular Dichroism SpectrophotometerV-770 UV-Vis/NIR SpectrophotometerV-780 UV-Vis/NIR Spectrophotometer
Citations
Figures
(1)
Catalog NumberV-760J-1500J-1700V-770V-780
Price
TypeUV-VisibleCircular DichroismCircular DichroismUV-Visible/NIRUV-Visible/NIR
Wavelength Range187 to 900 nmJ-1500: 163 to 950 nm (Option: 163 to 1600 nm)163 to 2500 nm (Option: 163 to 950 nm (PMT) / Option: 900 to 2500 nm (InGaAs)190 to 2,700 nm (3,200 nm, option)190 to 1,600 nm
Wavelength Accuracy±0.1 nm (at 656.1 nm)InquireInquire±0.3 nm (at 656.1 nm)
± 1.5 nm (at 1312.2 nm)
±0.3 nm (at 656.1 nm)
± 1.0 nm (at 1312.2 nm)
Scanning Speed10 to 4,000 nm/min (8,000 nm/min in preview mode)up to 10,000 nm/minup to 10,000 nm/min10 to 4,000 nm/min (8,000 nm/min in preview mode)10 to 4,000 nm/min (80,00 nm/min in preview mode)
Spectral Bandwidth0.1, 0.2, 0.5, 1, 2, 5, 10 nm
L2, L5, L10 nm (low stray light mode)
M1, M2 nm (micro cell mode)
0.01 to 16 nm0.01 to 16 nm (163 to 950 nm) / 5, 10, 20, 30, 40, 50 nm (950 to 2,500 nm)UV-Vis:
0.1, 0.2, 0.5, 1, 2, 5, 10 nm
L2, L5, L10 nm (low stray light mode)
M1, M2 nm (micro cell mode)
NIR:
0.4, 0.8, 1, 2, 4, 8, 20, 40
L8, L20, L40 nm (low stray light mode)
M4, M8 nm (micro cell mode)
UV-Vis:
0.1, 0.2, 0.5, 1, 2, 5, 10 nm
L2, L5, L10 nm (low stray light mode)
M1, M2 nm (micro cell mode)
NIR:
0.2, 0.4, 0.5, 1, 2, 4, 10, 20
L4, L10, L20 nm (low stray light mode)
M2, M4 nm (micro cell mode)
Optical SystemCzerny-Turner mount
Single monochromator
Fully symmetrical double beam type
Double-prism polarizing monochromator / J-1700: Double-prism polarizing monochromator and grating monochromatorDouble-prism polarizing monochromator and grating monochromatorCzerny-Turner mount
Single monochromator
Fully symmetrical double beam type
Czerny-Turner mount
Single monochromator
Fully symmetrical double beam type
Light SourceHalogen lamp, Deuterium lamp150W air-cooled Xe lamp or 450W water-cooled Xe lamp150W air-cooled Xe lamp or 450W water-cooled Xe lampHalogen lamp, Deuterium lampHalogen lamp, Deuterium lamp
Resolution=BS10Wavelength Resolution: 0.025 nm / CD Resolution: 0.00001 mdegWavelength Resolution: 0.025 nm / CD Resolution: 0.00001 mdeg=BS11=BS12
DescriptionThe V-760 UV-Visible Spectrophotometer includes a double monochromator for exceptional resolution with extremely low stray light (0.00008 %) for more accurate measurement over the widest photometric range (up to 8AU). The V-760 provides excellent sensitivity for diffuse reflectance or transmittance ... Read MoreThe J-1000 Series Circular Dichroism spectrophotometers are specifically designed for high sensitivity measurements in the near- and far-UV regions, for scientists that need confidence in the data from characterization studies of biomolecule structure, function, and stability under a wide variety of... Read MoreThe J-1000 Series Circular Dichroism spectrophotometers are specifically designed for high sensitivity measurements in the near- and far-UV regions, for scientists that need confidence in the data from characterization studies of biomolecule structure, function, and stability under a wide variety of... Read MoreThe V-770 UV-Visible/NIR Spectrophotometer features a unique single monochromator design for maximum light throughput with excellent absorbance linearity. A PMT detector is used for the UV to visible region and a Peltier-cooled PbS detector for the NIR region.The V-780 UV-Visible/NIR Spectrophotometer features a single monochromator with automatically exchanged gratings: 1,200 lines/mm for the UV-Visible region and 600 lines/mm for the NIR region. A PMT detector is used for the UV-Visible region and a high sensitivity InGaAs detector in the NIR region. ... Read More
QuantityEAEAEAEAEA
Get Quote